Determination of 99Tc in fresh water using TRU resin by ICP-MS

被引:16
|
作者
Guerin, Nicolas [1 ]
Riopel, Remi [1 ]
Kramer-Tremblay, Sheila [1 ]
de Silva, Nimal [1 ]
Cornett, Jack [1 ]
Dai, Xiongxin [1 ]
机构
[1] CNL, Radiol Protect Res & Instrumentat Branch, Chalk River, ON K0J 1J0, Canada
关键词
Technetium-99; Rhenium; Inductively coupled plasma mass spectrometry; TRU resin; Anion exchange resin; Environmental water samples; ENVIRONMENTAL-SAMPLES; VAPOR-PRESSURES; TECHNETIUM; RHENIUM; SEPARATION; EXTRACTION; HEPTOXIDE; LOBSTERS; TC;
D O I
10.1016/j.aca.2017.08.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Technetium-99 (Tc-99) determination at trace level by inductively coupled plasma mass spectrometry (ICP-MS) is challenging because there is no readily available appropriate Tc isotopic tracer. A new method using Re as a recovery tracer to determine Tc-99 in fresh water samples, which does not require any evaporation step, was developed. Tc(VII) and Re(VII) were pre-concentrated on a small anion exchange resin (AER) cartridge from one litre of water sample. They were then efficiently eluted from the AER using a potassium permanganate (KMnO4) solution. After the reduction of KMnO4 in 2 M sulfuric acid solution, the sample was passed through a small TRU resin cartridge. Tc(VII) and Re(VII) retained on the TRU resin were eluted using near boiling water, which can be directly used for the ICP-MS measurement. The results for method optimisation, validation and application were reported. Crown Copyright (C) 2017 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [1] 99Tc detection in water samples by ICP-MS
    Mas, JL
    García-León, M
    Bolívar, JP
    RADIOCHIMICA ACTA, 2004, 92 (01) : 39 - 46
  • [2] Determination of 99Tc in environmental samples and depleted uranium penetrators using ICP-MS
    Hans Sahli
    Stefan Röllin
    José A. Corcho Alvarado
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 311 : 1633 - 1642
  • [3] Determination of 99Tc in environmental samples and depleted uranium penetrators using ICP-MS
    Sahli, Hans
    Rollin, Stefan
    Alvarado, Jose A. Corcho
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 311 (03) : 1633 - 1642
  • [4] Development of a novel method for the determination of 99Tc in environmental samples by ICP-MS
    McCartney, M
    Rajendran, K
    Olive, V
    Busby, RG
    McDonald, P
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) : 1849 - 1852
  • [5] Comparison of a radiation counting method and ICP-MS for the determination of 99Tc in environmental samples
    Tagami, K
    Uchida, S
    Garcia-Leon, M
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 147 - 151
  • [6] ICP-MS法测定食品中微量99Tc
    熊超杰
    白雪
    赵立飞
    谈树苹
    常志远
    分析试验室, 2018, 37 (09) : 1025 - 1028
  • [8] 99Tc bioassay: a direct comparison of liquid scintillation radiation detection and ICP-MS mass detection of the 99Tc isotope
    Lewis, Linda A.
    Schweitzer, George K.
    ASTM Special Technical Publication, 1999, (1344): : 99 - 110
  • [9] ICP-MS测定低放废水中的99Tc
    崔安智
    李金英
    刘峻岭
    李大明
    郭景儒
    刘春秀
    孙宏清
    杜洪铭
    原子能科学技术, 2001, (03) : 211 - 216
  • [10] Comparison of two ICP-MS set-ups for measuring 99Tc in large volume water samples
    Keith-Roach, MJ
    Stürup, S
    Oughton, DH
    Dahlgaard, H
    ANALYST, 2002, 127 (01) : 70 - 75