As part of the U.S.-Japan Cooperative Research Program on Composite/Hybrid Structures (1992), investigations were carried out at the University of Nebraska-Lincoln and University of Illinois, to develop moment connection details and accompanying design provisions for connecting steel beams to circular concrete filled tube (CFT) columns. This paper provides an overview of the work carried out. Work at the University of Illinois consisted of evaluating the inelastic response of six possible connection details. Six large-scale connections were tested to failure using the quasi-static test method. Connections welded to the skin of the tube created large distortions of the tube wall, and were susceptible to weld, flange, or tube wall fracture. External diaphragm and continuous web details exhibited more favorable inelastic behavior, but the flexural strength of these connections began to deteriorate relatively early in the imposed deformation history. Continuing the flanges through the composite column showed adequate strength, however due to excessive slipping this connection did not dissipate significant inelastic dynamic energy. One of the details tested at the University of Illinois was passing the girder section through the CFT columns. This through beam detail provided the most effective detail to achieve the ideal rigid connection condition. Work at the University of Nebraska-Lincoln concentrated on comprehending the behavior of the through beam connection detail. The behavior of CFT columns under seismic loads was studied through testing six columns which were subjected to a constant axial load in addition to a cyclic lateral load. Failure modes for through beam connection detail were identified through testing seven, two-thirds scale connection specimens. These tests were used to comprehend the force transfer mechanisms between steel beams and CFT columns and develop design provisions that could estimate the capacity of the various elements of the through beam connection detail.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 50 条
  • [21] Concrete-Filled Steel Tube Columns Encased with Thin Precast Concrete
    Park, Hong-Gun
    Lee, Ho-Jun
    Choi, In-Rak
    Kim, Sung-Bae
    Park, Sung-Soon
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (12)
  • [22] Cyclic Behavior of Concrete-Filled Tube Columns with Bidirectional Moment Connections Considering the Local Slenderness Effect
    Mata, Ramon
    Nunez, Eduardo
    BUILDINGS, 2024, 14 (07)
  • [23] Stress paths of confined concrete in axially loaded circular concrete-filled steel tube stub columns
    Lin, Siqi
    Zhao, Yan-Gang
    He, Liusheng
    ENGINEERING STRUCTURES, 2018, 173 : 1019 - 1028
  • [24] Concrete-filled steel columns
    Kodur, V.K.R.
    Canadian Consulting Engineer, 1998, 39 (Special Issu):
  • [25] Axial Strength of Concrete-Filled Square Steel Tubular Columns Reinforced by Inner Circular Steel Tube
    Li, Xinzhong
    Wei, Xueying
    Zhao, Junhai
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4542 - 4545
  • [26] Seismic performance of circular concrete-filled steel tube columns reinforced with inner latticed steel angles
    Yang, Zi-Ming
    Chen, Ju
    Wang, Fangying
    Wang, Jun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 205
  • [27] Uniaxial behaviour of sand concrete-filled steel tube columns
    Madi, Wafa
    Ihaddoudene, Abd Nacer Touati
    da Costa-Neves, Luis Filipe
    Goncalves da Silva Vellasco, Pedro Colmar
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2019, 172 (04) : 278 - 288
  • [28] Performance investigation of square concrete-filled steel tube columns
    Bing Chen
    Xiao Liu
    Siping Li
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2011, 26 : 730 - 736
  • [29] Strength Calculation of Short Concrete-filled Steel Tube Columns
    Anatoly Leonidovich Krishan
    Mariia Anatolyevna Astafeva
    Elvira Petrovna Chernyshova
    International Journal of Concrete Structures and Materials, 2018, 12
  • [30] Analysis on fire resistance of concrete-filled steel tube columns
    Yang, Hua
    Han, Lin-Hai
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2003, 35 (SUPPL.): : 93 - 96