Daylight Discomfort Glare Evaluation with Evalglare: Influence of Parameters and Methods on the Accuracy of Discomfort Glare Prediction

被引:40
|
作者
Pierson, Clotilde [1 ]
Wienold, Jan [2 ]
Bodart, Magali [1 ]
机构
[1] Catholic Univ Louvain, B-1348 Louvain La Neuve, Belgium
[2] Ecole Polytech Fed Lausanne, CH-1015 Lausanne, Switzerland
关键词
evalglare; discomfort glare; glare source detection; glare evaluation; parametric analysis; OPERATING CHARACTERISTIC CURVES; MODEL;
D O I
10.3390/buildings8080094
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, discomfort glare indices are frequently calculated by using evalglare. Due to the lack of knowledge on the implications of the methods and parameters of evalglare, the default settings are often used. But wrong parameter settings can lead to inappropriate glare source detection and therefore to invalid glare indices calculations and erroneous glare classifications. For that reason, this study aims to assess the influence of several glare source detection methods and parameters on the accuracy of discomfort glare prediction for daylight. This analysis uses two datasets, representative of the two types of discomfort glare: saturation and contrast glare. By computing three different statistical indicators to describe the accuracy of discomfort glare prediction, 63 different settings are compared. The results suggest that the choice of an evalglare method should be done when considering the type of glare that is most likely to occur in the visual scene: the task area method should be preferred for contrast glare scenes, and the threshold method for saturation glare scenes. The parameters that should be favored or avoided are also discussed, although a deeper understanding of the discomfort glare mechanism and a clear definition of a glare source would be necessary to reliably interpret these results.
引用
收藏
页数:33
相关论文
共 50 条
  • [21] Discomfort glare evaluation: The influence of anchor bias in luminance adjustments
    Kent, M. G.
    Fotios, S.
    Altomonte, S.
    LIGHTING RESEARCH & TECHNOLOGY, 2019, 51 (01) : 131 - 146
  • [22] INFLUENCE OF PHYSIOLOGICAL FACTORS ON DISCOMFORT GLARE LEVEL
    SAUR, RL
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1969, 46 (05): : 352 - &
  • [23] Quantitative evaluation of the discomfort glare of a tunnel pergola
    Xu, Yu
    Zheng, Xuan
    Hu, Yueqi
    Li, Xue
    Liu, Haoxue
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 95
  • [24] Investigation of Evalglare software, daylight glare probability and high dynamic range imaging for daylight glare analysis
    Suk, J.
    Schiler, M.
    LIGHTING RESEARCH & TECHNOLOGY, 2013, 45 (04) : 450 - 463
  • [25] INFLUENCE OF A GLARE SOURCES SPECTRUM ON DISCOMFORT AND DISABILITY GLARE UNDER MESOPIC CONDITIONS
    Niedling, M.
    Kierdorf, D.
    Voelker, S.
    PROCEEDINGS OF THE CIE CENTENARY CONFERENCE TOWARDS A NEW CENTURY OF LIGHT, 2013, : 340 - 347
  • [26] A study of mechanisms for discomfort glare
    Jia, Y.
    Bargary, G.
    Barbur, J. L.
    PERCEPTION, 2013, 42 : 88 - 89
  • [27] GLARE DISCOMFORT AND PUPIL DIAMETER
    HOPKINSON, RG
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1956, 46 (08) : 649 - 656
  • [28] Disability and discomfort glare of headlamps
    Locher, Jürgen
    Kley, Franziska
    Light and Engineering, 2010, 18 (02): : 30 - 32
  • [29] DISABILITY AND DISCOMFORT GLARE OF HEADLAMPS
    Locher, Juergen
    Kley, Franziska
    LIGHT & ENGINEERING, 2010, 18 (02): : 30 - 32
  • [30] DISCOMFORT GLARE IS TASK DEPENDENT
    SIVAK, M
    FLANNAGAN, M
    ENSING, M
    SIMMONS, CJ
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 1991, 12 (02) : 152 - 159