A novel method for counting eimerian oocysts at very low concentrations in aqueous suspensions

被引:2
|
作者
Williams, RB
Marshall, JA
Catchpole, J
机构
[1] Schering Plough Anim Hlth, Uxbridge UB9 6LS, Middx, England
[2] Vet Labs Agcy, Weybridge KT15 3NB, Surrey, England
关键词
D O I
10.1053/rvsc.2001.0489
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A novel method for counting eimerian oocysts in samples of drinking water has been developed to fulfil the need for monitoring the delivery of very low concentrations of live anticoccidial vaccines to poultry via pipeline nipple-drinker systems. Advantages of the method are the case of sample collection and processing, high degrees of accuracy and precision, and a sensitivity of one oocyst in ml(-1). Results of a validation test are presented, with a protocol for the method and notes on its use. The coefficient of variation (CoV) of 10 sets of oocyst counts with nominal means of 10 to 160 oocysts ml(-1) ranged from about 16 per cent down to 6 per cent. The recovery efficiency for all 100 validation counts averaged 100.2 per cent with a range of 70-130 per cent. A practical example of field use of the method is given, including a modification to decrease the time taken for counting. In this case, when oocysts were pumped around a pipeline circuit of 129 m for 2.5 hours, the CoV of a mean of 112 oocysts ml(-1) (n = 10) was 12.4 per cent. (C) 2001 Harcourt Publishers Ltd.
引用
收藏
页码:67 / 71
页数:5
相关论文
共 50 条
  • [21] AN ENHANCED FLOW CYTOMETRIC METHOD FOR COUNTING VERY-LOW NUMBERS OF WBCS IN PLATELET PRODUCTS
    DUMONT, LJ
    DUMONT, DF
    TRANSFUSION, 1995, 35 (10) : S218 - S218
  • [22] A modified flow cytometric method for counting very low numbers of white cells in platelet concentrates
    Tanaka, M
    Seno, T
    Shibata, H
    Kobayashi, Y
    Okubo, Y
    TRANSFUSION, 1997, 37 (01) : 102 - 103
  • [23] Enhanced flow cytometric method for counting very low numbers of white cells in platelet products
    Dumont, LJ
    Dumont, DF
    CYTOMETRY, 1996, 26 (04): : 311 - 316
  • [24] A Novel Method for Measuring the Sizes and Concentrations of 5-500 nm Particles in Colloidal Suspensions
    Van Schooneveld, H. Gary
    Litchy, Mark R.
    Grant, Donald C.
    NANOTECHNOLOGY 2011: ADVANCED MATERIALS, CNTS, PARTICLES, FILMS AND COMPOSITES, NSTI-NANOTECH 2011, VOL 1, 2011, : 41 - 44
  • [25] A rapid colorimetric method for the determination of lead (II) at low concentrations in aqueous solution
    Netzahual-Lopantzi, A.
    Juarez-Santacruz, L.
    Garcia-Nieto, E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2023, 20 (12) : 13191 - 13198
  • [26] A rapid colorimetric method for the determination of lead (II) at low concentrations in aqueous solution
    A. Netzahual-Lopantzi
    L. Juárez-Santacruz
    E. García-Nieto
    International Journal of Environmental Science and Technology, 2023, 20 : 13191 - 13198
  • [27] A DIRECT AMPEROMETRIC METHOD FOR CONTINUOUS DETERMINATION OF LOW CONCENTRATIONS OF IODINE IN AQUEOUS SOLUTIONS
    BARTON, AFM
    WRIGHT, GA
    ANALYTICA CHIMICA ACTA, 1968, 43 (02) : 328 - &
  • [28] Development of a novel method to determine very low density lipoprotein kinetics
    Al-Shayji, Iqbal A. R.
    Gill, Jason M. R.
    Cooney, Josephine
    Siddiqui, Samira
    Caslake, Muriel J.
    JOURNAL OF LIPID RESEARCH, 2007, 48 (09) : 2086 - 2095
  • [29] A novel method to prepare wafers with very low COPs for bonded SOI
    Vasat, JL
    Torack, T
    SOLID STATE TECHNOLOGY, 2003, 46 (03) : 63 - +
  • [30] Nageotte chamber method for very low number of leukocytes counting validated for srored red blood cells
    Fomovskaia, GN
    Haddock, TF
    Kubish, GN
    Penezina, OP
    Davenport, RD
    TRANSFUSION, 1999, 39 (10) : 17S - 17S