Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

被引:33
|
作者
Stolzmann, Paul [1 ]
Goetti, Robert [1 ]
Baumueller, Stephan [1 ]
Plass, Andre [2 ]
Falk, Volkmar [2 ]
Scheffel, Hans [1 ]
Feuchtner, Gudrun [1 ]
Marincek, Borut [1 ]
Alkadhi, Hatem [1 ,3 ,4 ]
Leschka, Sebastian [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02114 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
基金
瑞士国家科学基金会;
关键词
Dual-source CT; Coronary angiography; Diagnostic performance; Low heart rate; Prospectively ECG-gated; Retrospectively ECG-gated; MULTISLICE COMPUTED-TOMOGRAPHY; DUAL-SOURCE CT; ARTERY-DISEASE; DIAGNOSTIC-ACCURACY; IMAGE QUALITY; SHOOT MODE;
D O I
10.1016/j.ejrad.2009.12.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates <= 70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 +/- 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 +/- 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates <= 70 bpm while being associated with a lower mean effective radiation dose. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [41] Low dose coronary CT angiography using prospective ECG-Triggering: Impact of mean heart rate and heart variability on image quality.
    Herzog, Bernhard Alexandre B. A.
    Husmann, L.
    Burkhard, N.
    Valenta, I.
    Gaemperli, O.
    Wyss, C. A.
    Landmesser, U.
    Kaufmann, P. A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S84 - S84
  • [42] Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
    Tobias F. Jakobs
    Bernd J. Wintersperger
    Peter Herzog
    Thomas Flohr
    Christoph Suess
    Andreas Knez
    Maximilian F. Reiser
    Christoph R. Becker
    European Radiology, 2003, 13 : 1923 - 1930
  • [43] Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
    Jakobs, TF
    Wintersperger, BJ
    Herzog, P
    Flohr, T
    Suess, C
    Knez, A
    Reiser, MF
    Becker, CR
    EUROPEAN RADIOLOGY, 2003, 13 (08) : 1923 - 1930
  • [44] Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality
    Ippolito, Davide
    Fior, Davide
    Franzesi, Cammillo Talei
    Riva, Luca
    Casiraghi, Alessandra
    Sironi, Sandro
    RADIOLOGIA MEDICA, 2017, 122 (12): : 893 - 901
  • [45] Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality
    Davide Ippolito
    Davide Fior
    Cammillo Talei Franzesi
    Luca Riva
    Alessandra Casiraghi
    Sandro Sironi
    La radiologia medica, 2017, 122 : 893 - 901
  • [46] Optimierung der Zeitauflösung in der CT mittels retrospektivem EKG-GatingOptimization of temporal resolution in CT using retrospective ECG-gating
    J. M. Boese
    M. L. Bahner
    J. Albers
    G. van Kaick
    Der Radiologe, 2000, 40 (2): : 123 - 129
  • [47] Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT
    Symersky, Petr
    Habets, Jesse
    Westers, Paul
    de Mol, Bas A. J. M.
    Prokop, Mathias
    Budde, Ricardo P. J.
    EUROPEAN RADIOLOGY, 2012, 22 (06) : 1271 - 1277
  • [48] Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT
    Petr Symersky
    Jesse Habets
    Paul Westers
    Bas A. J. M. de Mol
    Mathias Prokop
    Ricardo P. J. Budde
    European Radiology, 2012, 22 : 1271 - 1277
  • [49] Application of prospective ECG-gated multiphase scanning for coronary CT in children with different heart rates
    Tang, Shilong
    Zhang, Guanping
    Chen, Zhuo
    Liu, Xianfan
    He, Ling
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (10) : 946 - 955
  • [50] Application of prospective ECG-gated multiphase scanning for coronary CT in children with different heart rates
    Shilong Tang
    Guanping Zhang
    Zhuo Chen
    Xianfan Liu
    Ling He
    Japanese Journal of Radiology, 2021, 39 : 946 - 955