Decreased gene expression of endothelial nitric oxide synthase in newborns with persistent pulmonary hypertension

被引:61
|
作者
Villanueva, MET
Zaher, FM
Svinarich, DM
Konduri, GG
机构
[1] Hutzel Hosp, Childrens Hosp Michigan, Dept Pediat, Sect Neonatol, Detroit, MI 48201 USA
[2] Wayne State Univ, Sch Med, Detroit, MI USA
[3] CS Mott Ctr Human Growth & Dev, Dept Obstet & Gynecol, Detroit, MI 48201 USA
[4] CS Mott Ctr Human Growth & Dev, Dept Pediat, Detroit, MI 48201 USA
关键词
D O I
10.1203/00006450-199809000-00012
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Previous studies in adults have shown that chronic pulmonary hypertension is associated with decreased endothelial nitric oxide synthase (eNOS) expression in pulmonary arteries. However, the role of decreased eNOS expression in persistent pulmonary hypertension of the newborn (PPHN) is unknown. We investigated the hypothesis that umbilical vein endothelial cells cultured from infants with PPHN will have decreased eNOS expression. Umbilical cords were collected from meconium-stained infants at blah, and endothelial cells were isolated if the infants developed PPHN. Endothelial cells were grown in primary culture, and total RNA was isolated. cDNA was reverse transcribed from mRNA and amplified by PCR. An expected product of approximately 550 bp was found in all control infants but only in two of the six infants with PPHN. Identity of the PCR product was confirmed by Southern hybridization to a separate internal eNOS-specific probe. Amplification of p-actin cDNA, an internal control, was detected in all controls and in all infants with PPHN, including the four infants without the eNOS band. There was no difference in the course and outcome of patients with presence or absence of the eNOS band. However, there was an acidotic arterial blood pH (7.19-7.29) and intrapartum fetal heart rate decelerations in all four infants without eNOS expression. In conclusion, eNOS mRNA was detected in all normal term infants but was notably absent in the majority of infants with PPHN in this pilot study. The development of PPHN is multifactorial, and a decrease in eNOS gene expression may occur in some infants. Whether the decreased eNOS transcript is a cause of PPHN or a result of intrapartum stress remains to be determined.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [21] PULMONARY ENDOTHELIAL NITRIC-OXIDE SYNTHASE GENE-EXPRESSION IS DECREASED IN A RAT MODEL OF CONGENITAL DIAPHRAGMATIC-HERNIA
    NORTH, AJ
    MOYA, FR
    MYSORE, MR
    THOMAS, VL
    WELLS, LB
    WU, LC
    SHAUL, PW
    AMERICAN JOURNAL OF RESPIRATORY CELL AND MOLECULAR BIOLOGY, 1995, 13 (06) : 676 - 682
  • [22] REDUCED EXPRESSION OF ENDOTHELIAL NITRIC-OXIDE SYNTHASE IN THE LUNGS OF PATIENTS WITH PULMONARY-HYPERTENSION
    GIAID, A
    SALEH, D
    NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (04): : 214 - 221
  • [23] Endothelial nitric oxide synthase expression in pulmonary capillary hemangiomatosis
    Kradin, R
    Matsubara, O
    Mark, EJ
    EXPERIMENTAL AND MOLECULAR PATHOLOGY, 2005, 79 (03) : 194 - 197
  • [24] Decreased arteriolar density in endothelial nitric oxide synthase knockout mice is due to hypertension, not to the constitutive defect in endothelial nitric oxide synthase enzyme
    Kubis, N
    Besnard, S
    Silvestre, JS
    Feletou, M
    Huang, PL
    Lévy, BI
    Tedgui, A
    JOURNAL OF HYPERTENSION, 2002, 20 (02) : 273 - 280
  • [25] Selective upregulation of arterial endothelial nitric oxide synthase in pulmonary hypertension
    Resta, TC
    Gonzales, RJ
    Dail, WG
    Sanders, TC
    Walker, BR
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (02): : H806 - H813
  • [26] Is inhaled nitric oxide a miraculous molecule? The analysis of nitric oxide use in newborns with persistent pulmonary hypertension of the newborn
    Srnkova, Patricia
    Brucknerova, Jana
    Brucknerova, Ingrid
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2022, 123 (03): : 153 - 159
  • [27] Relation between endothelial nitric oxide synthase genetic polymorphisms and pulmonary arterial hypertension in newborns with congenital heart disease
    Lin, Qing-Fan
    Rao, Jing-Hong
    Luo, Shi-Mu
    Wang, Qing-Mu
    Deng, Li-Feng
    Chen, Xuan
    Chen, Chang-Di
    Chen, You-Fang
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2022, 44 (06) : 567 - 572
  • [28] Regulation of endothelial nitric oxide synthase activity and gene expression
    Wu, KK
    NITRIC OXIDE: NOVEL ACTIONS, DELETERIOUS EFFECTS AND CLINICAL POTENTIAL, 2002, 962 : 122 - 130
  • [29] Inhaled nitric oxide decreased endothelial nitric oxide synthase expression and activity in newborn rat lungs
    Quy, Sy Duong
    Hua-Huy, Thong
    Kui, Tang Xiao
    Pham-Thi, Hoa
    Pansiot, Julian
    Olivier, Paul
    Olivier, Baud
    Mercier, Jean-Christophe
    Dinh-Xuan, Anh Tuan
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2010, 22 : S9 - S9
  • [30] Right ventricular size is acutely decreased by inhaled nitric oxide in newborns with pulmonary hypertension
    Day, RW
    AMERICAN JOURNAL OF PERINATOLOGY, 1998, 15 (07) : 445 - 451