Smart Stylet: The Development and Use of a Bedside External Ventricular Drain Image-Guidance System

被引:11
|
作者
Patil, Vaibhav [1 ]
Gupta, Rajiv [3 ]
Estepar, Raul San Jose [1 ]
Lacson, Ronilda [1 ]
Cheung, Arnold [3 ]
Wong, Judith M. [2 ]
Popp, A. John [2 ]
Golby, Alexandra [1 ,2 ]
Ogilvy, Christopher [4 ]
Vosburgh, Kirby G. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Neurosurg, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[4] Beth Israel Deaconess Med Ctr, Dept Neurosurg, Boston, MA 02215 USA
关键词
Ventriculostomy; Image-guided surgery; Electromagnetic concepts; Neuronavigation; FRAMELESS STEREOTACTIC SYSTEMS; CATHETER PLACEMENT; PEDIATRIC-PATIENTS; RISK-FACTORS; ACCURACY; NAVIGATION; HYDROCEPHALUS; TRACKING; MONITOR;
D O I
10.1159/000368906
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Placement accuracy of ventriculostomy catheters is reported in a wide and variable range. Development of an efficient image-guidance system may improve physician performance and patient safety. Objective: We evaluate the prototype of Smart Stylet, a new electromagnetic image-guidance system for use during bedside ventriculostomy. Methods: Accuracy of the Smart Stylet system was assessed. System operators were evaluated for their ability to successfully target the ipsilateral frontal horn in a phantom model. Results: Target registration error across 15 intracranial targets ranged from 1.3 to 4.6 mm (mean 3.1 mm). Using Smart Stylet guidance, a test operator successfully passed a ventriculostomy catheter to a shifted ipsilateral frontal horn 20/20 (100%) times from the frontal approach in a skull phantom. Without Smart Stylet guidance, the operator was successful 4/10 (40%) times from the right frontal approach and 6/10 (60%) times from the left frontal approach. In a separate experiment, resident operators were successful 2/4 (50%) times when targeting the shifted ipsilateral frontal horn with Smart Stylet guidance and 0/4 (0%) times without image guidance using a skull phantom. Conclusions: Smart Stylet may improve the ability to successfully target the ventricles during frontal ventriculostomy. (C) 2015 S. Karger AG, Basel
引用
收藏
页码:50 / 58
页数:9
相关论文
共 50 条
  • [21] Use of frameless neuronavigation for bedside placement of external ventricular catheters
    Glenn, Chad A.
    Conner, Andrew K.
    Cheema, Ahmed A.
    Burks, Joshua D.
    Case, Justin L.
    O'Neal, Christen
    Sughrue, Michael E.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 26 : 132 - 135
  • [22] Image-guidance technology: What type of information best guides its appropriate use?
    Marple, Bradley F.
    Setzen, Michael
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2006, 135 (01) : 73 - 75
  • [23] The Impact of Nursing Education on Emergency Bedside External Ventricular Drain Insertion for Patients With Acute Hydrocephalus
    Alomar, Soha A.
    Bandah, Sara T.
    Noman, Gaida A.
    Kadi, Mai
    Abulnaja, Ghada A.
    Abdullah, Ghadah
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [24] A wearable mixed-reality holographic computer for guiding external ventricular drain insertion at the bedside
    Li, Ye
    Chen, Xiaolei
    Wang, Ning
    Zhang, Wenyao
    Li, Dawei
    Zhang, Lei
    Qu, Xin
    Cheng, Weitao
    Xu, Yueqiao
    Chen, Wenjin
    Yang, Qiumei
    JOURNAL OF NEUROSURGERY, 2019, 131 (05) : 1599 - 1606
  • [25] Ultrasound and Fluoroscopy Based Intraoperative Image-Guidance System for Dynamic Dosimetry in Prostate Brachytherapy
    Kuo, N.
    Dehghan, E.
    Le, Y.
    Deguet, A.
    Burdette, E.
    Fichtinger, G.
    Prince, J.
    Song, D.
    Lee, J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [26] Augmented Reality Surgical Navigation System for External Ventricular Drain
    Chiou, Shin-Yan
    Zhang, Zhi-Yue
    Liu, Hao-Li
    Yan, Jiun-Lin
    Wei, Kuo-Chen
    Chen, Pin-Yuan
    HEALTHCARE, 2022, 10 (10)
  • [27] Offline generator for digitally reconstructed radiographs of a commercial stereoscopic radiotherapy image-guidance system
    Charters, John A.
    Bertram, Pascal
    Lamb, James M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [28] An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy
    Kuo, Nathanael
    Dehghan, Ehsan
    Deguet, Anton
    Mian, Omar Y.
    Le, Yi
    Burdette, E. Clif
    Fichtinger, Gabor
    Prince, Jerry L.
    Song, Danny Y.
    Lee, Junghoon
    MEDICAL PHYSICS, 2014, 41 (09)
  • [29] Does the use of an antibacterial external ventricular drain increase the risk of resistance?
    Gagori Bandopadhyay
    Waheed Ashraf
    Juliet Clayton
    Rohit Sinha
    Roger Bayston
    Donald MacArthur
    Cerebrospinal Fluid Research, 6 (Suppl 1):
  • [30] Development of dedicated phantom for end-to-end testing of multiple image-guidance configurations incorporating light-section-based surface guidance system
    Hayashi, Naoki
    Saito, Tatsunori
    Ouchi, Kazuki
    Amma, Hiroshi
    Muraki, Yuta
    Yasui, Keisuke
    Nozue, Masashi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):