Clinical measurement of sit-to-stand performance in people with balance disorders: Validity of data for the five-times-sit-to-stand test

被引:556
|
作者
Whitney, SL
Wrisley, DM
Marchetti, GF
Gee, MA
Redfern, MS
Furman, JM
机构
[1] Univ Pittsburgh, Dept Phys Therapy, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Dept Otolaryngol, Pittsburgh, PA 15260 USA
[3] Univ Pittsburgh, Med Ctr, Ctr Rehab Serv, Phys Therapy Dept, Pittsburgh, PA 15260 USA
[4] SUNY Buffalo, Sch Publ Hlth & Hlth Profess, Dept Rehabil Sci, Buffalo, NY 14260 USA
[5] Duquesne Univ, Rangos Sch Hlth Profess, Dept Phys Therapy, Pittsburgh, PA 15219 USA
[6] Duke Univ, Sch Med, Durham, NC 27710 USA
[7] Univ Pittsburgh, Dept Bioengn Otolaryngol & Phys Therapy, Pittsburgh, PA 15260 USA
来源
PHYSICAL THERAPY | 2005年 / 85卷 / 10期
关键词
balance; measurement; sit-to-stand test; validity;
D O I
10.1093/ptj/85.10.1034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. People with balance disorders are characterized as having difficulty with transitional movements, such as the sit-to-stand movement. A valid and feasible tool is needed to help clinicians quantify the ability of people with balance disorders to perform transitional movements. The purpose of this study was to describe the concurrent and discriminative validity of data obtained with the Five-Times-Sit-to-Stand Test (FTSST). The FTSST was compared with the Activities-specific Balance Confidence Scale (ABC) and the Dynamic Gait Index (DGI). Subjects and Methods. Eighty-one subjects without balance disorders and 93 subjects with balance disorders were recruited for the study. Each subject was asked to stand from a 43-cm-high chair 5 times as quickly as possible. The ABC and DGI scores were recorded. Results. Subjects with balance disorders performed the FTSST more slowly than subjects without balance disorders. Discriminant analysis demonstrated that the FTSST correctly identified 65% of subjects with balance dysfunction, the ABC identified 80%, and the DGI identified 78%. The ability of the FTSST to identify subjects with balance dysfunction was better for subjects younger than 60 years of age (81%). Discussion and Conclusion. The FTSST displays discriminative and concurrent validity properties that make this test potentially useful in clinical decision making, although overall the ABC and the DGI arc better than the FTSST at discriminating between subjects with and subjects without balance disorders.
引用
收藏
页码:1034 / 1045
页数:12
相关论文
共 50 条
  • [41] Correction: The five times sit-to-stand test: safety, validity and reliability with critical care survivors’s at ICU discharge
    Thiago Araújo de Melo
    Fernando Silva Guimarães
    José Roberto Lapa e Silva
    Archives of Physiotherapy, 13
  • [42] FIVE-REPETITION SIT-TO-STAND TEST: RELIABILITY, VALIDITY AND RESPONSE TO PULMONARY REHABILITATION IN COPD
    Jones, S. E.
    Kon, S. S. C.
    Canavan, J. L.
    Clark, A. L.
    Patel, M. S.
    Dilaver, D.
    Peasey, M.
    Ng, M. G. S.
    Polkey, M. I.
    Man, W. D-C
    THORAX, 2012, 67 : A53 - A53
  • [43] Velocity of the Five Sit-to-Stand Test in Older Adults: A Systematic Review
    Jerez-Mayorga, Daniel
    Miranda-Fuentes, Claudia
    Perez-Doncel, Julieta
    Rool- Maureira, Barbara
    Saavedra-Rincon, Francisca
    Zambra-Alvarez, Rocio
    Intelangelo, Leonardo
    Guede-Roja, Francisco
    RETOS-NUEVAS TENDENCIAS EN EDUCACION FISICA DEPORTE Y RECREACION, 2022, (45): : 714 - 722
  • [44] The validation of the sit-to-stand test for COPD patients
    Chambellan, Arnaud
    Nusinovici, Simon
    Vaidya, Trija
    Gourraud, Pierre-Antoine
    de Bisschop, Claire
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50 (03)
  • [45] Responsiveness and Minimal Clinically Important Difference of the Five Times Sit-to-Stand Test in Patients with Stroke
    Agustin, Rodrigo Martin-San
    Crisostomo, Ma Jose
    Sanchez-Martinez, Ma Piedad
    Medina-Mirapeix, Francesc
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (05) : 1 - 12
  • [46] Five-Repetition Sit-to-Stand Test in Idiopathic Pulmonary Fibrosis
    Jones, S. E.
    Nolan, C. M.
    Patel, S.
    Barker, R. E.
    Kwan, H.
    Maddocks, M.
    Maher, T. M.
    Cullinan, P.
    Man, W. D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [47] Measurement of Sit-to-Stand Among Older Adults
    Bohannon, Richard W.
    TOPICS IN GERIATRIC REHABILITATION, 2012, 28 (01) : 11 - 16
  • [48] Validity of accelerometry in assessing the duration of the sit-to-stand movement
    Janssen, Wim G. M.
    Bussmann, Johannes B. J.
    Horemans, Herwin L. D.
    Stam, Henk J.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (09) : 879 - 887
  • [49] Performance on Five Times Sit-to-Stand Task as a Predictor of Subsequent Falls and Disability in Older Persons
    Zhang, Fang
    Ferrucci, Luigi
    Culham, Elsie
    Metter, E. Jeffrey
    Guralnik, Jack
    Deshpande, Nandini
    JOURNAL OF AGING AND HEALTH, 2013, 25 (03) : 478 - 492
  • [50] Validity of accelerometry in assessing the duration of the sit-to-stand movement
    Wim G. M. Janssen
    Johannes B. J. Bussmann
    Herwin L. D. Horemans
    Henk J. Stam
    Medical & Biological Engineering & Computing, 2008, 46 : 879 - 887