Experimental Evaluation and Modeling of Corroded Reinforced Concrete Columns

被引:39
|
作者
Yalciner, Hakan [1 ,2 ]
Kumbasaroglu, Atila [1 ,3 ]
机构
[1] Erzincan Binali Yildirim Univ, Dept Civil Engn, Erzincan, Turkey
[2] Struct Res Ctr, Dept Civil Engn, Erzincan, Turkey
[3] Erzincan Binali Yildirim Univ, Res Corros Studies, Erzincan, Turkey
关键词
assessment; column; corrosion; reinforcement bar; seismic; SEISMIC PERFORMANCE; CORROSION INFLUENCE; CYCLIC BEHAVIOR; BRIDGE PIERS; BARS;
D O I
10.14359/51721372
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 30 full-scale reinforced concrete (RC) columns were tested to develop models for the prediction of the structural behavior of corroded RC columns. Of these, 25 RC columns were tested under cyclic loading for two different applied axial load ratios-namely, 0.20 and 0.40-at three concrete strength levels-namely, 9, 27, and 37 MPa (1305, 3915, and 5365 psi)-and at four corrosion levels. Five RC columns were loaded monotonically with an axial load ratio of 0.20 at four corrosion levels to calculate the damage index. The actual corrosion levels were obtained by breaking the concrete and extracting all the reinforcing bars. The test results demonstrated that the ductility ratios of the corroded RC columns, which were not determined in accordance with energy-based or bilateral failure criteria, could be misleading. The determined energy dissipation capacity and damage index of the columns further revealed the corrosion effects.
引用
收藏
页码:61 / 76
页数:16
相关论文
共 50 条
  • [11] Experimental Studies on the Mechanical Performances of Corroded Reinforced Concrete Columns Retrofitted with FRP
    Zhou Yingwu
    Wu Lingyi
    Sui Lili
    Xing Feng
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 726 - 730
  • [12] The Experimental Study on Reinforced Concrete Short-Columns Restrained by Corroded Stirrups
    Li, Qiang
    Niu, Ditao
    Liu, Lei
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 1376 - 1379
  • [13] Experimental study on seismic behavior of corroded reinforced concrete columns strengthened with concrete jacket and CFRP
    Li, Jinbo
    Gong, Jinxin
    Wang, Lihuan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2009, 42 (04): : 17 - 26
  • [14] Residual Loading Capacity of Corroded Reinforced Concrete Columns
    Chen H.
    Jiang Y.
    Liu C.
    Tiedao Xuebao/Journal of the China Railway Society, 2023, 45 (04): : 166 - 174
  • [15] Fire performance of aged and corroded reinforced concrete columns
    Chandra, Shashank
    Sharma, Umesh Kumar
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [16] Experimental study on the seismic behavior of ECE corroded reinforced concrete short pier columns
    Li, Yalin
    Zheng, Shansuo
    Shang, Zhigang
    Chen, Jiachen
    Wang, Dongyu
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 348
  • [17] Experimental Study to Predict Bond-Slip Behavior of Corroded Reinforced Concrete Columns
    Yalciner, Hakan
    Kumbasaroglu, Atila
    ACI STRUCTURAL JOURNAL, 2022, 119 (05) : 111 - 128
  • [18] An experimental evaluation on structural performance level of corroded reinforced concrete frames
    Turan, Ahmet Ihsan
    Ayaz, Yasar
    Yalciner, Hakan
    Kumbasaroglu, Atila
    ENGINEERING STRUCTURES, 2025, 325
  • [19] Computational model for bearing capacity of corroded reinforced concrete columns
    Chen, Xiao-Chen
    Liu, Xi-La
    Song, Xiao-Bing
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2008, 42 (06): : 985 - 988
  • [20] Mesoscopic investigation on seismic performance of corroded reinforced concrete columns
    Jin, Liu
    Li, Yanxi
    Zhang, Renbo
    Du, Xiuli
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2022, 21 (04) : 969 - 985