Experimental performance evaluation of a multi-diaphragm pump of a micro-ORC system

被引:20
|
作者
Carraro, Gianluca [1 ]
Pallis, Platon [2 ]
Leontaritis, Aris D. [2 ]
Karellas, Sotirios [2 ]
Vourliotis, Panagiotis [2 ]
Rech, Sergio [1 ,3 ]
Lazzaretto, Andrea [1 ]
机构
[1] Univ Padua, Dept Ind Engn, Via Venezia 1, I-35131 Padua, Italy
[2] Natl Tech Univ Athens, Lab Steam Boilers & Thermal Plants, 9 Iroon Polytech, Athens 15780, Greece
[3] Univ Padua, Interdepet Ctr Giorgio Levi Cases Energy Econ & T, Via Marzolo 9, I-35131 Padua, Italy
关键词
micro-ORC system; multi-diaphragm pump; experimental investigation;
D O I
10.1016/j.egypro.2017.09.232
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of micro-scale ORC systems strongly depends on the performance of their key components. While the heat exchangers and expander have been extensively investigated, the pump has only received limited attention. The main purpose of this work is the experimental characterization of a multi-diaphragm positive displacement pump, integrated in an experimental ORC system with a rated power output of 4kWel. The study focuses on the experimental evaluation of the pump performance and on cavitation phenomena. A detailed presentation of the experimental procedure and results is supplied. A great effort has been spent in calculating the global and volumetric pump efficiencies for a wide range of operational conditions, which reach maximum values around 45-48% and 95%, respectively. With regards to cavitation issues, the effect of the available Net Positive Suction Head at the pump inlet has been deeply investigated both at partial and full load to obtain guidelines for stable operation. Finally, an extensive dataset of steady-state operating points has been used to calibrate an improved version of a semi-empirical model previously developed for positive displacement ORC pumps. Special attention has been given to the ability of the model to accurately predict the behaviour and performance of the pump at different, properly chosen, steady-state conditions. Relative errors in between 0.5%, for the outlet temperature, and 10%, for the electric power consumption, are achieved. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1018 / 1025
页数:8
相关论文
共 50 条
  • [31] Experimental thermal performance comparison of the same ORC system operated in Harbin and Taipei
    Liu, Jian
    Zhang, Yaning
    Li, Hongye
    Zhao, Wenke
    Hung, Tzu-Chen
    Li, Bingxi
    ENERGY, 2023, 275
  • [32] Experimental investigation on the performance of a twin-screw expander used in an ORC system
    Hu, Fengfan
    Zhang, Zhen
    Chen, Wenqing
    He, Zhilong
    Wang, Xiaolin
    Xing, Ziwen
    1ST INTERNATIONAL CONFERENCE ON ENERGY AND POWER, ICEP2016, 2017, 110 : 210 - 215
  • [33] Experimental study of the thermodynamic performance of the ORC-VCC system with a zeotropic mixture
    Wang, Zhiqi
    Zhao, Yabin
    Xia, Xiaoxia
    Zhang, Sifeng
    Xiao, Yao
    Zhang, Xiaoyue
    Chen, Weisun
    APPLIED THERMAL ENGINEERING, 2024, 250
  • [34] MODELING AND EXPERIMENTAL INVESTIGATION OF AN OIL-FREE MICRO COMPRESSOR-TURBINE UNIT FOR AN ORC DRIVEN HEAT PUMP
    Demierre, Jonathan
    Rubino, Antonio
    Schiffmann, Juerg
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 3B, 2014,
  • [35] Experimental study on the performance of multi-split heat pump system with thermal energy storage
    Kim, Gwi Taek
    Choi, Young Uk
    Chung, Yoong
    Kim, Mo Se
    Park, Keon Woo
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 88 : 523 - 537
  • [36] Performance evaluation of a PVT/ORC (photovoltaic thermal/organic Rankine cycle) system with optimization of the ORC and evaluation of several PV (photovoltaic) materials
    Tourkov, Konstantin
    Schaefer, Laura
    ENERGY, 2015, 82 : 839 - 849
  • [37] EXPERIMENTAL EVALUATION OF SYSTEM PERFORMANCE
    BARD, Y
    IBM SYSTEMS JOURNAL, 1973, 12 (03) : 302 - 314
  • [38] Evaluation of the performance of a multi-propped diaphragm wall during construction
    DeMoor, EK
    Stevenson, MC
    GEOTECHNICAL ASPECTS OF UNDERGROUND CONSTRUCTION IN SOFT GROUND, 1996, : 111 - 116
  • [39] Experimental and performance analyses of a turbomolecular pump rotor system
    Hsu, Chih-Neng
    VACUUM, 2015, 121 : 260 - 273
  • [40] Experimental study on the performance of heat pump drying system
    Zhang, Xukun
    Li, Huadong
    Xu, Gang
    Xiong, Kangming
    Gu, Zhen
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2006, 22 (04): : 94 - 98