Calibration of an electron cyclotron emission diagnostic system and electron temperature measurements on HT-7 tokamak

被引:12
|
作者
Sajjad, S. [1 ]
Gao, X. [1 ]
Ling, B. [1 ]
Ti, A. [1 ]
Du, Q. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
关键词
electron cyclotron emission; heterodyne radiometer; electron temperature; optical depth;
D O I
10.1088/0957-0233/19/7/075701
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recently, a broadband heterodyne radiometer has been installed on HT-7 tokamak to measure second harmonic X-mode electron cyclotron emission (ECE) at a frequency range 98 - 126 GHz, which is the only ECE detectable mode with optical depth greater than 1 in the present study. The high temporal resolution (4 mu s) diagnostic system is now operational with 16 detection channels separated by approximately 2 cm on the radial axis for measuring electron temperature (T-e) on the low-field side for typical machine operation at a toroidal magnetic field (B-T) of 1.0 - 2.5 T. The results of electron temperature measurements are presented along with the calibration of the diagnostic system. In order to cross calibrate the ECE system, the electron temperature data obtained have been compared to other Te measuring diagnostics, i.e. Thomson scattering and soft x-ray pulse height analysis (PHA). A radial electron temperature profile during the ohmic heating phase has been presented and analyzed. Future plans for the diagnostics of temperature fluctuations and measurements are also discussed.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Characteristics of the runaway electron beam instability in the HT-7 tokamak
    Chen, Z. Y.
    Zhu, J. X.
    Ju, H. J.
    Du, Q.
    Shi, Y. J.
    Liang, H. F.
    Li, M.
    Cai, W. D.
    JOURNAL OF PLASMA PHYSICS, 2009, 75 : 661 - 667
  • [22] Electron cyclotron emission imaging diagnostic system for Rijnhuizen tokamak project
    Deng, B.H.
    Hsia, R.P.
    Domier, C.W.
    Burns, S.R.
    Hillyer, T.R.
    Luhmann, N.C. Jr.
    Oyevaar, T.
    Donne, A.J.H.
    Review of Scientific Instruments, 1999, 70 (1 pt 2):
  • [23] AC operation and runaway electron behaviour in HT-7 tokamak
    卢洪伟
    胡立群
    周瑞杰
    林士耀
    钟国强
    王少锋
    陈开云
    许平
    张继宗
    凌必利
    毛松涛
    段艳敏
    HT-7 Team
    Chinese Physics B, 2010, 19 (06) : 379 - 388
  • [24] Optical design of ECEI diagnostic system for HT-7 tokamak
    Jun, W
    Wen, YZ
    Yu, CX
    Wan, BN
    Luhmann, NC
    Wang, J
    PLASMA SCIENCE & TECHNOLOGY, 2004, 6 (01) : 2166 - 2171
  • [25] Absolute calibration method of electron cyclotron emission imaging system on EAST tokamak
    Pei Bo-Yang
    Zhuang Ge
    Xie Jin-Lin
    Zhou Yi-Nan
    ACTA PHYSICA SINICA, 2024, 73 (13)
  • [26] Tangential FEB diagnostic in the HT-7 tokamak
    Chen, ZY
    Wan, BN
    Shi, YJ
    Hu, LQ
    Lin, SY
    Ding, YH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 543 (2-3): : 602 - 607
  • [27] Study on thermal transport coefficient of electron in the siliconized HT-7 tokamak
    Zhang, XM
    Wan, BN
    Lu, YC
    Teng, YL
    PLASMA SCIENCE & TECHNOLOGY, 2003, 5 (05) : 1949 - 1954
  • [28] Electron Heat Diffusivity Measurement by Perturbative Method on HT-7 Tokamak
    Du Qin
    Ling Bili
    Ti Ang
    Gao Xiang
    Fei Qinshan
    Sajjad, S.
    Xiong Gang
    PLASMA SCIENCE & TECHNOLOGY, 2008, 10 (06) : 681 - 684
  • [29] Electron thermal transport induced by magnetic turbulence in the HT-7 tokamak
    Zhang, W.
    Xu, G. S.
    Wan, B. N.
    JOURNAL OF NUCLEAR MATERIALS, 2007, 363 (738-742) : 738 - 742
  • [30] Electron Heat Diffusivity Measurement by Perturbative Method on HT-7 Tokamak
    杜勤
    凌必利
    提昂
    高翔
    费勤山
    S.SAJJAD
    熊川
    Plasma Science and Technology, 2008, (06) : 681 - 684