Rapid Quantification of Myocardial Lipid Content in Humans Using Single Breath-Hold 1H MRS at 3 Tesla

被引:60
|
作者
Rial, Belen [1 ]
Robson, Matthew D. [1 ]
Neubauer, Stefan [1 ]
Schneider, Juergen E. [1 ]
机构
[1] Univ Oxford, Wellcome Trust Ctr Human Genet, Dept Cardiovasc Med, BHF Expt MR Unit, Oxford OX3 7BN, England
关键词
cardiac magnetic resonance spectroscopy; breath-holding; 3; T; lipid; quantification; MAGNETIC-RESONANCE-SPECTROSCOPY; LOCALIZED PROTON SPECTROSCOPY; TYPE-2; DIABETES-MELLITUS; TRIGLYCERIDE CONTENT; CREATINE DEPLETION; DIASTOLIC FUNCTION; PHASED-ARRAY; HUMAN HEART; REPRODUCIBILITY; HEALTHY;
D O I
10.1002/mrm.23011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A rapid, proton magnetic resonance spectroscopy method to evaluate human myocardial lipid levels in a single breath-hold at 3 T using a commercial whole-body system is presented. During a 10 s breath-hold, water unsuppressed and suppressed spectra were acquired by two phased array coils using a short-echo time spectroscopic stimulated echo (STEAM) sequence electrocardiogram-triggered to mid-diastole. Lipid-to-water ratios were obtained in the septum of 15 healthy volunteers, (0.46 +/- 0.19)%. These results agreed well with ratios obtained from averaged spectra acquired in seven multiple breath-holds, (0.45 +/- 0.20)%, providing increased signal-to-noise ratio but requiring longer acquisition times. Excellent correlation was found between the two methods (r = 0.94, P < 0.05). Reproducibility of H-1 MRS for measuring myocardial lipid levels in a short breath-hold was acceptable in five repeated measurements within the same subject (coefficient of variation = 19%). Thus, single breath-hold proton spectroscopy allows reliable and quick quantification of myocardial lipids at 3 T. Magn Reson Med 66:619-624, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 50 条
  • [41] Quantification of vitamin C in the rat brain in vivo using short echo-time 1H MRS
    Terpstra, M
    Tkác, I
    Rao, RL
    Gruetter, R
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 979 - 983
  • [42] 1H-Magnetic Resonance Spectroscopy for Quantifying Myocardial Lipid Content in Humans With the Cardiometabolic Syndrome
    O'Connor, Robert D.
    Bashir, Adil
    Cade, W. Todd
    Yarasheski, Kevin E.
    Gropler, Robert J.
    JOURNAL OF CLINICAL HYPERTENSION, 2009, 11 (09): : 528 - 532
  • [43] Single breath-hold multiarterial dynamic MRI of the liver at 3T using a 3D fat-suppressed keyhole technique
    Hong, Hye-Suk
    Kim, Hua Sun
    Kim, Myeong-Jin
    De Becker, Jan
    Mitchell, Donald G.
    Kanematsu, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (02) : 396 - 402
  • [44] Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
    Ferreira da Silva, Tiago
    Galan-Arriola, Carlos
    Montesinos, Paula
    Lopez-Martin, Gonzalo Javier
    Desco, Manuel
    Fuster, Valentin
    Ibanez, Borja
    Sanchez-Gonzalez, Javier
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (06) : 865 - 876
  • [45] Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
    Tiago Ferreira da Silva
    Carlos Galan-Arriola
    Paula Montesinos
    Gonzalo Javier López-Martín
    Manuel Desco
    Valentín Fuster
    Borja Ibáñez
    Javier Sanchez-Gonzalez
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 865 - 876
  • [46] Reproducibility of relaxometry of human lumbar vertebrae at 3 Tesla using 1H MR spectroscopy
    Neumayer, Bernhard
    Widek, Thomas
    Stollberger, Rudolf
    Scheurer, Eva
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (01) : 153 - 159
  • [47] Dynamic interleaved 1H/31P STEAM MRS at 3 Tesla using a pneumatic force-controlled plantar flexion exercise rig
    M. Meyerspeer
    M. Krššák
    G. J. Kemp
    M. Roden
    E. Moser
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 257 - 262
  • [48] Time-resolved early-to-late Gadolinium enhancement MRI using single breath-hold 3D spiral imaging
    Taehoon Shin
    Dwight G Nishimura
    Michael V McConnell
    Bob S Hu
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [49] Detection of early enhancement of hypervascular hepatocellular carcinoma using single breath-hold 3D pixel shift dynamic subtraction MDCT
    Nakaura, Takeshi
    Awai, Kazuo
    Yanaga, Yumi
    Nakayama, Yoshiharu
    Oda, Seitaro
    Funama, Yoshinori
    Yamashita, Yasuyuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) : W13 - W18
  • [50] Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition
    Chen, Weitian
    Chan, Queenie
    Wang, Yi-Xiang J.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (02) : 168 - 177