Analytical performance of an ultrasonic particle focusing flow cytometer

被引:72
|
作者
Goddard, Gregory R. [1 ]
Sanders, Claire K. [1 ]
Martin, John C. [1 ]
Kaduchak, Gregory [1 ]
Graves, Steven W. [1 ]
机构
[1] Los Alamos Natl Lab, Natl Flow Cytometry Resource, Los Alamos, NM 87545 USA
关键词
D O I
10.1021/ac071402t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Creation of inexpensive small-flow cytometers is important for applications ranging from disease diagnosis in resource-poor areas to use in distributed sensor networks. In conventional-flow cytometers, hydrodynamics focus particles to the center of a flow stream for analysis, which requires sheath fluid that increases consumable use and waste while dramatically reducing instrument portability. Here we have evaluated, using quantitative measurements of fluorescent microspheres and cells, the performance of a flow cytometer that uses acoustic energy to focus particles to the center of a flow stream. This evaluation demonstrated measurement precision for fluorescence and side scatter CVs for alignment microspheres of 2.54% and 7.7%, respectively. Particles bearing 7 x 10(3) fluorophores were well resolved in a background of 50 nM free fluorophore. The lower limit of detection was determined to be about 650 fluorescein molecules. Analysis of Chinese hamster cells on the system demonstrated that acoustic focusing had no effect on cellular viability. These results indicate that the ultrasonic flow cytometer has the necessary performance for most flow cytometry applications. Furthermore, through robust engineering approaches and the combination of acoustic focusing with low-cost light sources, detectors, and data acquisition systems, it will be possible to achieve a low-cost, truly portable flow cytometer.
引用
收藏
页码:8740 / 8746
页数:7
相关论文
共 50 条
  • [21] Microfluidic impedance spectroscopy flow cytometer: Particle size calibration
    Cheung, K
    Gawad, S
    Renaud, P
    MEMS 2004: 17TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2004, : 343 - 346
  • [22] Toward the Development of an On-Chip Acoustic Focusing Fluorescence Lifetime Flow Cytometer
    Sambrano, Jesus, Jr.
    Rodriguez, Felicia
    Martin, John
    Houston, Jessica P.
    FRONTIERS IN PHYSICS, 2021, 9
  • [23] THE FLOW CYTOMETER
    WYLLIE, AH
    BRITISH MEDICAL JOURNAL, 1987, 294 (6565): : 139 - 139
  • [24] Plastic microchip flow cytometer based on 2- and 3-dimensional hydrodynamic flow focusing
    S. Chung
    S. J. Park
    J. K. Kim
    C. Chung
    D. C. Han
    J. K. Chang
    Microsystem Technologies, 2003, 9 : 525 - 533
  • [25] Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing
    Gawad, S
    Schild, L
    Renaud, P
    LAB ON A CHIP, 2001, 1 (01): : 76 - 82
  • [26] Plastic microchip flow cytometer based on 2-and 3-dimensional hydrodynamic flow focusing
    Chung, S
    Park, SJ
    Kim, JK
    Chung, C
    Han, DC
    Chang, JK
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2003, 9 (08): : 525 - 533
  • [27] Micro flow cytometer with self-aligned 3D hydrodynamic focusing
    Testa, Genni
    Persichetti, Gianluca
    Bernini, Romeo
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (01): : 54 - 62
  • [28] Analytical Capabilities of the ImageStream Cytometer
    Zuba-Surma, Ewa K.
    Ratajczak, Mariusz Z.
    RECENT ADVANCES IN CYTOMETRY, PART A: INSTRUMENTATION, METHODS, FIFTH EDITION, 2011, 102 : 207 - 230
  • [29] Effect of geometrical shapes on 3D hydrodynamic focusing of a microfluidic flow cytometer
    Rahim, Muhammad Syafiq
    Selamat, Norasyikin
    Yunas, Jumril
    Ehsan, Abang Annuar
    2016 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE) PROCEEDINGS, 2016, : 113 - 116
  • [30] Semi analytical finite element analysis for ultrasonic focusing in a pipe
    Hayashi, T
    Kawashima, K
    Sun, ZQ
    Rose, JL
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 22A AND 22B, 2003, 20 : 250 - 255