Changes in anterior chamber depth and intraocular pressure after phacoemulsification and posterior chamber intraocular lens implantation

被引:0
|
作者
Cekic, O [1 ]
Batman, C [1 ]
Totan, Y [1 ]
Emre, I [1 ]
Zilelioglu, O [1 ]
机构
[1] Ankara Hosp, SSK, Eye Clin, Ankara, Turkey
来源
OPHTHALMIC SURGERY AND LASERS | 1998年 / 29卷 / 08期
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To determine anterior chamber depth (ACD) and intraocular pressure (IOP) following uncomplicated cataract extraction with phacoemulsification and posterior chamber intraocular lens (IOL) implantation. PATIENTS AND METHODS: The ACDs and IOPs of 56 patients were prospectively evaluated after phacoemulsification and IOL implantation. Measurements of ACD were performed using ultrasonography and measurements of IOP were performed using a Goldmann applanation tonometer preoperatively and at 1 week and 1, 3, 6, and 3 months postoperatively. RESULTS: The mean IOP had decreased and the mean ACD had increased significantly by 1 month postoperatively (P < .03 and P < .01, respectively). Between 1 and 3 months, a significant increase in ACD (P < .05) and decrease in IOP (P < .01) was also observed. The ACD peaked (3.51 +/- 0.45 mm) and the IOP reached its lowest value (10.05 +/- 2.23 mm Hg) at 3 months postoperatively. The reduction in IOP and increase in ACD remained significant during the follow-up period, compared with the preoperative values. CONCLUSION: These results suggest that increases in ACD and decreases in IOP occur in selected patients after uncomplicated cataract extraction by phacoemulsification with IOL implantation.
引用
收藏
页码:639 / 642
页数:4
相关论文
共 50 条
  • [11] Effects of phacoemulsification on intraocular pressure and anterior chamber depth
    Liu, Xin-Quan
    Zhu, Hua-Ying
    Su, Jing
    Hao, Xiao-Jun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (02) : 507 - 510
  • [12] Early intraocular pressure and anterior chamber depth changes after phacoemulsification and intraocular lens implantation in nonglaucomatous eyes - Comparison of groups stratified by axial length
    Cho, Yang Kyeung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07): : 1104 - 1109
  • [13] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Yi Zhu
    Haobin Zhu
    Yan Jia
    Jibo Zhou
    BMC Ophthalmology, 18
  • [14] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Zhu, Yi
    Zhu, Haobin
    Jia, Yan
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2018, 18
  • [15] Posterior chamber intraocular lens in the anterior chamber
    Zinkernagel, M.
    Ammann-Rauch, D.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2007, 224 (04) : 309 - 310
  • [16] Changes in anterior chamber depth and intraocular pressure after phacoemulsification in eyes with occludable angles
    Shin, Hoy Choong
    Subrayan, Visvaraja
    Tajunisah, Iqbal
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08): : 1289 - 1295
  • [17] Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens
    Takagi, Yuki
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    PLOS ONE, 2020, 15 (11):
  • [18] Intraocular pressure after phacoemulsification with posterior chamber lens implantation in open-angle glaucoma
    Hudovernik, M
    Pahor, D
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (12) : 835 - 839
  • [19] Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
    Hanka Schneider
    Oliver Stachs
    Katja Göbel
    Rudolf Guthoff
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 322 - 329
  • [20] Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
    Schneider, H
    Stachs, O
    Göbel, K
    Guthoff, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (03) : 322 - 329