Development of Energy Benchmarks for Office Buildings Using the National Energy Consumption Database

被引:8
|
作者
Kim, Hye Gi [1 ]
Kim, Sun Sook [1 ]
机构
[1] Ajou Univ, Dept Architecture, Suwon 16499, South Korea
基金
新加坡国家研究基金会;
关键词
building energy benchmarking; energy performance benchmark; existing building; office building; PERFORMANCE;
D O I
10.3390/en13040950
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In an effort to improve the energy efficiency of existing buildings, it is necessary to first evaluate the energy performance of those buildings. Since it is difficult to obtain detailed information on existing buildings, the challenge is how to conduct reliable energy performance assessments with this limited information. As a result, many countries have adopted evaluation systems based on measured energy consumption data for existing buildings. This study aims to analyze the building energy consumption and characteristics using Korea's national building database and provide an energy performance benchmark for continuous management of the energy performance of existing buildings. We analyzed the relationship between the basic statistical characteristics of the information collected from the national integrated energy database and energy consumption. The total floor area was found to be closely related to energy consumption, and various regression analysis methods were applied and compared to develop a benchmark to explain the trends of energy consumption according to the increase in total floor area. Finally, the developed benchmarks were used to evaluate energy consumption and examine the feasibility of the benchmarks.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] The reality and statistical distribution of energy consumption in office buildings in China
    Xiao, He
    Wei, Qingpeng
    Jiang, Yi
    ENERGY AND BUILDINGS, 2012, 50 : 259 - 265
  • [22] Evaluation of Energy Consumption With Energyplus Simulation in Office Existing Buildings
    Ratnasari, Listiyani Desy
    Sangadji, Senot S. T. M. T.
    Safitri, Endah S. T. M. T.
    INTERNATIONAL CONFERENCE ON SCIENCE AND APPLIED SCIENCE (ICSAS2020), 2020, 2296
  • [23] Study of the potential savings on energy demand and HVAC energy consumption by using coated glazing for office buildings in Madrid
    Cordoba, J
    Macias, M
    Espinosa, JM
    ENERGY AND BUILDINGS, 1998, 27 (01) : 13 - 19
  • [24] ENERGY CONSUMPTION REDUCTION IN OFFICE BUILDINGS USING MODEL-BASED PREDICTIVE CONTROL
    Lepore, Renato
    Renotte, Christine
    Frere, Marc
    Dumont, Eric
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 2459 - 2465
  • [25] Simulating future energy consumption in office buildings using an ensemble of morphed climate data
    Troup, Luke
    Eckelman, Matthew J.
    Fannon, David
    APPLIED ENERGY, 2019, 255
  • [26] Development of a Metamodel to Predict Cooling Energy Consumption of HVAC Systems in Office Buildings in Different Climates
    Lopes, Mauricio Nath
    Lamberts, Roberto
    SUSTAINABILITY, 2018, 10 (12)
  • [27] Development of new baseline models for US medium office buildings based on commercial buildings energy consumption survey data
    Ye, Yunyang
    Lou, Yingli
    Strong, Matthew
    Upadhyaya, Satish
    Zuo, Wangda
    Wang, Gang
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (09) : 1321 - 1336
  • [28] Correction and Evaluation of Energy Consumption for Office Buildings Based on Use Intensity
    Weng J.
    Zhao K.
    Ge J.
    Ying X.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (11): : 260 - 266
  • [29] Energy consumption in typical Caribbean office buildings: A potential short term solution to energy concerns
    Edwards, Erwin Elliot
    Iyare, O. S.
    Moseley, L. L.
    RENEWABLE ENERGY, 2012, 39 (01) : 154 - 161
  • [30] The impact of cool roofs on energy consumption of office buildings in Chongqing of China
    Gao, Ya-Feng
    Zhao, Kai
    Su, Bin
    Wang, Zhi-Qiang
    Tang, Xiao-Min
    Open Construction and Building Technology Journal, 2015, 9 (01): : 142 - 146