Clinical trial of telepathology as an alternative modality in breast histopathology quality assurance

被引:32
|
作者
Leong, FJWM
Graham, AK
Schwarzmann, P
McGee, JO
机构
[1] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Pathol & Bacteriol, Oxford OX3 9DU, England
[2] Univ Stuttgart, Inst Phys Elekt, D-70569 Stuttgart, Germany
来源
TELEMEDICINE JOURNAL AND E-HEALTH | 2000年 / 6卷 / 04期
关键词
D O I
10.1089/15305620050503834
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Telepathology is a potential alternative to conventional histopathology. A clinical trial using a robotic telepathology system was conducted to assess the clinical and technical utility and effectiveness of telepathology in the U.K. breast screening pathology quality assurance program. Eighty-seven cases of breast disease were chosen at random from a series of 192 cases from the U.K. Breast Screening Pathology National Quality Assurance Scheme (NEQAS) collection. There were 20 benign, 23 carcinoma in situ (CIS), and 44 invasive malignant cases. The diagnostic accuracy of telepathology (TP) compared with conventional light microscopic (LM) diagnosis was 98.8%; this included a single case deferred for LM examination. The figure was similar when compared with expert consensus diagnosis (CD). In invasive tumor typing, TP accuracy was 95.4% (42/44 cases), the difference being attributable to slide color fading and would have had no impact on patient management. The accuracy of TP versus LM and expert consensus in tumor grading was 91.3% for carcinoma in situ (21/23 cases), a discordance with no relevance to patient management. TP grading of invasive tumor compared with LM diagnosis, had an accuracy of 86.4% (38/44) with a clinically significant accuracy of 97.7% (43/44). The time taken for TP diagnosis averaged 3.9 minutes per case by the end of the study. This data demonstrates that telepathology diagnostic accuracy is comparable to conventional microscopy and may therefore be envisaged as an alternative to conventional light microscopy for more rapid proficiency testing in breast screening (and perhaps other) quality assurance schemes.
引用
收藏
页码:373 / 377
页数:5
相关论文
共 50 条
  • [41] The Impact of Clinical Trial Quality Assurance on Outcome in Head and Neck Radiotherapy Treatment
    Zhong, Haoyu
    Men, Kuo
    Wang, Jiazhou
    van Soest, Johan
    Rosenthal, David
    Dekker, Andre
    Zhang, Zhen
    Xiao, Ying
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [42] Impact of radiotherapy clinical trial participation and quality assurance on head and neck practice
    Tyler, Justine
    Baines, Helen
    Clark, Catharine
    Eyles, Hannah
    Miles, Elizabeth
    Nabi, Zohal
    Simoes, Rita
    Webster, Amanda
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S2684 - S2687
  • [43] Quality assurance of brachytherapy for supratentorial glioma in a multi-institutional clinical trial
    Deutsch, M
    Blackwood, M
    Selker, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1911 - 1911
  • [44] Global clinical trials: Quality assurance methodology for site based, global clinical trial ratings
    Spear, C.
    Busner, J.
    Vieta, E.
    Bartko, J.
    Bealer, R.
    INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2008, 11 : 311 - 311
  • [45] QUALITY ASSURANCE IN CLINICAL BIOCHEMISTRY
    FRASER, CG
    PROCEEDINGS OF THE ROYAL SOCIETY OF EDINBURGH SECTION B-BIOLOGICAL SCIENCES, 1993, 101 : 251 - 261
  • [46] Quality assurance in clinical trials
    Ottevanger, PB
    Therasse, P
    van de Velde, C
    Bernier, J
    van Krieken, H
    Grol, R
    De Mulder, P
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2003, 47 (03) : 213 - 235
  • [47] Quality assurance for malaria clinical trial microscopy based on theoretical and empirical evidence
    Chretien, Jean-Paul
    Prudhomme, Wendy
    Awuondo, Ken
    Tang, Doug
    Remich, Shon
    Ogutu, Bernard
    Nanakorn, Ampon
    Ohrt, Colin
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2005, 73 (06): : 200 - 200
  • [48] ALTERNATIVE CONSTRUCTION QUALITY ASSURANCE PROGRAMS - CLOSURE
    HESTER, WT
    JOURNAL OF THE ENVIRONMENTAL ENGINEERING DIVISION-ASCE, 1980, 106 (06): : 1208 - 1208
  • [49] ALTERNATIVE CONSTRUCTION QUALITY ASSURANCE PROGRAMS - DISCUSSION
    SNELL, LM
    JOURNAL OF THE CONSTRUCTION DIVISION-ASCE, 1980, 106 (02): : 235 - 236
  • [50] Quality assurance in clinical dosimetry
    Bardies, Manuel
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 : 14 - 14