Sensitive Determination of Acyclovir in Biological and Pharmaceutical Samples Based on Polymeric Film Decorated with Nanomaterials on Nanoporous Glassy Carbon Electrode

被引:17
|
作者
Hamtak, Maryam [1 ]
Fotouhi, Lida [1 ]
Hosseini, Morteza [2 ]
Dorraji, Parisa Seyed [1 ]
机构
[1] Alzahra Univ, Fac Phys & Chem, Dept Chem, Tehran, Iran
[2] Univ Tehran, Fac New Sci & Technol, Dept Life Sci Engn, Tehran, Iran
基金
美国国家科学基金会;
关键词
ANTIVIRAL DRUG ACYCLOVIR; VOLTAMMETRIC DETERMINATION; PHARMACOKINETIC PROPERTIES; ELECTROCHEMICAL OXIDATION; SILVER NANOPARTICLES; GRAPHENE; NANOTUBES; IMMOBILIZATION; NANOCOMPOSITE; BEHAVIORS;
D O I
10.1149/2.1051813jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In the present study, a new sensor was designed by casting of multi-walled carbon nanotubes (MWCNTs) and TiO2 nanoparticles (TiO2 NPs) into the polymeric matrix, which polymerized in the nanoporous glassy carbon electrode. The morphological characterization of the new electrode was examined by field emission scanning electron microscopy. The performance of the electrode was demonstrated by applying it to the analytical determination of acyclovir concentration by differential pulse anodic stripping voltammetry. The oxidation of acyclovir has a better result on the modified electrode because of the synergistic effect of nanoporous structure glassy carbon electrode and polymeric film and MWCNTs+TiO2 NPs. The measurement of acyclovir on the fabricated electrode has the best response under the conditions of 0.10 mol cm(-3) phosphate buffer solution (pH 7.0), accumulation potential of 0.6 V, and accumulation time of 180 s. Under the optimized conditions, the response of this electrode to the concentration of acyclovir was a single linear range ranges from 0.03 to 1.0 mu mol dm(-3) with a detection limit of 0.01 mu mol dm(-3). Selective detection of acyclovir in the presences of ascorbic acid, dopamine and guanine, could be possible. The measurement of acyclovir concentrations in human fluid and tablet samples demonstrated electrode applicability. (C) 2018 The Electrochemical Society.
引用
收藏
页码:B632 / B637
页数:6
相关论文
共 50 条
  • [31] Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode
    Muralidharan, B.
    Gopu, G.
    Vedhi, C.
    Manisankar, P.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (08) : 1177 - 1184
  • [32] Sensitive and selective determination of hydrazine using glassy carbon electrode modified with Pd nanoparticles decorated multiwalled carbon nanotubes
    Behzad Haghighi
    Hassan Hamidi
    Somayyeh Bozorgzadeh
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1411 - 1416
  • [33] Sensitive and selective determination of hydrazine using glassy carbon electrode modified with Pd nanoparticles decorated multiwalled carbon nanotubes
    Haghighi, Behzad
    Hamidi, Hassan
    Bozorgzadeh, Somayyeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (03) : 1411 - 1416
  • [34] Rod-like CuO nanoparticles/waste masks carbon modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-cancer drug pazopanib in biological and pharmaceutical samples
    Bilge, Selva
    Dogan-Topal, Burcu
    Atici, Esen Bellur
    Sinag, Ali
    Ozkan, Sibel A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
  • [35] A selective and sensitive electrochemical determination of catechol based on reduced graphene oxide decorated β-cyclodextrin nanosheet modified glassy carbon electrode
    Nikhil, S.
    Karthika, A.
    Suresh, P.
    Suganthi, A.
    Rajarajan, M.
    ADVANCED POWDER TECHNOLOGY, 2021, 32 (07) : 2148 - 2159
  • [36] Carbon Nanomaterials Based Electrochemical Sensors/Biosensors for the Sensitive Detection of Pharmaceutical and Biological Compounds
    Adhikari, Bal-Ram
    Govindhan, Maduraiveeran
    Chen, Aicheng
    SENSORS, 2015, 15 (09) : 22490 - 22508
  • [37] Electrochemical determination of endosulfan in vegetable samples using mercury film modified glassy carbon electrode
    Tefera, Molla
    Tessema, Merid
    Admassie, Shimelis
    Guadie, Atnafu
    SENSING AND BIO-SENSING RESEARCH, 2021, 33
  • [38] Sensitive voltammetric determination of riboflavin in pharmaceutical and biological samples using FSN-Zonyl-Nafion modified carbon paste electrode
    Stefanov, Cristina
    Negut, Catalina Cioates
    Gugoasa, Livia Alexandra Dinu
    van Staden, Jacobus Frederick
    MICROCHEMICAL JOURNAL, 2020, 155
  • [39] Determination of ornidazole in pharmaceutical dosage forms based on reduction at an activated glassy carbon electrode
    Ozkan, SA
    Senturk, Z
    Biryol, I
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1997, 157 (02) : 137 - 144
  • [40] Sensitive determination of domperidone in biological fluids using a conductive polymer modified glassy carbon electrode
    Gupta, Pankaj
    Goyal, Rajendra N.