Calibration of an electron cyclotron emission diagnostic system and electron temperature measurements on HT-7 tokamak

被引:12
|
作者
Sajjad, S. [1 ]
Gao, X. [1 ]
Ling, B. [1 ]
Ti, A. [1 ]
Du, Q. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
关键词
electron cyclotron emission; heterodyne radiometer; electron temperature; optical depth;
D O I
10.1088/0957-0233/19/7/075701
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recently, a broadband heterodyne radiometer has been installed on HT-7 tokamak to measure second harmonic X-mode electron cyclotron emission (ECE) at a frequency range 98 - 126 GHz, which is the only ECE detectable mode with optical depth greater than 1 in the present study. The high temporal resolution (4 mu s) diagnostic system is now operational with 16 detection channels separated by approximately 2 cm on the radial axis for measuring electron temperature (T-e) on the low-field side for typical machine operation at a toroidal magnetic field (B-T) of 1.0 - 2.5 T. The results of electron temperature measurements are presented along with the calibration of the diagnostic system. In order to cross calibrate the ECE system, the electron temperature data obtained have been compared to other Te measuring diagnostics, i.e. Thomson scattering and soft x-ray pulse height analysis (PHA). A radial electron temperature profile during the ohmic heating phase has been presented and analyzed. Future plans for the diagnostics of temperature fluctuations and measurements are also discussed.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Electron cyclotron emission diagnostics on HT-7 tokamak
    Sajjad, Sarwar
    Gao, Xiang
    EUROPEAN PHYSICAL JOURNAL D, 2015, 69 (05):
  • [2] Electron cyclotron emission diagnostics on HT-7 tokamak
    Sarwar Sajjad
    Xiang Gao
    The European Physical Journal D, 2015, 69
  • [3] Electron temperature fluctuation in the HT-7 tokamak plasma observed by electron cyclotron emission imaging
    徐小圆
    王俊
    余弈
    闻一之
    俞昌旋
    刘万东
    万宝年
    高翔
    N.C.Luhmann
    C.W.Domier
    王剑
    夏正刚
    申作玮
    ChinesePhysicsB, 2009, 18 (03) : 1153 - 1160
  • [4] Electron temperature fluctuation in the HT-7 tokamak plasma observed by electron cyclotron emission imaging
    Xu Xiao-Yuan
    Wang Jun
    Yu Yi
    Wen Yi-Zhi
    Yu Chang-Xuan
    Liu Wan-Dong
    Wan Bao-Nian
    Gao Xiang
    Luhmann, N. C.
    Domier, C. W.
    Jian Wang
    Xia, Z. G.
    Zuowei Shen
    CHINESE PHYSICS B, 2009, 18 (03) : 1153 - 1160
  • [5] One-Dimensional Vertical Electron Cyclotron Emission Imaging Diagnostic for HT-7 Tokamak
    王俊
    徐小圆
    闻一之
    俞昌旋
    万宝年
    N.C.LUHMANN
    王剑
    夏振刚
    Plasma Science and Technology, 2006, (01) : 76 - 79
  • [6] One-dimensional vertical electron cyclotron emission imaging diagnostic for HT-7 tokamak
    Wang, Jun
    Xu, Xiaoyuan
    Wen, Yizhi
    Yu, Changxuan
    Wan, Baonian
    Luhmann, N. C.
    Wang, Jian
    Xia, Zhengang
    PLASMA SCIENCE & TECHNOLOGY, 2006, 8 (01) : 76 - 79
  • [7] One-Dimensional Vertical Electron Cyclotron Emission Imaging Diagnostic for HT-7 Tokamak
    王俊
    徐小圆
    闻一之
    俞昌旋
    万宝年
    NCLUHMANN
    王剑
    夏振刚
    Plasma Science and Technology, 2006, 8 (01) : 76 - 79
  • [8] A fast-scanning heterodyne radiometer for electron cyclotron emission measurements in HT-7 superconducting tokamak
    Zhang, SY
    Poznyak, VI
    Ploskirev, G
    Kalupin, D
    Wan, YX
    Xie, JK
    Luo, JR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (05): : 2058 - 2061
  • [9] Present Status of the Electron Cyclotron Emission Measurements on HT-7 and EAST
    Liu Yong
    Ti Ang
    Han Xiang
    Wang Yumin
    Li Erzhong
    Ling Bili
    Hu Liqun
    Gao Xiang
    PLASMA SCIENCE & TECHNOLOGY, 2011, 13 (03) : 352 - 356
  • [10] Understanding the bursty electron cyclotron emission during a sawtooth crash in the HT-7 tokamak
    Li, Erzhong
    Hu, Liqun
    Chen, Kaiyun
    PHYSICS OF PLASMAS, 2014, 21 (01)