Estimation of kinetic parameters in graphical analysis of PET imaging data

被引:80
|
作者
Ogden, RT
机构
[1] Columbia Univ, NYSPI, Dept Biostat, New York, NY 10032 USA
[2] New York State Psychiat Inst & Hosp, Dept Neurosci, New York, NY 10032 USA
关键词
brain imaging; likelihood estimation; Logan plot;
D O I
10.1002/sim.1562
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Positron emission tomography (PET) imaging is a useful tool for quantifying various aspects of the distribution of neuroreceptors throughout the human brain in vivo. A typical analysis consists of applying a pharmacokinetic model to the data, estimating the parameters of the model using non-linear least squares methods, then taking the appropriate function of estimated model parameters as a final estimate of the parameter(s) of interest. As an alternative for fitting these models, it has been shown previously that taking a particular transformation of the data results in two variables that have a linear relationship, and that the slope of this linear relationship is the parameter of primary interest. However, estimating the slope using ordinary least squares (OLS) regression results in a large negative bias. By rearranging the terms in the relationship, the problem may be reformed to allow direct application of standard estimation principles. Estimators resulting from this approach are shown via simulation to have better estimation properties as compared to the OLS estimators. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:3557 / 3568
页数:12
相关论文
共 50 条
  • [21] Estimation of kinetic parameters from projections using spectral analysis in rat-PET studies.
    Bentourkia, M
    Lapointe, D
    Selivanov, V
    Lecomte, R
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 58P - 58P
  • [22] Kinetic modeling and parameter estimation of TSPO PET imaging in the human brain
    Wimberley, Catriona
    Lavisse, Sonia
    Hillmer, Ansel
    Hinz, Rainer
    Turkheimer, Federico
    Zanotti-Fregonara, Paolo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 49 (01) : 246 - 256
  • [23] Kinetic modeling and parameter estimation of TSPO PET imaging in the human brain
    Catriona Wimberley
    Sonia Lavisse
    Ansel Hillmer
    Rainer Hinz
    Federico Turkheimer
    Paolo Zanotti-Fregonara
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 49 : 246 - 256
  • [24] Fast and robust estimation of kinetic parameters in dynamic PET imaging using neural network-based discretization method
    Shao, Wenrui
    Chen, Yixin
    Li, Nan
    Yang, Zhi
    Meng, Xiangxi
    Xie, Zhaoheng
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [25] GRAPHICAL EVALUATION OF KINETIC PARAMETERS FOR BACTERIAL GROWTH
    STRATTON, FE
    MCCARTY, PL
    CANADIAN JOURNAL OF MICROBIOLOGY, 1969, 15 (10) : 1201 - &
  • [26] Kinetic Parameter Estimations Using A Novel Probabilistic Graphical Model Given Dynamic PET Data
    Yang, Yalei
    Meng, Xiangxi
    Tian, Zifeng
    Xie, Zhaoheng
    Yang, Zhi
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [27] GRAPHICAL ESTIMATION OF MIXED WEIBULL PARAMETERS FOR UNGROUPED MULTICENSORED DATA - ITS APPLICATION TO FAILURE DATA
    NATESAN, J
    JARDINE, AKS
    MAINTENANCE MANAGEMENT INTERNATIONAL, 1986, 6 (02): : 115 - 127
  • [28] Reconstruction of linear kinetic parameters directly from projection PET data
    Angelis, G. I.
    Tziortzi, A. C.
    Tsoumpas, C.
    INTERNATIONAL CONFERENCE ON IMAGE OPTIMISATION IN NUCLEAR MEDICINE (OPTINM), 2011, 317
  • [29] Estimation of receptor concentration by kinetic modeling of dynamic PET data.
    Westera, G
    Burger, C
    Buck, A
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 643 - 643