A novel amperometric biosensor based on ZnO:Co nanoclusters for biosensing glucose

被引:138
|
作者
Zhao, Z. W. [1 ]
Chen, X. J.
Tay, B. K.
Chen, J. S.
Han, Z. J.
Khor, Khiam Aik [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 23卷 / 01期
关键词
ZnO; nanoclusters; glucose biosensor; cross-linking;
D O I
10.1016/j.bios.2007.03.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
ZnO:Co nanoclusters were synthesized by nanocluster-bearn deposition with averaged particle size of 5 nm and porous structure, which were for the first time adopted to construct a novel amperometric glucose biosensor. Glucose oxidase was immobilized into the ZnO:Co nanocluster-assembled thin film through Nafion-assisted cross-linking technique. Due to the high specific active sites and high electrocatalytic activity of the ZnO:Co nanoclusters, the constructed glucose biosensor showed a high sensitivity of 13.3 mu A/mA cm(2). The low detection limit was estimated to be 20 mu M (S/N = 3) and the apparent Michaelis-Menten constant was found to be 21 mM, indicating the high affinity of the enzyme on ZnO:Co nanoclusters to glucose. The results show that the ZnO:Co nanocluster-assembled thin films with nanoporous structure and nanocrystallites have potential applications as platforms to immobilize enzyme in biosensors. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 50 条
  • [41] Amperometric glucose biosensor based on platinum nanoparticle encapsulated with a clay
    Xiao Han
    Yihua Zhu
    Xiaoling Yang
    Chunzhong Li
    Microchimica Acta, 2010, 171 : 233 - 239
  • [42] Amperometric glucose biosensor based on platinum nanoparticle encapsulated with a clay
    Han, Xiao
    Zhu, Yihua
    Yang, Xiaoling
    Li, Chunzhong
    MICROCHIMICA ACTA, 2010, 171 (3-4) : 233 - 239
  • [43] Disposable amperometric biosensor based on nanostructured bacteriophages for glucose detection
    Kang, Yu Ri
    Hwang, Kyung Hoon
    Kim, Ju Hwan
    Nam, Chang Hoon
    Kim, Soo Won
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (10)
  • [44] Study on the amperometric glucose biosensor based on tin oxide electrode
    Liao, Cheng-Wei
    Chou, Jung-Chuan
    Sun, Tai-Ping
    Hsiung, Shen-Kan
    Hsieh, Jui-Hsiang
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 291 - 294
  • [45] Application of a datalogger in biosensing: A glucose biosensor
    Choi, MMF
    Wong, PS
    JOURNAL OF CHEMICAL EDUCATION, 2002, 79 (08) : 982 - 984
  • [46] Development of an amperometric biosensor on a toothbrush for glucose
    Liu, Yiqun
    Yue, Wei
    Cui, Yue
    SENSORS AND ACTUATORS REPORTS, 2023, 5
  • [47] Amperometric glucose biosensor based on immobilization of glucose oxidase on a magnetic glassy carbon electrode modified with a novel magnetic nanocomposite
    Baghayeri, Mehdi
    Veisi, Hojat
    Ghanei-Motlagh, Masoud
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 249 : 321 - 330
  • [48] A novel amperometric glucose biosensor based on reconstitution of glucose oxidase on thiophene-3-boronic acid polymer layer
    Senel, Mehmet
    Dervisevic, Muamer
    Cevik, Emre
    CURRENT APPLIED PHYSICS, 2013, 13 (07) : 1199 - 1204
  • [49] Novel amperometric glucose biosensor based on covalent immobilization of glucose oxidase on poly(pyrrole propylic acid)/Au nanocomposite
    Senel, Mehmet
    Nergiz, Cevdet
    CURRENT APPLIED PHYSICS, 2012, 12 (04) : 1118 - 1124
  • [50] One-step electropolymeric co-immobilization of glucose oxidase and heparin for amperometric biosensing of glucose
    Wang, J
    Chen, L
    Hocevar, SB
    Ogorevc, B
    ANALYST, 2000, 125 (08) : 1431 - 1434