Three-dimensional observation of mouse tongue muscles using micro-computed tomography

被引:5
|
作者
Aoyagi, Hidekazu [1 ]
Iwasaki, Shin-ichi [2 ]
Nakamura, Kenzirou [1 ]
机构
[1] Nippon Dent Univ, Adv Res Ctr, Sch Life Dent Niigata, Chuo Ku, Niigata 9518580, Japan
[2] Nippon Dent Univ, Sch Life Dent Niigata, Dept Physiol, Chuo Ku, Niigata 9518580, Japan
关键词
Tongue muscles; Three-dimensional observation; Micro-CT; MORPHOLOGY; ANATOMY; RAT; CT; ORGANIZATION; ARCHITECTURE; PROTRUSION; APPARATUS; MRI;
D O I
10.1007/s10266-013-0131-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study is to obtain information about the mouse tongue muscle rendered using micro-computed tomography (mu CT) at low, middle, and high magnifications. Three-dimensional (3D) mu CT is used in various fields. Most mu CT observations are restricted to hard tissue in biomaterial samples. Recently, with the use of osmium tetroxide, mu CT has been effectively employed to observe soft tissue; it is now believed that mu CT observation of soft tissue is feasible. On the other hand, the structure of the tongue muscle has been well studied, but cross-sectional imaging enhanced by 3D rendering is lacking. We chose the mouse tongue as a soft tissue case study for mu CT and generated cross-sectional images of the tongue enhanced by 3-D image rendering with histological resolution. During this observation, we developed new methods of low-magnification observation to show the relation between the tongue muscles and surrounding tissues. We also applied high-resolution mu CT in high-magnification observation of muscle fiber fascicles. Our methodological techniques give the following results: (1) For low-magnification observation (field of view: 12,000 mu m), pretreatment with decalcification and freeze drying is suitable for observing the area between the muscle of the tongue and the bone around the tongue using mu CT. (2) For middle-magnification observation (Field of view: 3,500 mu m), the use of osmium tetroxide to observe the muscle arrangement of the tongue by mu CT is suitable. (3) For high-magnification observation (Field of view: 450 mu m), high-resolution mu CT is suitable for observation of the transversus muscle fiber fascicles.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] Three-dimensional structure of the orbicularis retaining ligament: an anatomical study using micro-computed tomography
    Jehoon, O.
    Kwon, Hyun-Jin
    Choi, You-Jin
    Cho, Tae-Hyeon
    Yang, Hun-Mu
    SCIENTIFIC REPORTS, 2018, 8
  • [22] Three-dimensional structure of the orbicularis retaining ligament: an anatomical study using micro-computed tomography
    Jehoon O
    Hyun-Jin Kwon
    You-Jin Choi
    Tae-Hyeon Cho
    Hun-Mu Yang
    Scientific Reports, 8
  • [23] Three-Dimensional Imaging of Hepatic Sinusoids in Mice Using Synchrotron Radiation Micro-Computed Tomography
    Yoon, Yae Jin
    Chang, Soeun
    Kim, Oh Youn
    Kang, Bo-Kyeong
    Park, Jaesung
    Lim, Jae-Hong
    Huang, Jung Yun
    Kim, Yoon-Keun
    Byun, Jae Ho
    Gho, Yong Song
    PLOS ONE, 2013, 8 (07):
  • [24] Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography
    Folarin, A. A.
    Konerding, M. A.
    Timonen, J.
    Nagl, S.
    Pedley, R. B.
    MICROVASCULAR RESEARCH, 2010, 80 (01) : 89 - 98
  • [25] A new method for the quantification of aortic calcification by three-dimensional micro-computed tomography
    Huesa, C.
    Millan, J. L.
    van 't Hof, R. J.
    MacRae, V. E.
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2013, 32 (05) : 1047 - 1050
  • [26] Evaluation of three-dimensional image registration methodologies for in vivo micro-computed tomography
    Boyd, Steven K.
    Moser, Stephan
    Kuhn, Michael
    Klinck, Robert J.
    Krauze, Peter L.
    Mueller, Ralph
    Gasser, Juerg S.
    ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (10) : 1587 - 1599
  • [27] Three-dimensional characterization of metal foam structures via micro-computed tomography
    Illerhaus, B
    Goebbels, J
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2000, 31 (06) : 527 - 528
  • [28] Evaluation of Three-dimensional Image Registration Methodologies for In Vivo Micro-computed Tomography
    Steven K. Boyd
    Stephan Moser
    Michael Kuhn
    Robert J. Klinck
    Peter L. Krauze
    Ralph Müller
    Jürg A. Gasser
    Annals of Biomedical Engineering, 2006, 34 : 1587 - 1599
  • [29] Morphological evaluation of cranial and maxillary shape differences of the brachymorphic mouse with spontaneous malocclusion using three-dimensional micro-computed tomography
    Saito, F.
    Kajii, T. S.
    Sugawara-Kato, Y.
    Tsukamoto, Y.
    Arai, Y.
    Hirabayashi, Y.
    Fujimori, O.
    Iida, J.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2011, 14 (02) : 100 - 106
  • [30] Anatomical Characterization and Three-Dimensional Modeling of the Muscles at the Corner of the Mouth: An Iodine Staining Technique Based on Micro-Computed Tomography
    Sun, Min
    Chen, Guo C.
    Wang, Yong Q.
    Song, Tao
    Li, Hai D.
    Wu, Di
    Yin, Ning B.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2018, 142 (03) : 782 - 785