Rapid Quantification of Myocardial Lipid Content in Humans Using Single Breath-Hold 1H MRS at 3 Tesla

被引:60
|
作者
Rial, Belen [1 ]
Robson, Matthew D. [1 ]
Neubauer, Stefan [1 ]
Schneider, Juergen E. [1 ]
机构
[1] Univ Oxford, Wellcome Trust Ctr Human Genet, Dept Cardiovasc Med, BHF Expt MR Unit, Oxford OX3 7BN, England
关键词
cardiac magnetic resonance spectroscopy; breath-holding; 3; T; lipid; quantification; MAGNETIC-RESONANCE-SPECTROSCOPY; LOCALIZED PROTON SPECTROSCOPY; TYPE-2; DIABETES-MELLITUS; TRIGLYCERIDE CONTENT; CREATINE DEPLETION; DIASTOLIC FUNCTION; PHASED-ARRAY; HUMAN HEART; REPRODUCIBILITY; HEALTHY;
D O I
10.1002/mrm.23011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A rapid, proton magnetic resonance spectroscopy method to evaluate human myocardial lipid levels in a single breath-hold at 3 T using a commercial whole-body system is presented. During a 10 s breath-hold, water unsuppressed and suppressed spectra were acquired by two phased array coils using a short-echo time spectroscopic stimulated echo (STEAM) sequence electrocardiogram-triggered to mid-diastole. Lipid-to-water ratios were obtained in the septum of 15 healthy volunteers, (0.46 +/- 0.19)%. These results agreed well with ratios obtained from averaged spectra acquired in seven multiple breath-holds, (0.45 +/- 0.20)%, providing increased signal-to-noise ratio but requiring longer acquisition times. Excellent correlation was found between the two methods (r = 0.94, P < 0.05). Reproducibility of H-1 MRS for measuring myocardial lipid levels in a short breath-hold was acceptable in five repeated measurements within the same subject (coefficient of variation = 19%). Thus, single breath-hold proton spectroscopy allows reliable and quick quantification of myocardial lipids at 3 T. Magn Reson Med 66:619-624, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 50 条
  • [1] Breath-Hold 1H-Magnetic Resonance Spectroscopy for Intrahepatic Lipid Quantification at 3 Tesla
    Bredella, Miriam A.
    Ghomi, Reza Hosseini
    Thomas, Bijoy J.
    Ouellette, Hugue A.
    Sahani, Dushyant V.
    Miller, Karen K.
    Torriani, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (03) : 372 - 376
  • [2] Retrogated spiral 3-directional myocardial phase velocity mapping in a single breath-hold
    Robin Simpson
    Jennifer Keegan
    Peter D Gatehouse
    David N Firmin
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [3] Retrogated spiral 3-directional myocardial phase velocity mapping in a single breath-hold
    Robin Simpson
    Jennifer Keegan
    Peter D Gatehouse
    David N Firmin
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [4] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Marcus R Makowski
    Andrea J Wiethoff
    Christian HP Jansen
    Sergio Uribe
    Victoria Parish
    Andreas Schuster
    Rene M Botnar
    Aaron Bell
    Christoph Kiesewetter
    Reza Razavi
    Tobias Schaeffter
    Gerald F Greil
    Journal of Cardiovascular Magnetic Resonance, 14
  • [5] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Makowski, Marcus R.
    Wiethoff, Andrea J.
    Jansen, Christian H. P.
    Uribe, Sergio
    Parish, Victoria
    Schuster, Andreas
    Botnar, Rene M.
    Bell, Aaron
    Kiesewetter, Christoph
    Razavi, Reza
    Schaeffter, Tobias
    Greil, Gerald F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [6] Single Breath-Hold T1ρ-Mapping of the Heart for Endogenous Assessment of Myocardial Fibrosis
    van Oorschot, Joep W. M.
    Visser, Fredy
    Eikendal, Anouk L. M.
    Vonken, Evert-jan P. A.
    Luijten, Peter R.
    Chamuleau, Steven A. J.
    Leiner, Tim
    Zwanenburg, Jaco J. M.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (08) : 505 - 512
  • [7] Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysis
    Young, Alistair A.
    Cowan, Brett R.
    Schoenberg, Stefan O.
    Wintersperger, Bernd J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [8] Feasibility of single breath-hold left ventricular function with 3 Tesla TSENSE acquisition and 3D modeling analysis
    Alistair A Young
    Brett R Cowan
    Stefan O Schoenberg
    Bernd J Wintersperger
    Journal of Cardiovascular Magnetic Resonance, 10
  • [9] Single breath-hold 3D LGE using stack of spiral trajectory
    Yang Yang
    Peter Shaw
    Jorge A Gonzalez
    Christopher M Kramer
    Michael Salerno
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [10] Monitoring response to breast cancer treatment using 4 tesla 1H MRS
    Baker, E
    DelaBarre, L
    Bolan, PJ
    Merkle, H
    Everson, LI
    Garwood, M
    RADIOLOGY, 2001, 218 (02) : 609 - 609