Accuracy and quality assessment of 454 GS-FLX Titanium pyrosequencing

被引:269
|
作者
Gilles, Andre [2 ]
Meglecz, Emese [2 ]
Pech, Nicolas [2 ]
Ferreira, Stephanie [3 ]
Malausa, Thibaut [4 ]
Martin, Jean-Francois [1 ]
机构
[1] INRA IRD Cirad Montpellier SupAgro, CBGP, UMR, Campus Int Baillarguet,CS 30016, F-34988 Montferrier Sur Lez, France
[2] Aix Marseille Univ, CNRS, IRD,Ctr St Charles, UMR IMEP 6116,Equipe Evolut Genome Environm, F-13331 Marseille 3, France
[3] Genoscreen, Genom Platform & R&D, F-59000 Lille, France
[4] INRA, UMR 1301, Equipe BPI, F-06903 Sophia Antipolis, France
来源
BMC GENOMICS | 2011年 / 12卷
关键词
RARE BIOSPHERE; NEW-GENERATION; DISCOVERY; DIVERSITY; WRINKLES; ERRORS; RATES;
D O I
10.1186/1471-2164-12-245
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: The rapid evolution of 454 GS-FLX sequencing technology has not been accompanied by a reassessment of the quality and accuracy of the sequences obtained. Current strategies for decision-making and error-correction are based on an initial analysis by Huse et al. in 2007, for the older GS20 system based on experimental sequences. We analyze here the quality of 454 sequencing data and identify factors playing a role in sequencing error, through the use of an extensive dataset for Roche control DNA fragments. Results: We obtained a mean error rate for 454 sequences of 1.07%. More importantly, the error rate is not randomly distributed; it occasionally rose to more than 50% in certain positions, and its distribution was linked to several experimental variables. The main factors related to error are the presence of homopolymers, position in the sequence, size of the sequence and spatial localization in PT plates for insertion and deletion errors. These factors can be described by considering seven variables. No single variable can account for the error rate distribution, but most of the variation is explained by the combination of all seven variables. Conclusions: The pattern identified here calls for the use of internal controls and error-correcting base callers, to correct for errors, when available (e. g. when sequencing amplicons). For shotgun libraries, the use of both sequencing primers and deep coverage, combined with the use of random sequencing primer sites should partly compensate for even high error rates, although it may prove more difficult than previous thought to distinguish between low-frequency alleles and errors.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Assessing the feasibility of GS FLX Pyrosequencing for sequencing the Atlantic salmon genome
    Quinn, Nicole L.
    Levenkova, Natasha
    Chow, William
    Bouffard, Pascal
    Boroevich, Keith A.
    Knight, James R.
    Jarvie, Thomas P.
    Lubieniecki, Krzysztof P.
    Desany, Brian A.
    Koop, Ben F.
    Harkins, Timothy T.
    Davidson, William S.
    BMC GENOMICS, 2008, 9 (1)
  • [32] Evaluation of human gene variant detection in amplicon pools by the GS-FLX parallel Pyrosequencer
    Bordoni, Roberta
    Bonnal, Raoul
    Rizzi, Ermanno
    Carrera, Paola
    Benedetti, Sara
    Cremonesi, Laura
    Stenirri, Stefania
    Colombo, Alessio
    Montrasio, Cristina
    Bonalumi, Sara
    Albertini, Alberto
    Bernardi, Luigi Rossi
    Ferrari, Maurizio
    De Bellis, Gianluca
    BMC GENOMICS, 2008, 9 (1)
  • [33] COMPLETE SEQUENCING OF THE CFTR GENE USING NEXT-GENERATION GS-FLX SEQUENCING IN A DIAGNOSTIC SETTING
    Cuppens, H.
    Vliegen, L.
    Cassiman, J.
    PEDIATRIC PULMONOLOGY, 2009, : 274 - 274
  • [34] Transcriptome Sequencing and De Novo Analysis of the Copepod Calanus sinicus Using 454 GS FLX
    Ning, Juan
    Wang, Minxiao
    Li, Chaolun
    Sun, Song
    PLOS ONE, 2013, 8 (05):
  • [35] High-Throughput Analysis and Characterization of Astragalus membranaceus Transcriptome Using 454 GS FLX
    Liu, Xiu-Bo
    Ma, Ling
    Zhang, Ai-Hua
    Zhang, Yan-He
    Jiang, Jing
    Ma, Wei
    Zhang, Lei-Ming
    Ren, Wei-Chao
    Kong, Xiang-Jun
    PLOS ONE, 2014, 9 (05):
  • [36] ANALYSIS OF MIXTURES USING DEEP SEQUENCING OF HLA GENES WITH THE 454 GS FLX SEQUENCING SYSTEM
    Holcomb, Cherie L.
    Rastrou, Melinda
    Hoglund, Bryan
    Goodridge, Damian
    Salomon, Daniel R.
    Erlich, Henry A.
    TISSUE ANTIGENS, 2013, 81 (05): : 347 - 348
  • [37] Development of eight microsatellite loci from the Green and Golden Bell Frog (Litoria aurea) through GS-FLX pyrosequencing and cross-amplification with other species of the Litoria aurea species group
    DeBoo, Matthew L.
    Bertozzi, Terry
    Donnellan, Stephen
    Mahony, Michael J.
    CONSERVATION GENETICS RESOURCES, 2012, 4 (04) : 1003 - 1005
  • [38] Deep sequencing of HIV: variant detection by Illumina MiSeq and Roche 454 GS FLX+
    Bentley, L. G.
    Mohsen, M. S. A.
    Liegler, T.
    Grant, R. M.
    ANTIVIRAL THERAPY, 2013, 18 : A133 - A133
  • [39] Development of eight microsatellite loci from the Green and Golden Bell Frog (Litoria aurea) through GS-FLX pyrosequencing and cross-amplification with other species of the Litoriaaurea species group
    Matthew L. DeBoo
    Terry Bertozzi
    Stephen Donnellan
    Michael J. Mahony
    Conservation Genetics Resources, 2012, 4 : 1003 - 1005
  • [40] Simultaneous Mutation and Copy Number Variation (CNV) Detection by Multiplex PCR-Based GS-FLX Sequencing
    Goossens, Dirk
    Moens, Lotte N.
    Nelis, Eva
    Lenaerts, An-Sofie
    Glassee, Wim
    Kalbe, Andreas
    Frey, Bruno
    Kopal, Guido
    De Jonghe, Peter
    De Rijk, Peter
    Del-Favero, Jurgen
    HUMAN MUTATION, 2009, 30 (03) : 472 - 476