Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors

被引:14
|
作者
Elman, Noel M. [1 ,2 ,3 ]
Ben-Yoav, Hadar [2 ]
Sternheim, Marek [3 ]
Rosen, Rachel [5 ]
Krylov, Slava [4 ]
Shacham-Diamand, Yosi [2 ,3 ]
机构
[1] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
[2] Tel Aviv Univ, Fac Engn, Dept Elect Engn Phys Elect, IL-69978 Ramat Aviv, Israel
[3] Tel Aviv Univ, Univ Res Inst NanoSci & NanoTechnol, IL-69978 Ramat Aviv, Israel
[4] Tel Aviv Univ, Fac Engn, Dept Solid Mech Mat & Syst, IL-69978 Ramat Aviv, Israel
[5] Hebrew Univ Jerusalem, Dept Plant Sci, IL-91904 Jerusalem, Israel
来源
BIOSENSORS & BIOELECTRONICS | 2008年 / 23卷 / 11期
关键词
whole-cell sensors; bioluminescence; toxicity; environmental toxicity; water toxicity; MOEMS; MEMS; modulator; optical modulation; lab-on-chip; solid-state shoto-detectors;
D O I
10.1016/j.bios.2008.01.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-D-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02 mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1631 / 1636
页数:6
相关论文
共 50 条
  • [41] Integrated chemiluminescence-based lab-on-chip for detection of life markers in extraterrestrial environments
    Nascetti, Augusto
    Mirasoli, Mara
    Marchegiani, Elisa
    Zangheri, Martina
    Costantini, Francesca
    Porchetta, Alessandro
    Iannascoli, Lorenzo
    Lovecchio, Nicola
    Caputo, Domenico
    de Cesare, Giampiero
    Pirrotta, Simone
    Roda, Aldo
    BIOSENSORS & BIOELECTRONICS, 2019, 123 : 195 - 203
  • [42] Integration of Impedimetric Sensors for In Situ Electrochemical Impedance Spectroscopy in Free-Flow Electrophoresis Applications in Lab-on-Chip Systems
    Haensch, Tobias
    Zitzmann, Franziska D.
    Jahnke, Heinz-Georg
    Blaha, Maximilian E.
    Paternoga, Erik
    Zeitler, Kirsten
    Belder, Detlev
    Robitzki, Andrea A.
    ACS SENSORS, 2022, 7 (12) : 3906 - 3914
  • [43] Authentication of Primary Murine Cell Lines by a Microfluidics-Based Lab-On-Chip System
    Hong, Yingfen
    Singh, Nikita
    Bamopoulos, Stefanos
    Gjerga, Enio
    Schmalbrock, Laura K.
    Balabanian, Karl
    Schick, Markus
    Keller, Ulrich
    Wirth, Matthias
    BIOMEDICINES, 2020, 8 (12) : 1 - 13
  • [44] Quantitative detection of dengue serotypes using a smartphone-connected handheld lab-on-chip platform
    Moser, Nicolas
    Yu, Ling-Shan
    Manzano, Jesus Rodriguez
    Malpartida-Cardenas, Kenny
    Au, Anselm
    Arkell, Paul
    Cicatiello, Chiara
    Moniri, Ahmad
    Miglietta, Luca
    Wang, Wen-Hung
    Wang, Sheng Fan
    Holmes, Alison
    Chen, Yen-Hsu
    Georgiou, Pantelis
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [45] Uniform droplet splitting and detection using Lab-on-Chip flow cytometry on a microfluidic PDMS device
    Kunstmann-Olsen, Casper
    Hanczyc, Martin M.
    Hoyland, James
    Rasmussen, Steen
    Rubahn, Horst-Gunter
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 229 : 7 - 13
  • [46] Rapid and multiplex detection of nosocomial pathogens on a phage-based magnetoresistive lab-on-chip platform
    Cunha, Alexandra P.
    Henriques, Raquel
    Cardoso, Susana
    Freitas, Paulo P.
    Carvalho, Carla M.
    BIOTECHNOLOGY AND BIOENGINEERING, 2021, 118 (08) : 3164 - 3174
  • [47] Rapid whole-cell sensing chip for low-level arsenite detection
    Chiou, Chi-Han
    Chien, Liang-Ju
    Chou, Tsung-Che
    Lin, Jr-Lung
    Tseng, Joseph T.
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2484 - 2488
  • [48] Development of an Electrochemiluminescence-based Lab-on-Chip Using Thin/Thick Film Technologies
    Lovecchio, Nicola
    Costantini, Francesca
    Nascetti, Augusto
    Petrucci, Rita
    de Cesare, Giampiero
    Caputo, Domenico
    2019 IEEE 8TH INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES (IWASI), 2019, : 79 - 83
  • [49] Whole-cell screening of oxidative enzymes using genetically encoded sensors
    Kardashliev, Tsvetan
    Weingartner, Alexandra
    Romero, Elvira
    Schwaneberg, Ulrich
    Fraaije, Marco
    Panke, Sven
    Held, Martin
    CHEMICAL SCIENCE, 2021, 12 (44) : 14766 - 14772
  • [50] An Allee-based distributed algorithm for microbial whole-cell sensors
    Cravo, Fabricio
    Fugger, Matthias
    Nowak, Thomas
    NPJ SYSTEMS BIOLOGY AND APPLICATIONS, 2024, 10 (01)