An Enhanced Fault Ride-Through Capability for MTDC Systems Using Vector Current Control and Inherent Energy of Submodules of MMC

被引:2
|
作者
Ansari, Jamshed Ahmed [1 ]
Liu, Chongru [1 ]
Zheng, Le [1 ]
机构
[1] North China Elect Power Univ, Sch Elect Elect Engn, Beijing, Peoples R China
关键词
Modular Multi-level Converter (MMC); Multi-terminal direct current (MTDC); Fault ride-through (FRT); Droop control and Power oscillation damping; CONTROL STRATEGY; WIND FARMS; HVDC; CONVERTER; TRANSMISSION; MODULATION; TOPOLOGIES;
D O I
10.1109/ICEEE55327.2022.9772595
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Modular multi-level converter (MMC) has been recognized as the most prominent topology in building the multi-terminal direct current (MTDC systems) due to its numerous advantages over other converter topologies. The primary concern for the operation of such advanced MTDC grids is to ensure the reliability and safety of the electrical equipment during dynamic and transient conditions following standard grid codes. This research work proposes a combination of different control strategies developed for MMC based MTDC systems to promote fault ride-through capability during three-phase transients and voltage dips. The proposed control architecture contains inner and outer control loops for MMC stations. Along with the different control strategies, the inherent energy available in the capacitors of submodules MMC has also been utilized, which ensures constant power delivery to the load system during three-phase transients & voltage dips and provides power oscillation damping (POD) with quick post fault recovery operation. The energy dimensions required for capacitors of each MMC station are calculated. The proposed control strategies have been validated with an experimental setup of a four-terminal MMC based MTDC system developed in the simulation environment. The proposed control strategies envision a robust fault ride-through capability with reduced oscillations and total harmonic distortion (THD). Such a method is more reliable for an MTDC system than the classical solutions, which are based on drawing increased current from the grid or using additional circuitries. Moreover, the proposed control strategies can work efficiently for any MTDC system as compared to previously presented solutions, which are restricted to two-terminal HVDC systems.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [31] Fault Ride-Through Control of Cascaded H-Bridge Converter-Based Battery Energy Storage Systems with Redundant Submodules
    Liang, Gaowen
    Yadav, Gorla Naga Brahmendra
    Rodriguez, Ezequiel
    Farivar, Glen G.
    Pou, Josep
    2022 IEEE 7TH SOUTHERN POWER ELECTRONICS CONFERENCE, SPEC, 2022,
  • [32] Increase of Fault Ride-Through Capability of Wind Farms by Using Bridge-Type Fault Current Limiter
    Ahmadi, H.
    Sheisi, G. H.
    Firouzi, M.
    2012 INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES 2012), 2012, 13 : 48 - 55
  • [33] A grid-side fault ride-through method suitable for offshore wind farms connected with MMC-MTDC
    Jia K.
    Dong X.
    Li J.
    Li Y.
    Niu H.
    Bi T.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (21): : 76 - 85
  • [34] A Novel Fault Ride-Through Strategy Based on Capacitor Energy Storage Inside MMC
    Xiao, Yuntao
    Peng, Li
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (08) : 7960 - 7971
  • [35] A Practical DC Fault Ride-Through Method for MMC Based MVDC Distribution Systems
    Wang, Yizhen
    Li, Qingquan
    Li, Bin
    Wei, Tianliu
    Zhu, Zhe
    Li, Weiwei
    Wen, Weijie
    Wang, Chengshan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (04) : 2510 - 2519
  • [36] Precharging and DC Fault Ride-Through of Hybrid MMC-Based HVDC Systems
    Zeng, Rong
    Xu, Lie
    Yao, Liangzhong
    Morrow, D. John
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1298 - 1306
  • [37] Coordinated Control Strategy of Fault Ride-through for DC Grid Based on Hybrid MMC
    Li, Guoqing
    Wang, Xiaoxue
    Jiang, Shouqi
    Xin, Yechun
    Wang, Tuo
    Dianwang Jishu/Power System Technology, 2024, 48 (12): : 4817 - 4825
  • [38] Stepwise Voltage Drop and Transient Current Control Strategies to Enhance Fault Ride-Through Capability of MMC-HVDC Connected DFIG Wind Farms
    Zhu, Meng
    Li, Weixing
    Liang, Xiaodong
    Xu, Shiyun
    Zhou, Baorong
    Shen, Yan
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (03) : 2127 - 2137
  • [39] AC Fault Ride-Through Capability of a VSC-HVDC Transmission Systems
    Adam, G. P.
    Ahmed, K. H.
    Finney, S. J.
    Williams, B. W.
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 3739 - 3745
  • [40] A Hierarchical Control Strategy With Fault Ride-Through Capability for Variable Frequency Transformer
    Ambati, Bharath Babu
    Kanjiya, Parag
    Khadkikar, Vinod
    El Moursi, Mohamed Shawky
    Kirtley, James L., Jr.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (01) : 132 - 141