Outcome and right ventricle remodelling after valve replacement for pulmonic stenosis

被引:2
|
作者
Laflamme, Emilie [1 ]
Wald, Rachel M. [1 ]
Roche, S. Lucy [1 ]
Silversides, Candice K. [1 ]
Thorne, Sara A. [1 ]
Colman, Jack M. [1 ]
Benson, Lee [1 ]
Osten, Mark [1 ]
Horlick, Eric [1 ]
Oechslin, Erwin [1 ]
Alonso-Gonzalez, Rafael [1 ]
机构
[1] Univ Hlth Network, Toronto ACHD Program, Toronto, ON M5G 2N2, Canada
关键词
heart defects; congenital; pulmonary valve stenosis; pulmonary valve insufficiency; CONGENITAL HEART-DISEASE; FOLLOW-UP; TETRALOGY; REPAIR; CHILDREN; ADULTS; IMPACT;
D O I
10.1136/heartjnl-2021-320121
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Complications and need for reinterventions are frequent in patients with pulmonary valve stenosis (PVS). Pulmonary regurgitation is common, but no data are available on outcome after pulmonary valve replacement (PVR). Methods We performed a retrospective analysis of 215 patients with PVS who underwent surgical valvotomy or balloon valvuloplasty. Incidence and predictors of reinterventions and complications were identified. Right ventricle (RV) remodelling after PVR was also assessed. Results After a median follow-up of 38.6 (30.9-49.4) years, 93% of the patients were asymptomatic. Thirty-nine patients (18%) had at least one PVR. Associated right ventricular outflow tract (RVOT) intervention and the presence of an associated defect were independent predictors of reintervention (OR: 4.1 (95% CI 1.5 to 10.8) and OR: 3.6 (95% CI 1.9 to 6.9), respectively). Cardiovascular death occurred in 2 patients, and 29 patients (14%) had supraventricular arrhythmia. Older age at the time of first intervention and the presence of an associated defect were independent predictors of complications (OR: 1.0 (95% CI 1.0 to 1.1) and OR: 2.1 (95% CI 1.1 to 4.2), respectively). In 16 patients, cardiac magnetic resonance before and after PVR was available. The optimal cut-off values for RV volume normalisation were 193 mL/m(2) for RV end-diastolic volume indexed(sensitivity 80%, specificity 64%) and 100 mL/m(2) for RV end-systolic volume indexed(sensitivity 80%, specificity 56%). Conclusions Previous RVOT intervention, presence of an associated defect and older age at the time of first repair were predictors of outcome. More data are needed to guide timing of PVR, and extrapolation of tetralogy of Fallot guidelines to this population is unlikely to be appropriate.
引用
收藏
页码:1290 / 1295
页数:6
相关论文
共 50 条
  • [31] Regional right ventricular function in patients with severe aortic valve stenosis before and after aortic valve replacement and its impact on clinical outcome
    Herrmann, S. H.
    Strotmann, J. S.
    Niemann, M. N.
    Lange, V. L.
    Beer, M. B.
    Gattenloehner, S. G.
    Voelker, W. V.
    Ertl, G. E.
    Weidemann, F. W.
    EUROPEAN HEART JOURNAL, 2009, 30 : 682 - 682
  • [32] DOUBLE-OUTLET RIGHT VENTRICLE WITHOUT PULMONIC STENOSIS - SURGICAL CONSIDERATIONS AND RESULTS OF OPERATION
    GOMES, MMR
    WEIDMAN, WH
    MCGOON, DC
    DANIELSON, GK
    CIRCULATION, 1971, 43 (05) : I31 - +
  • [33] Early surgical outcome of pulmonary valve replacement in patients with previous right ventricle outflow tract reconstruction
    Saritas, Bulent
    Ozker, Emre
    Ozkan, Murat
    Sarisoy, Ozlam
    Ayabakan, Canan
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 25 (03): : 363 - 367
  • [34] DOUBLE-OUTLET RIGHT VENTRICLE FOR RELIEF OF PULMONIC STENOSIS IN DOGS - AN EXPERIMENTAL-STUDY
    WHITING, PG
    BREZNOCK, EM
    PENDRAY, DL
    STRACK, DR
    VETERINARY SURGERY, 1984, 13 (02) : 64 - 70
  • [35] An unusual appearance of the right ventricle following replacement of the pulmonary valve
    Coats, Louise
    Khambadkone, Sachin
    Sullivan, Ian D.
    CARDIOLOGY IN THE YOUNG, 2006, 16 (04) : 403 - 404
  • [36] AORTIC VALVE REPLACEMENT AND THE RIGHT VENTRICLE-THE PLOT THICKENS
    Dobson, Laura E.
    Musa, Tarique A.
    Greenwood, John P.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (03): : 742 - +
  • [37] Global Strain in Severe Aortic Valve Stenosis Relation to Clinical Outcome After Aortic Valve Replacement
    Dahl, Jordi S.
    Videbaek, Lars
    Poulsen, Mikael K.
    Rudbaek, Torsten R.
    Pellikka, Patricia A.
    Moller, Jacob E.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (05) : 613 - 620
  • [38] COMPUTATIONAL MODELING OF THE RIGHT VENTRICLE IN REPAIRED TETRALOGY OF FALLOT, BEFORE AND AFTER PULMONARY VALVE REPLACEMENT
    Loke, Yue-Hin
    Yildiran, Ibrahim
    Capuano, Francesco
    Olivieri, Laura
    Balaras, Ilias
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1367 - 1367
  • [39] Mitral valve replacement in mitral stenosis; the problem of small left ventricle
    Hesham Alkady
    Ahmed Saber
    Sobhy Abouramadan
    Ahmed Elnaggar
    Sherif Nasr
    Eman Mahmoud
    Journal of Cardiothoracic Surgery, 15
  • [40] Mitral valve replacement in mitral stenosis; the problem of small left ventricle
    Alkady, Hesham
    Saber, Ahmed
    Abouramadan, Sobhy
    Elnaggar, Ahmed
    Nasr, Sherif
    Mahmoud, Eman
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)