Even 100 years after Dr. Roentgen's detection, the basic X-ray tube design is nearly unchanged. A broad spectrum of poly-energetic X-rays is generated by deceleration of electrons in heavy metal, superimposed by the characteristic fluorescence lines of that material. Several physical effects, e.g. absorption and scattering, are energy-depending. A mono-energetic source, like a radio-nuclide, offers several advantages for numerous applications. An X-ray source combining mono-energetic radiation with the benefits of a switchable electrical device will be outlined. The major properties like spectral purity, stability and radiance will be presented followed by an outlook of potential application areas, especially in NDT.
引用
收藏
页码:1297 / 1300
页数:4
相关论文
共 50 条
  • [41] X-ray measurements of black hole X-ray binary source GRS 1915+105 and the evolution of hard X-ray spectrum
    Manchanda, RK
    JOURNAL OF ASTROPHYSICS AND ASTRONOMY, 2000, 21 (1-2) : 39 - 52
  • [42] X-ray measurements of black hole X-ray binary source GRS 1915+105 and the evolution of hard X-ray spectrum
    R. K. Manchanda
    Journal of Astrophysics and Astronomy, 2000, 21 : 39 - 52
  • [43] THE ENERGETIC CHARACTERISTICS OF THE X-RAY PHOTOCATHODES
    PROKHOROV, AM
    CHEVOKIN, VK
    SHCHEMELEV, VN
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1990, 52 : 529 - 539
  • [44] Measurements of relative x-ray line intensities and their application to a single standard procedure for quantitative x-ray microanalysis
    Hatzistergos, M. S.
    Lifshin, E.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (12)
  • [45] Measurements of relative x-ray line intensities and their application to a single standard procedure for quantitative x-ray microanalysis
    Hatzistergos, M.S.
    Lifshin, E.
    Journal of Applied Physics, 2006, 100 (12):
  • [46] Performance measurements of the DIXI (dilation x-ray imager) photocathode using a laser produced x-ray source
    Nagel, Sabrina R.
    Ayers, M. J.
    Felker, B.
    Hilsabeck, T. J.
    Chung, T.
    Smith, R. F.
    Bell, P. M.
    Bradley, D. K.
    Collins, G. W.
    Kilkenny, J. D.
    Sammuli, B.
    Hares, J. D.
    Dymoke-Bradshaw, A. K. L.
    TARGET DIAGNOSTICS PHYSICS AND ENGINEERING FOR INERTIAL CONFINEMENT FUSION, 2012, 8505
  • [47] A pulsed, mono-energetic and angular-selective UV photo-electron source for the commissioning of the KATRIN experiment
    J. Behrens
    P. C.-O. Ranitzsch
    M. Beck
    A. Beglarian
    M. Erhard
    S. Groh
    V. Hannen
    M. Kraus
    H.-W. Ortjohann
    O. Rest
    K. Schlösser
    T. Thümmler
    K. Valerius
    K. Wierman
    J. F. Wilkerson
    D. Winzen
    M. Zacher
    C. Weinheimer
    The European Physical Journal C, 2017, 77
  • [48] Quantitative measurements of diesel fuel spray characteristics in the near-nozzle region using X-ray absorption
    Yue, Y
    Powell, CF
    Poola, R
    Wang, J
    Schaller, JK
    ATOMIZATION AND SPRAYS, 2001, 11 (04) : 471 - 490
  • [49] A pulsed, mono-energetic and angular-selective UV photo-electron source for the commissioning of the KATRIN experiment
    Behrens, J.
    Ranitzsch, P. C. -O.
    Beck, M.
    Beglarian, A.
    Erhard, M.
    Groh, S.
    Hannen, V.
    Kraus, M.
    Ortjohann, H. -W.
    Rest, O.
    Schloesser, K.
    Thuemmler, T.
    Valerius, K.
    Wierman, K.
    Wilkerson, J. F.
    Winzen, D.
    Zacher, M.
    Weinheimer, C.
    EUROPEAN PHYSICAL JOURNAL C, 2017, 77 (06):
  • [50] Near-Edge X-Ray Absorption Fine Structure Measurements Using a Laser Plasma XUV Source
    Peth, C.
    Barkusky, F.
    Sedlmair, J.
    Gleber, S-C.
    Novakova, E.
    Niemeyer, J.
    Thieme, J.
    Salditt, T.
    Mann, K.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186