Automatic spectral calibration for polarization-sensitive optical coherence tomography

被引:8
|
作者
Chen, Yan [1 ,2 ]
Li, Zhongliang [1 ,2 ]
Nan, Nan [1 ,2 ]
Bu, Yang [1 ,2 ]
Wang, Xuan [1 ,2 ]
Pan, Liuhua [1 ,2 ]
Wang, Xiangzhao [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Lab Informat Opt & Optoelect Technol, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
来源
OPTICS EXPRESS | 2017年 / 25卷 / 20期
关键词
HUMAN SKIN; BIREFRINGENCE; RESOLUTION; INTERFEROMETRY; RANGE; OCT;
D O I
10.1364/OE.25.023605
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate wavelength assignment is important for Fourier domain polarization-sensitive optical coherence tomography. Incorrect wavelength mapping between the orthogonal horizontal (H) and vertical (V) polarization channels leads to broadening the axial point spread function and generating polarization artifacts. To solve the problem, we propose an automatic spectral calibration method by seeking the optimal calibration coefficient between wavenumber k(H) and k(V). The method first performs a rough calibration to get the relationship between the wavelength. and the pixel number x of the CCD for each channel. And then a precise calibration is taken to bring both polarization interferograms in the same k range through the optimal calibration coefficient. The optimal coefficient is automatically obtained by evaluating the cross-correlation of A-line signals. Simulations and experiments are implemented to demonstrate the performance of the proposed method. The results show that, compared to the peaks method, the proposed method is suitable in both Gaussian and non-Gaussian spectrums with a higher calibration accuracy. (C) 2017 Optical Society of America
引用
收藏
页码:23605 / 23618
页数:14
相关论文
共 50 条
  • [21] Evaluation of photodamage with polarization-sensitive optical coherence tomography
    Nguyen Hoang Trung
    Lee, Cheng-Yu
    Tsai, Meng-Tsan
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [22] Simplified method for polarization-sensitive optical coherence tomography
    Roth, JE
    Kozak, JA
    Yazdanfar, S
    Rollins, AM
    Izatt, JA
    OPTICS LETTERS, 2001, 26 (14) : 1069 - 1071
  • [23] Polarization-sensitive optical coherence tomography of dental structures
    Baumgartner, A
    Dichtl, S
    Hitzenberger, CK
    Sattmann, H
    Robl, B
    Moritz, A
    Fercher, ZF
    Sperr, W
    CARIES RESEARCH, 2000, 34 (01) : 59 - 69
  • [24] One-camera spectral-domain polarization-sensitive optical coherence tomography
    Baumann, Bernhard
    Pircher, Michael
    Goetzinger, Erich
    Hitzenberger, Christoph K.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [25] Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography
    Yasuno, Y
    Makita, S
    Sutoh, Y
    Itoh, M
    Yatagai, T
    OPTICS LETTERS, 2002, 27 (20) : 1803 - 1805
  • [26] Polarization-sensitive optical coherence tomography with a single input polarization state
    Villiger, Martin
    Xiong, Qiaozhou
    Wang, Nanshuo
    Liu, Xinyu
    Liu, Linbo
    Bouma, Brett E.
    2019 IEEE PHOTONICS CONFERENCE (IPC), 2019,
  • [27] Polarization memory effect in the polarization-sensitive Optical Coherence Tomography system
    Chen, Yueli
    Otis, Linda
    Zhu, Quing
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [28] Suppression of ghost artifacts in polarization-sensitive optical coherence tomography
    Yang, Di
    Wang, Weike
    Xu, Songwen
    Yuan, Zhuoqun
    Chen, Wenguang
    Liang, Yanmei
    OPTICS AND LASER TECHNOLOGY, 2025, 183
  • [29] Determination of burn depth by polarization-sensitive optical coherence tomography
    Srinivas, SM
    de Boer, JF
    Park, H
    Keikhanzadeh, K
    Huang, HEL
    Zhang, J
    Jung, WQ
    Chen, ZP
    Nelson, JS
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 207 - 212
  • [30] Polarization-sensitive optical coherence tomography for ceramic materials inspection
    Trojanowski, M.
    Kraszewski, M.
    Strakowski, M.
    Kosmowski, B. B.
    Plucinski, J.
    PHOTONICS LETTERS OF POLAND, 2014, 6 (04) : 139 - 141