Spin-echo and diffusion-weighted MRI in differentiation between progressive massive fibrosis and lung cancer

被引:8
|
作者
Guneyli, Serkan [1 ]
Tor, Meltem [2 ]
Hassoy, Hur [3 ]
Aygun, Murat Serhat [1 ]
Altinmakas, Emre [1 ]
Altintas, Susamber Dik [2 ]
Savas, Recep [4 ]
机构
[1] Koc Univ, Dept Radiol, Istanbul, Turkey
[2] Bulent Ecevit Univ, Dept Pulmonol, Zonguldak, Turkey
[3] Ege Univ, Dept Publ Hlth, Izmir, Turkey
[4] Ege Univ, Dept Radiol, Izmir, Turkey
关键词
COAL-WORKERS PNEUMOCONIOSIS; SOLITARY; PET; CT;
D O I
10.5152/dir.2021.20344
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to investigate the value of magnetic resonance imaging (MRI)- based parameters in differentiating between progressive massive fibrosis (PMF) and lung cancer. METHODS This retrospective study included 60 male patients (mean age, 67.0 +/- 9.0 years) with a history of more than 10 years working in underground coal mines who underwent 1.5 T MRI of thorax due to a lung nodule/mass suspicious for lung cancer on computed tomography. Thirty patients had PMF, and the remaining ones had lung cancer diagnosed histopathologically. The sequences were as follows: coronal single-shot turbo spin echo (SSH-TSE), axial T1- and T2-weighted spin-echo (SE), balanced turbo field echo, T1-weighted high- resolution isotropic volume excitation, free-breathing and respiratory triggered diffusion-weighted imaging (DWI). The patients' demographics, lesion sizes, and MRI-derived parameters were compared between the patients with PMF and lung cancer. RESULTS Apparent diffusion coefficient (ADC) values of DWI and respiratory triggered DWI, signal intensities on T1-weighted SE, T2-weighted SE, and SSH-TSE imaging were found to be significantly different between the groups (p < 0.001, for all comparisons). Median ADC values of free-breathing DWI in patients with PMF and cancer were 1.25 (0.93-2.60) and 0.76 (0.53-1.00) (x 10(-3) mm(2)/s), respectively. Most PMF lesions were predominantly iso- or hypointense on T1- weighted SE, T2-weighted SE, and SSH-TSE, while most malignant ones predominantly showed high signal intensity on these sequences. CONCLUSION MRI study including SE imaging, specially T1-weighted SE imaging and ADC values of DWI can help to distinguish PMF from lung cancer.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [21] High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition of data with fast spin-echo) MRI
    Department of Radiology, University of Arizona, Tucson, AZ, United States
    不详
    不详
    Magn. Reson. Med., 1 (11-18):
  • [22] High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition of data with fast spin-echo) MRI
    Trouard, TP
    Theilmann, RJ
    Altbach, MI
    Gmitro, AF
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 11 - 18
  • [23] Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo MRI (vol 56, pg 1283, 2006)
    Jin, Tao
    Zhao, Fuqiang
    Kim, Seong-Gi
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 228 - 228
  • [25] Differentiation between hepatic hemangioma and metastases on diffusion-weighted MRI
    Sivrioglu, Ali Kemal
    Kafadar, Cahit
    CLINICAL IMAGING, 2016, 40 (01) : 183 - 183
  • [26] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [27] Diffusion-weighted MRI for differentiation between sialadenitis and pleomorphic adenoma
    Terra, Guilherme T. C.
    Oliveira, Jefferson X. D.
    Hernandez, Adalsa
    Lourenco, Silvia V.
    Arita, Emiko S.
    Cortes, Arthur R. G.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 46 (01)
  • [28] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Ryoji Mikayama
    Hidetake Yabuuchi
    Shinjiro Sonoda
    Koji Kobayashi
    Kazuya Nagatomo
    Mitsuhiro Kimura
    Satoshi Kawanami
    Takeshi Kamitani
    Seiji Kumazawa
    Hiroshi Honda
    European Radiology, 2018, 28 : 316 - 324
  • [29] Differences in apparent diffusion coefficients between normal brain echo-planar images and turbo spin-echo diffusion-weighted images with distortion correction
    Takatsu, Yasuo
    Nakamura, Masafumi
    Sagawa, Hajime
    Suzuki, Yuichi
    Mori, Nobuyuki
    Motegi, Shunichi
    Miyati, Tosiaki
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [30] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Mikayama, Ryoji
    Yabuuchi, Hidetake
    Sonoda, Shinjiro
    Kobayashi, Koji
    Nagatomo, Kazuya
    Kimura, Mitsuhiro
    Kawanami, Satoshi
    Kamitani, Takeshi
    Kumazawa, Seiji
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 316 - 324