Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT

被引:19
|
作者
Kortelainen, Matti J. [1 ,2 ]
Koivumaki, Tuomas M. [2 ,3 ]
Vauhkonen, Marko J. [2 ]
Hakulinen, Mikko A. [1 ,2 ]
机构
[1] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio 70029, Finland
[2] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[3] Kuopio Univ Hosp, Ctr Canc, Kuopio 70029, Finland
关键词
Gated SPECT; myocardial perfusion imaging: SPECT; left ventricular function; phase analysis; acquisition time; EMISSION COMPUTED-TOMOGRAPHY; PHASE-ANALYSIS; EJECTION FRACTION; MECHANICAL DYSSYNCHRONY; TEMPORAL RESOLUTION; PROGNOSTIC VALUE; RECONSTRUCTION; QUALITY; CONTRACTION; ALGORITHM;
D O I
10.1007/s12350-015-0178-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reduction of image acquisition time in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) examinations has been considered. However, association between left ventricular (LV) functional parameters and acquisition time is unclear. Twenty-four patients referred to one-day stress/rest SPECT MPI examinations were imaged at rest with dual-headed gamma camera. List-mode emission data were processed into sets of cardiac-gated images corresponding to different acquisition times: 20%, 30%, 40%, 50%, 60%, 80%, and 100% of total acquisition time (30 seconds per projection). Image quality was quantitatively evaluated by computing contrast-to-noise ratio. LV volumes, wall motion, wall thickening, and mechanical dyssynchrony were quantified with automatic clinical software (QGS; Cedars-Sinai Medical Center). A significant negative dependence was found between phase analysis parameter values and image acquisition time. Differences in LV volume parameters were small but statistically significant at relative acquisition times of less than 50%. LV wall motion and wall thickening were found to be robust to the increase of noise. Image acquisition time of gated SPECT MPI examination can be reduced to 15 seconds per projection without significantly affecting LV volumes, wall motion, or wall thickening. However, reduction of acquisition time has a significant effect on phase analysis results.
引用
收藏
页码:643 / 651
页数:9
相关论文
共 50 条
  • [21] Myocardial perfusion and left ventricular function indices assessed by gated myocardial perfusion SPECT in methamphetamine abusers
    Dadpour, Bita
    Kakhki, Vahid R. Dabbagh
    Afshari, Reza
    Dorri-giv, Masoumeh
    Mohajeri, Seyed A. R.
    Ghahremani, Somayeh
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (12) : 1302 - 1305
  • [22] Left ventricular ejection fraction: Gated blood pool SPECT versus myocardial perfusion gated SPECT.
    Daou, D
    Coaguila, C
    Vilain, D
    Lebtahi, R
    Benelhadj, S
    Fourme, T
    Colin, P
    Idy-Peretti, I
    Slama, M
    Le Guludec, D
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 97P - 97P
  • [23] Myocardial perfusion and left ventricular quantitative parameters obtained using gated myocardial SPECT: Comparison of three software packages
    Alexiou, Sotiria
    Georgoulias, Panagiotis
    Angelidis, George
    Valotassiou, Varvara
    Tsougos, Ioannis
    Psimadas, Dimitrios
    Lakiotis, Velissarios
    Kaspiri, Agaristi
    Alexopoulos, Dimitrios
    Apostolopoulos, Dimitrios
    Vassilakos, Pavlos
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (03) : 911 - 924
  • [24] Myocardial perfusion and left ventricular quantitative parameters obtained using gated myocardial SPECT: Comparison of three software packages
    Sotiria Alexiou
    Panagiotis Georgoulias
    George Angelidis
    Varvara Valotassiou
    Ioannis Tsougos
    Dimitrios Psimadas
    Velissarios Lakiotis
    Agaristi Kaspiri
    Dimitrios Alexopoulos
    Dimitrios Apostolopoulos
    Pavlos Vassilakos
    Journal of Nuclear Cardiology, 2018, 25 : 911 - 924
  • [25] Gated SPECT beyond myocardial perfusion: assessment of mechanical left ventricular synchrony
    Erick Alexánderson-Rosas
    Salvador Hernández-Sandoval
    Journal of Nuclear Cardiology, 2022, 29 : 975 - 977
  • [26] Validation of left ventricular volumes automatically measured with gated myocardial perfusion SPECT
    Germano, G
    Vandecker, W
    Mintz, R
    Ogilby, D
    Wolf, N
    Berman, D
    Iskandrian, AE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 43A - 43A
  • [27] Gated SPECT beyond myocardial perfusion: assessment of mechanical left ventricular synchrony
    Alexanderson-Rosas, Erick
    Hernandez-Sandoval, Salvador
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (03) : 975 - 977
  • [28] Determination of occult left-ventricular dysfunction by gated myocardial perfusion SPECT
    Malhotra, S
    Nichols, K
    DePuey, EG
    Cohen, R
    Rozanski, A
    CIRCULATION, 1996, 94 (08) : 1403 - 1403
  • [29] Left ventricular ejection fraction in gated myocardial perfusion, a comparison of SPECT and IQ-SPECT
    de Jong, A. N.
    Akkermans, J. B. M.
    Van Asperen, E. A.
    Snoijs, C. H. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S601 - S601
  • [30] Gated myocardial perfusion SPECT for evaluating left ventricular dyssynchrony in cardiac resynchronization therapy candidates: a systematic review
    Stepien-Wroniecka, Agnieszka
    Dziewiecka, Ewa
    Graczyk, Katarzyna
    Holcman, Katarzyna
    Winiarczyk, Mateusz
    Przytula, Natalia
    Kostkiewicz, Magdalena
    Podolec, Piotr
    Rubis, Pawel