Signal-to-noise ratio analysis and improvement for fluorescence tomography imaging

被引:6
|
作者
Wang, Huiquan [1 ,2 ,3 ]
Feng, Xing [1 ]
Shi, Boya [1 ,3 ]
Liang, Wenxuan [2 ]
Chen, Yongping [2 ]
Wang, Jinhai [1 ,3 ]
Li, Xingde [2 ]
机构
[1] Tianjin Polytech Univ, Sch Elect & Informat Engn, Tianjin 300387, Peoples R China
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Tianjin Key Lab Optoelect Detect Technol & Syst, Tianjin 300387, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 09期
基金
中国博士后科学基金; 美国国家卫生研究院;
关键词
IN-VIVO; MOLECULAR TOMOGRAPHY; INDOCYANINE GREEN; X-RAY;
D O I
10.1063/1.5045511
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CCD-based fluorescence tomography is widely used for small animal whole-body imaging. In this report, systematic signal-to-noise ratio (SNR) analyses of a fluorescence tomography imaging (FTI) system were performed, resulting in an easy-to-follow strategy to optimize hardware configurations and operational conditions for acquiring high-quality imaging data and for improving the overall system performance. Phantom experiments were conducted to demonstrate the performance improvement by these optimizations. The improved performance was further verified by imaging a tumor-bearing mouse in vivo. This report provides general and practical guidelines for setting up a high-performance electron multiplying charge coupled device based FTI system to achieve an optimized SNR, which can be useful for future FTI technology development. Published by AIP Publishing.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] 'Signal-to-Noise Ratio'
    McCooey, D
    POETRY REVIEW, 1999, 89 (01): : 73 - 73
  • [32] Wavelength Selection for the Improvement of the Signal-to-Noise Ratio for Imaging of Haemoglobin Oxygenation with RGB Reflectometry
    Steimers, Andre
    Steinke, Sarina
    Kohl-Bareis, Matthias
    OXYGEN TRANSPORT TO TISSUE XXXV, 2013, 789 : 405 - 410
  • [33] Imaging Signal-to-Noise Ratio of Synthetic Aperture Ladar
    Liu, Liren
    UNCONVENTIONAL IMAGING AND WAVEFRONT SENSING 2015, 2015, 9617
  • [34] Signal-to-noise ratio limitations for intensity correlation imaging
    Fried, David L.
    Riker, Jim
    Agrawal, Brij
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 2014, 31 (07): : 1536 - 1546
  • [35] Signal-to-noise ratio limitations for intensity correlation imaging
    Fried, David L.
    Riker, Jim
    Agrawal, Brij
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2014, 31 (07) : 1536 - 1546
  • [36] Coded penumbral imaging for improvements of signal-to-noise ratio
    Chen, YW
    Yamamoto, H
    Nozaki, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 4017 - 4019
  • [37] IMAGING THROUGH TURBULENCE - DEGRADATION OF SIGNAL-TO-NOISE RATIO
    WANG, SJ
    PLONUS, MA
    OPTICS COMMUNICATIONS, 1984, 50 (02) : 73 - 78
  • [38] Analysis of signal-to-noise ratio in optical receivers
    Bielecki, Z
    Kolosowski, W
    Sedek, E
    Borejko, M
    TELSIKS 2003: 6TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS IN MODERN SATELLITE, CABLE AND BROADCASTING SERVICE, VOLS 1 AND 2, PROCEEDINGS OF PAPERS, 2003, : 71 - 74
  • [39] Improvement of signal-to-noise ratio of electropherograms and analysis reproducibility with digital signal processing and multiple injections
    Kuldvee, R
    Kaljurand, M
    Smit, HC
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (03): : 169 - 174
  • [40] Measurement of Signal-to-Noise Ratio and Signal-to-Noise and Distortion Ratio Using Histogram Test in Time Domain Analysis
    Jain, Manish
    Sharma, Prakash Chandra
    Tiwari, Pradeep Kumar
    Gupta, Rohit Kumar
    SMART SYSTEMS: INNOVATIONS IN COMPUTING (SSIC 2021), 2022, 235 : 403 - 410