Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT

被引:19
|
作者
Kortelainen, Matti J. [1 ,2 ]
Koivumaki, Tuomas M. [2 ,3 ]
Vauhkonen, Marko J. [2 ]
Hakulinen, Mikko A. [1 ,2 ]
机构
[1] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio 70029, Finland
[2] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[3] Kuopio Univ Hosp, Ctr Canc, Kuopio 70029, Finland
关键词
Gated SPECT; myocardial perfusion imaging: SPECT; left ventricular function; phase analysis; acquisition time; EMISSION COMPUTED-TOMOGRAPHY; PHASE-ANALYSIS; EJECTION FRACTION; MECHANICAL DYSSYNCHRONY; TEMPORAL RESOLUTION; PROGNOSTIC VALUE; RECONSTRUCTION; QUALITY; CONTRACTION; ALGORITHM;
D O I
10.1007/s12350-015-0178-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reduction of image acquisition time in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) examinations has been considered. However, association between left ventricular (LV) functional parameters and acquisition time is unclear. Twenty-four patients referred to one-day stress/rest SPECT MPI examinations were imaged at rest with dual-headed gamma camera. List-mode emission data were processed into sets of cardiac-gated images corresponding to different acquisition times: 20%, 30%, 40%, 50%, 60%, 80%, and 100% of total acquisition time (30 seconds per projection). Image quality was quantitatively evaluated by computing contrast-to-noise ratio. LV volumes, wall motion, wall thickening, and mechanical dyssynchrony were quantified with automatic clinical software (QGS; Cedars-Sinai Medical Center). A significant negative dependence was found between phase analysis parameter values and image acquisition time. Differences in LV volume parameters were small but statistically significant at relative acquisition times of less than 50%. LV wall motion and wall thickening were found to be robust to the increase of noise. Image acquisition time of gated SPECT MPI examination can be reduced to 15 seconds per projection without significantly affecting LV volumes, wall motion, or wall thickening. However, reduction of acquisition time has a significant effect on phase analysis results.
引用
收藏
页码:643 / 651
页数:9
相关论文
共 50 条
  • [1] Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT
    Matti J. Kortelainen
    Tuomas M. Koivumäki
    Marko J. Vauhkonen
    Mikko A. Hakulinen
    Journal of Nuclear Cardiology, 2015, 22 : 643 - 651
  • [2] Left ventricular functional parameters by gated SPECT myocardial perfusion imaging in a Latin American country
    Kapitan, Miguel
    Beltran, Alvaro
    Beretta, Mario
    Mut, Fernando
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (02) : 652 - 660
  • [3] Left ventricular functional parameters by gated SPECT myocardial perfusion imaging in a Latin American country
    Miguel Kapitan
    Alvaro Beltran
    Mario Beretta
    Fernando Mut
    Journal of Nuclear Cardiology, 2018, 25 : 652 - 660
  • [4] Repeatability of left ventricular dyssynchrony and function parameters in serial gated myocardial perfusion SPECT
    Lin, Xianhe
    Faber, Tracy
    Garcia, Ernest
    Soman, Prem
    Chen, Ji
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [5] Gated myocardial perfusion SPECT: Effect of patient position on left ventricular functional indices
    Kakhki, V. Dabbagh
    Beiki, D.
    Fallahi, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S311 - S311
  • [6] Effect of data conserving respiratory motion compensation on left ventricular functional parameters assessed in gated myocardial perfusion SPECT
    Kortelainen, Matti J.
    Koivumaki, Tuomas M.
    Vauhkonen, Marko J.
    Hakulinen, Mikko A.
    EJNMMI PHYSICS, 2021, 8 (01)
  • [7] Effect of data conserving respiratory motion compensation on left ventricular functional parameters assessed in gated myocardial perfusion SPECT
    Matti J Kortelainen
    Tuomas M Koivumäki
    Marko J Vauhkonen
    Mikko A Hakulinen
    EJNMMI Physics, 8
  • [8] Normal limits of left ventricular function parameters from myocardial perfusion gated spect.
    Nichols, K
    Rozanski, A
    Malhotra, S
    Cohen, R
    DePuey, EG
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 410 - 410
  • [9] Repeatability of left ventricular dyssynchrony and function parameters in serial gated myocardial perfusion SPECT studies
    Xianhe Lin
    Huiqin Xu
    Xuefeng Zhao
    Russell D. Folks
    Ernest V. Garcia
    Prem Soman
    Ji Chen
    Journal of Nuclear Cardiology, 2010, 17 : 811 - 816
  • [10] Repeatability of left ventricular dyssynchrony and function parameters in serial gated myocardial perfusion SPECT studies
    Lin, Xianhe
    Xu, Huiqin
    Zhao, Xuefeng
    Folks, Russell D.
    Garcia, Ernest V.
    Soman, Prem
    Chen, Ji
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (05) : 811 - 816