Morphological analysis of proximal contacts in class II direct restorations with 3D image reconstruction

被引:26
|
作者
Chuang, Shu-Fen [1 ,3 ]
Su, Kuo-Chih [2 ]
Wang, Chun-Hsiang [3 ]
Chang, Chih-Han [2 ]
机构
[1] Natl Cheng Kung Univ, Inst Oral Med, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 701, Taiwan
[3] Natl Cheng Kung Univ Hosp, Dept Stomatol, Tainan 704, Taiwan
关键词
Resin composite; Proximal contact; Morphology; 3D scan; RESIN COMPOSITE RESTORATIONS; RANDOMIZED CLINICAL-TRIAL; PLACEMENT TECHNIQUE; TOOTH CONTACT; TIGHTNESS; SYSTEMS;
D O I
10.1016/j.jdent.2011.04.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the proximal contact on class II composite restorations constructed using various restorative approaches by a morphological analysis. Methods: Sixty plastic premolar teeth were prepared for class II cavities. These teeth were divided into six groups and restored using different materials and matrix systems. Two composite materials used were a microhybrid composite Filtek Z100 (3M/ESPE) and a packable composite P60 (3M/ESPE). Three interproximal matrix systems were two circumferential metal matrices (0.05 mm and 0.03 mm thin, respectively) combined with a Tofflemire retainer, and a pre-contoured sectional matrix system (Palodent). The contact morphologies of the restorations were visually inspected with regard to their buccolinugal and mesiodistal aspects. The contact tightness was measured by inserting different amounts of metal strips. For quantitatively morphologic analysis, three-dimensional (3D) scans of proximal contacts were performed. The results were analysed with two-way ANOVA and the Tukey test. Results: Under visual observation, contact surfaces in sectional matrix groups showed anatomic profile but concave in the centre, whilst the circumferential matrix groups showed flat profiles. The sectional matrix improved the contact tightness. The 3D analysis revealed that the matrix system was correlated with the contact morphology, since the sectional matrix generated significantly deeper and wider surface concavity. Conclusions: All the interproximal matrix systems presented some deficiency in either the contact tightness or contours. Although the sectional matrix system enhanced contact tightness, it caused contact concavity by formation of interproximal marginal overhang. The quantitative morphologic analysis helps to examine improper proximal contact and the associated problems. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:448 / 456
页数:9
相关论文
共 50 条
  • [41] Image alignment for 3D reconstruction in a SEM
    Pintus, R
    Podda, S
    Vanzi, M
    MICROELECTRONICS RELIABILITY, 2005, 45 (9-11) : 1581 - 1584
  • [42] 3D Reconstruction from A Single Image
    Ping, Guiju
    Wang, Han
    PROCEEDINGS OF THE IEEE 2019 9TH INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (CIS) ROBOTICS, AUTOMATION AND MECHATRONICS (RAM) (CIS & RAM 2019), 2019, : 47 - 52
  • [43] Morphological Characterization of Agglomerated Particles by 3D Reconstruction
    Zavala, J. P.
    Isaza, C.
    Anaya, E. K.
    Castillo, E.
    IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (07) : 3117 - 3123
  • [44] Accelerated 3D image reconstruction with a morphological pyramid and noise-power convergence criterion
    Sisniega, A.
    Stayman, J. W.
    Capostagno, S.
    Weiss, C. R.
    Ehtiati, T.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [45] Error estimation of 3D reconstruction in 3D digital image correlation
    Zhu, Chengpeng
    Yu, Shanshan
    Liu, Cong
    Jiang, Pengfei
    Shao, Xinxing
    He, Xiaoyuan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (02)
  • [46] Passive 3D Face Reconstruction with 3D Digital Image Correlation
    Kieu, Hien
    Wang, Zhaoyang
    Le, Minh
    Nguyen, Hieu
    ADVANCEMENT OF OPTICAL METHODS IN EXPERIMENTAL MECHANICS, VOL 3, 2015, : 403 - 407
  • [47] 3d optical profilometer analysis of the marginal gap of class ii restorations made with different materials for vital pulp therapy procedures
    Salerno, Marco (marco.salerno@iit.it), 1600, Japanese Society for Dental Materials and Devices (40):
  • [48] 3D optical profilometer analysis of the marginal gap of Class II restorations made with different materials for vital pulp therapy procedures
    Salerno, Marco
    Vizza, Francesca
    Amaroli, Andrea
    Signore, Antonio
    Itri, Angelo
    DENTAL MATERIALS JOURNAL, 2021, 40 (02) : 407 - 415
  • [49] Local analysis for 3D reconstruction of specular surfaces - Part II
    Savarese, S
    Perona, P
    COMPUTER VISION - ECCV 2002, PT II, 2002, 2351 : 759 - 774
  • [50] Image segmentation and image matching for 3D terrain reconstruction
    Lu, YH
    Kubik, K
    Bennamoun, M
    FOURTEENTH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1 AND 2, 1998, : 1535 - 1537