摘要
Purpose: The purpose of this study was to evaluate the diagnostic performance of ultra-short echo time magnetic resonance imaging (UTE MRI) in the assessment of pulmonary arteriovenous malformation (PAVM). Methods: Eighteen consecutive patients (mean [+/- standard deviation] age, 48.6 +/- 16.8 years) with 46 untreated PAVMs who underwent and thin-section computed tomography (CT) and UTE MRI with a 1.5-Tesla and 3-Tesla unit were retrospectively assessed. Two radiologists evaluated the diagnostic capabilities of UTE MRI for the detection and classification of PAVMs with reference to CT. Sensitivity, specificity, and kappa statistics were calculated with reference to CT. We also compared the differences in PAVM measurements between CT and MRI. Results: The sensitivity and specificity of UTE-MRI for the detection of PAVMs were 89.1% and 100%, respectively, for reader 1 and 87.0% and 100%, respectively, for reader 2. In the classification of PAVMs, inter-modality agreement in reader 1 and 2 were both substantial (kappa = 0.78 and 0.69, respectively). The measurements of the PAVM feeding artery and sac on CT and MRI were strongly correlated in both readers 1 and 2 (R2 = 0.981 and 0.983, respectively). Both readers 1 and 2 slightly underestimated the diameter of the PAVM feeding artery and sac on UTE MRI (p < 0.001). Conclusion: This study indicates that UTE MRI is a feasible and promising modality for noninvasive assessment of PAVMs.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Sodium magnetic resonance imaging using ultra-short echo time sequences with anisotropic resolution and uniform k-space sampling
    Konstandin, Simon
    Kraemer, Philipp
    Guenther, Matthias
    Schad, Lothar R.
    MAGNETIC RESONANCE IMAGING, 2015, 33 (03) : 319 - 327
  • [22] Use of Ultra-Short Echo Time MRI to Improve Temporal Bone Imaging
    Kaufman, A. C.
    Fu, F.
    Martinez, M. C.
    Fischbein, N.
    Popelka, G. R.
    Pauly, K. Butts
    Blevins, N. H.
    LARYNGOSCOPE, 2024, 134 (11): : 4691 - 4696
  • [23] Characterization of the ultra-short echo time magnetic resonance (UTE MR) collagen signal associated with myocardial fibrosis
    Adrienne G Siu
    Andrew Ramadeen
    Xudong Hu
    Lily Morikawa
    Li Zhang
    Justin Lau
    Garry Liu
    Mihaela Pop
    Kim A Connelly
    Paul Dorian
    Graham A Wright
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [24] Segmentation and visualization of the human cranial bone by T2*approximation using ultra-short echo time (UTE) magnetic resonance imaging
    Kraemer, Martin
    Herzau, Benedikt
    Reichenbach, Juergen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (01): : 51 - 59
  • [25] A Modified EPI Sequence for High-Resolution Imaging at Ultra-Short Echo Time
    Hetzer, Stefan
    Mildner, Toralf
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 165 - 175
  • [26] Signal decay correction in 2D ultra-short echo time imaging
    Mentrup, D
    Eggers, H
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (02) : 62 - 70
  • [27] Signal Decay Correction in 2D Ultra-Short Echo Time Imaging
    Detlef Mentrup
    Holger Eggers
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 62 - 70
  • [28] Pulmonary Structural MRI using Free-Breathing, Self-Gated Ultra-short Echo Time Imaging
    Niedbalski, Peter J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (211):
  • [29] SHORT ECHO TIME MAGNETIC-RESONANCE-IMAGING OF TENDON
    KOBLIK, PD
    FREEMAN, DM
    INVESTIGATIVE RADIOLOGY, 1993, 28 (12) : 1095 - 1100
  • [30] Ventilation/Perfusion Imaging of the Lung Using Ultra-short Echo Time (UTE) MRI in an Animal Model of Pulmonary Embolism
    Togao, Osamu
    Ohno, Yoshiharu
    Dimitrov, Ivan
    Hsia, Connie C.
    Takahashi, Masaya
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 539 - 546