Morphological analysis of proximal contacts in class II direct restorations with 3D image reconstruction

被引:26
|
作者
Chuang, Shu-Fen [1 ,3 ]
Su, Kuo-Chih [2 ]
Wang, Chun-Hsiang [3 ]
Chang, Chih-Han [2 ]
机构
[1] Natl Cheng Kung Univ, Inst Oral Med, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 701, Taiwan
[3] Natl Cheng Kung Univ Hosp, Dept Stomatol, Tainan 704, Taiwan
关键词
Resin composite; Proximal contact; Morphology; 3D scan; RESIN COMPOSITE RESTORATIONS; RANDOMIZED CLINICAL-TRIAL; PLACEMENT TECHNIQUE; TOOTH CONTACT; TIGHTNESS; SYSTEMS;
D O I
10.1016/j.jdent.2011.04.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the proximal contact on class II composite restorations constructed using various restorative approaches by a morphological analysis. Methods: Sixty plastic premolar teeth were prepared for class II cavities. These teeth were divided into six groups and restored using different materials and matrix systems. Two composite materials used were a microhybrid composite Filtek Z100 (3M/ESPE) and a packable composite P60 (3M/ESPE). Three interproximal matrix systems were two circumferential metal matrices (0.05 mm and 0.03 mm thin, respectively) combined with a Tofflemire retainer, and a pre-contoured sectional matrix system (Palodent). The contact morphologies of the restorations were visually inspected with regard to their buccolinugal and mesiodistal aspects. The contact tightness was measured by inserting different amounts of metal strips. For quantitatively morphologic analysis, three-dimensional (3D) scans of proximal contacts were performed. The results were analysed with two-way ANOVA and the Tukey test. Results: Under visual observation, contact surfaces in sectional matrix groups showed anatomic profile but concave in the centre, whilst the circumferential matrix groups showed flat profiles. The sectional matrix improved the contact tightness. The 3D analysis revealed that the matrix system was correlated with the contact morphology, since the sectional matrix generated significantly deeper and wider surface concavity. Conclusions: All the interproximal matrix systems presented some deficiency in either the contact tightness or contours. Although the sectional matrix system enhanced contact tightness, it caused contact concavity by formation of interproximal marginal overhang. The quantitative morphologic analysis helps to examine improper proximal contact and the associated problems. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:448 / 456
页数:9
相关论文
共 50 条
  • [1] Clinical evaluation of proximal contacts of Class II esthetic direct restorations
    Prakki, A
    Cilli, R
    Saad, JOC
    Rodrigues, JR
    QUINTESSENCE INTERNATIONAL, 2004, 35 (10): : 785 - 789
  • [2] Use of Transparent Tips for Obtaining Tight Proximal Contacts in Direct Class II Composite Resin Restorations
    Alonso, V
    Caserio, M.
    Darriba, I. L.
    OPERATIVE DENTISTRY, 2019, 44 (05) : 446 - 451
  • [3] Comparison of proximal contacts of class II resin composite restorations in vitro
    Loomans, B. A. C.
    Opdam, N. J. M.
    Roeters, F. J. M.
    Bronkhorst, E. M.
    Burgersdijk, R. C. W.
    OPERATIVE DENTISTRY, 2006, 31 (06) : 688 - 693
  • [4] Achieving tight contacts in class II direct resin restorations
    Kaplowitz, GJ
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (07): : 1012 - 1013
  • [5] Direct 3D PET Image Reconstruction into MR Image Space
    Gravel, Paul
    Verhaeghe, Jeroen
    Reader, Andrew J.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3955 - 3962
  • [6] SEM-analysis of tooth-colored direct class II restorations with proximal margins located in dentin
    Bott, B
    Hannig, M
    Moller, O
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1103 - 1103
  • [7] Software for 3D diagnostic image reconstruction and analysis
    Taton, Grzegorz
    Rokita, Eugeniusz
    Sierzega, Marek
    Klek, Stanislaw
    Kulig, Jan
    Urbanik, Andrzej
    POLISH JOURNAL OF RADIOLOGY, 2005, 70 (03) : 64 - 72
  • [8] Clinical Effectiveness of Direct Class II Restorations - A Meta-Analysis
    Heintze, Siegward D.
    Rousson, Valentin
    JOURNAL OF ADHESIVE DENTISTRY, 2012, 14 (05): : 407 - 431
  • [9] Surgically Relevant Morphological Parameters of Proximal Human Femur: A Statistical Analysis Based on 3D Reconstruction of CT Data
    Soodmand, Ehsan
    Zheng, Guoyan
    Steens, Wolfram
    Bader, Rainer
    Nolte, Lutz
    Kluess, Daniel
    ORTHOPAEDIC SURGERY, 2019, 11 (01) : 135 - 142
  • [10] 3D genome reconstruction from chromosomal contacts
    Lesne, Annick
    Riposo, Julien
    Roger, Paul
    Cournac, Axel
    Mozziconacci, Julien
    NATURE METHODS, 2014, 11 (11) : 1141 - 1143