Dual-reference full-range frequency domain optical coherence tomography

被引:2
|
作者
Lee, Kye-Sung [1 ]
Meemon, Panomsak [1 ]
Hsu, Kevin [2 ]
Dallas, William [3 ]
Rolland, Jannick P. [4 ]
机构
[1] Univ Cent Florida, CREOL, Coll Opt & Photon, 4000 Cent Florida Blvd, Orlando, FL 32816 USA
[2] Micron Opt Inc, Atlanta, GA 30345 USA
[3] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[4] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
基金
美国国家科学基金会;
关键词
Fourier-domain optical coherence tomography; Dual-reference full range optical coherence tomography; SPECTRAL-DOMAIN;
D O I
10.1117/12.823146
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It has been shown that frequency domain optical coherence tomography (FD-OCT) systems achieve higher sensitivities compared to time domain OCT systems. However, the obscure object structure due to the mirror image generated by the Fourier transform is one of the main problems in FD-OCT. We designed and developed a novel full range FD-OCT system that we refer to as the dual-reference full-range FD-OCT (DR-FDOCT) that enables doubling the imaging depth by removing mirror images generated from the Fourier transform of the detected real-valued spectra. The DR-FDOCT system enables full-range imaging without any loss of speed and is less sensitive to phase errors generated by involuntary movements of the subject than the other established full-range OCT systems. The reason is because it uses two signals with a phase difference of pi/2 obtained simultaneously from two reference arms to remove mirror images.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Measurement of Thickness and Refractive Index of Optical Samples Simultaneously Using Full-Range One-Shot Frequency-Domain Optical Coherence Tomography
    Cheng, Hsu-Chih
    Huang, Chia-Tsai
    FIBER AND INTEGRATED OPTICS, 2015, 34 (03) : 171 - 182
  • [32] Sample motion-insensitive, full-range, complex, spectral-domain optical-coherence tomography
    Zotter, Stefan
    Pircher, Michael
    Goetzinger, Erich
    Torzicky, Teresa
    Bonesi, Marco
    Hitzenberger, Christoph K.
    OPTICS LETTERS, 2010, 35 (23) : 3913 - 3915
  • [33] Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography
    An, Lin
    Wang, Ruikang K.
    OPTICS LETTERS, 2007, 32 (23) : 3423 - 3425
  • [34] Full-range Fourier domain polarization-sensitive optical coherence tomography using sinusoidal phase modulation
    Chen, Yan
    Wang, Xiangzhao
    Li, Zhongliang
    Nan, Nan
    Guo, Xin
    TWELFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2014), 2014, 9230
  • [35] Full Range, Dual Depth Optical Coherence Tomography for Ophthalmology
    Kim, Beop-Min
    Jeong, Hyun-Woo
    Kim, Jeehyun
    Lee, Sang-Won
    Chung, Wonzoo
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [36] Dynamic full-range Fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    OPTICAL ENGINEERING, 2007, 46 (10)
  • [37] Full-range parallel Fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2007, 9 (04): : 422 - 426
  • [38] Full-range Fourier domain optical coherence tomography imaging probe with a magnetic-driven resonant fiber cantilever
    Zhang, Kang
    Huang, Yong
    Kang, Jin U.
    OPTICAL ENGINEERING, 2011, 50 (11)
  • [39] Extended in vivo anterior eye-segment imaging with full-range complex spectral domain optical coherence tomography
    Jungwirth, Johannes
    Baumann, Bernhard
    Pircher, Michael
    Goetzinger, Erich
    Hitzenberger, Christoph K.
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
  • [40] Microcirculation imaging based on full-range high-speed spectral domain correlation mapping optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin J.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (02)