Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

被引:6
|
作者
Brown, Ari-David [1 ]
Hsieh, Wen-Ting [1 ]
Moseley, S. Harvey [1 ]
Stevenson, Thomas R. [1 ]
U-yen, Kongpop [1 ]
Wollack, Edward J. [1 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
关键词
MKID; far-infrared; microwave; cryogenic detectors; absorber coupled;
D O I
10.1117/12.857281
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and far-infrared astronomy. These sensors are comprised of arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5 mu m thick silicon membrane, which are optimized for optical coupling. The detector elements are supported on a 380 mu m thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and by employing an appropriate surface impedance and effective filling fraction. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.
引用
收藏
页数:10
相关论文
共 25 条
  • [21] GaAs cryogenic readout electronics for high impedance detector arrays for far-infrared and submillimeter wavelength region
    Nagata, H.
    Matsuo, H.
    Hibi, Y.
    Kobayashi, J.
    Nakahashi, M.
    Ikeda, H.
    Fujiwara, M.
    CRYOGENICS, 2009, 49 (11) : 676 - 680
  • [22] Fabrication of slot antenna array coupled warm carrier far-infrared radiation detectors
    Yasuoka, Y
    Suzuki, K
    MICROELECTRONIC ENGINEERING, 2003, 67-8 : 528 - 533
  • [23] Optical modeling techniques for multimode horn-coupled power detectors for submillimeter and far-infrared astronomy
    Thomas, Christopher N.
    Withington, Stafford
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2013, 30 (08) : 1703 - 1713
  • [24] Evaluation of a sub-millimeter resolution PET detector with a 1.2 mm pitch TSV-MPPC array one-to-one coupled to LFS scintillator crystals and individual signal readout
    Ota, R.
    Omura, T.
    Yamada, R.
    Miwa, T.
    Watanabe, M.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [25] Performance evaluation of a sub-millimeter spatial resolution PET detector module using a digital silicon photomultiplier coupled LGSO array
    Leem, Hyun Tae
    Choi, Yong
    Kim, Kyu Born
    Lee, Sangwon
    Yamamoto, Seiichi
    Yeom, Jung-Yeol
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 846 : 18 - 22