Low cost amorphous silicon based 160 x 120 uncooled microbolometer 2D array for high volume applications

被引:6
|
作者
Tissot, JL [1 ]
Astier, A [1 ]
Chatard, JP [1 ]
Tinnes, S [1 ]
Trouilleau, C [1 ]
Yon, JJ [1 ]
机构
[1] ULIS, F-38113 Veurey Voroize, France
关键词
uncooled IRFPA; 2D array; microbolometer; amorphous silicon; vacuum package;
D O I
10.1117/12.488383
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Uncooled infrared focal plane arrays are being developed for a wide range of thermal imaging applications. Developments are focused on the improvement of their sensitivity enabling the possibility to reduce the pixel pitch in order to decrease the total system by using smaller optics. We present the characterization of a 160 x 120 infrared focal plane array with a pixel pitch of 35 mum. The amorphous silicon technology is the latest one developed by CEA/LETI and transferred to ULIS to manufacture 160 x 120 2D arrays. We developed for this device a low cost package based on existing technologies. The readout integrated circuit structure is using an advanced skimming function to enhance the pixel signal exploitation. This device is well adapted to high volume process control applications where spatial resolution is less important than device costs. The electro-optical characterization is presented.
引用
收藏
页码:511 / 517
页数:7
相关论文
共 50 条
  • [31] Design and fabrication of a high-density 2D fiber array for holographic switching applications
    Letort, Cedric
    Vinouze, Bruno
    Fracasso, Bruno
    OPTICAL ENGINEERING, 2008, 47 (04)
  • [32] 2D MXenes: Synthesis, Properties, and Applications in Silicon-Based Optoelectronic Devices
    Li, Wei
    Xu, Zhiyuan
    Yan, Yu
    Gao, Qianfeng
    Song, Yaya
    Wang, Taiqiang
    Dun, Hongyu
    Yang, Mingyu
    Huang, Qian
    Zhang, Xiaodan
    Zhao, Ying
    Hou, Guofu
    SMALL, 2025, 21 (09)
  • [33] Low Cost 2D Laser Scanner Based Indoor Mapping and Classification System
    Jafri, Syed Riaz Un Nabi
    Amjad, Hira
    Sultan, Moazza
    Khan, Hashim Raza
    2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION IN INDUSTRY (ICRAI), 2019,
  • [34] Novel X-ray silicon detector for 2D imaging and high resolution spectroscopy
    Castoldi, A
    Gatti, E
    Guazzoni, C
    Longoni, A
    Rehak, P
    Strüder, L
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 240 - 248
  • [35] 3D Laser Imaging Method based on Low Cost 2D Laser Radar
    Xu, Xiaobin
    Pei, Ronghao
    Luo, Minzhou
    Tan, Zhiying
    THREE-DIMENSIONAL IMAGE ACQUISITION AND DISPLAY TECHNOLOGY AND APPLICATIONS, 2018, 10845
  • [36] Characterization of 2D high-speed photodetector array device for SDM fiber communication applications
    Kusakata, K.
    Takamizawa, S.
    Umezawa, T.
    Yamamoto, N.
    Kawanishi, T.
    2019 24TH OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC) AND 2019 INTERNATIONAL CONFERENCE ON PHOTONICS IN SWITCHING AND COMPUTING (PSC), 2019,
  • [37] In vivo liver tracking with a high volume rate 4D ultrasound scanner and a 2D matrix array probe
    Bell, Muyinatu A. Lediju
    Byram, Brett C.
    Harris, Emma J.
    Evans, Philip M.
    Bamber, Jeffrey C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1359 - 1374
  • [38] Recent progress in optoelectronic applications of hybrid 2D/3D silicon-based heterostructures
    Zhou, Jingshu
    Xin, Kaiyao
    Zhao, Xiangkai
    Li, Dongmei
    Wei, Zhongming
    Xia, Jianbai
    SCIENCE CHINA-MATERIALS, 2022, 65 (04) : 876 - 895
  • [39] 2D X-ray Focusing Device Based on Silicon Planar Refractive Lenses
    Sorokovikov, M. N.
    Zverev, D. A.
    Barannikov, A. A.
    Astafyev, A. L.
    Panormov, I. B.
    Yunkin, V. A.
    Seregin, A. Y.
    Volkovskiy, Y. A.
    Prosekov, P. A.
    Snigirev, A. A.
    NANOBIOTECHNOLOGY REPORTS, 2024, 19 (SUPPL1) : S183 - S190
  • [40] A Low-RCS 2D Multi-Layer Van Atta Array at X-Band
    Chen, Lei
    Qin, Mingjuan
    Zou, Lin
    Zhang, Tianling
    ELECTRONICS, 2023, 12 (16)