A framework for automated contour quality assurance in radiation therapy including adaptive techniques

被引:56
|
作者
Altman, M. B. [1 ]
Kavanaugh, J. A. [1 ]
Wooten, H. O. [1 ]
Green, O. L. [1 ]
DeWees, T. A. [1 ]
Gay, H. [1 ]
Thorstad, W. L. [1 ]
Li, H. [1 ]
Mutic, S. [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 13期
关键词
contouring; quality assurance; adaptive radiation therapy; treatment planning; CANCER RADIOTHERAPY; GEOMETRIC CHANGES; ATLAS SELECTION; LUNG-CANCER; SEGMENTATION; DELINEATION; VOLUME; MULTICENTER; VARIABILITY; VALIDATION;
D O I
10.1088/0031-9155/60/13/5199
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contouring of targets and normal tissues is one of the largest sources of variability in radiation therapy treatment plans. Contours thus require a time intensive and error-prone quality assurance (QA) evaluation, limitations which also impair the facilitation of adaptive radiotherapy (ART). Here, an automated system for contour QA is developed using historical data (the 'knowledge base'). A pilot study was performed with a knowledge base derived from 9 contours each from 29 head-and-neck treatment plans. Size, shape, relative position, and other clinically-relevant metrics and heuristically derived rules are determined. Metrics are extracted from input patient data and compared against rules determined from the knowledge base; a computer-learning component allows metrics to evolve with more input data, including patient specific data for ART. Nine additional plans containing 42 unique contouring errors were analyzed. 40/42 errors were detected as were 9 false positives. The results of this study imply knowledge-based contour QA could potentially enhance the safety and effectiveness of RT treatment plans as well as increase the efficiency of the treatment planning process, reducing labor and the cost of therapy for patients.
引用
收藏
页码:5199 / 5209
页数:11
相关论文
共 50 条
  • [31] QUALITY ASSURANCE OF RADIATION-THERAPY TREATMENT UNITS
    PURDY, JA
    MEDICAL PHYSICS, 1983, 10 (04) : 562 - 563
  • [32] Telemedicine in quality assurance in distributed radiation therapy services
    Olsen, DR
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S202 - S202
  • [33] KENQUAD - A QUALITY ASSURANCE DEVICE FOR RADIATION-THERAPY
    ANVRET, K
    AGOSTINELLI, AG
    GIGNAC, CE
    NATH, R
    SCHULZ, RJ
    MEDICAL PHYSICS, 1980, 7 (04) : 441 - 441
  • [34] Quality assurance procedures for stereotactic body radiation therapy
    Calvin, James M.
    Bednarz, Greg
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S122 - S125
  • [35] Radiation therapy port films: A quality assurance study
    Morgan, TL
    Banks, DA
    Kagan, AR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (01): : 223 - 227
  • [36] Strategies for quality assurance of intensity modulated radiation therapy
    Benedek, Hunor
    Isacsson, Ulf
    Olevik-Dunder, Maria
    Westermark, Mathias
    Hallstrom, Per
    Olofsson, Jorgen
    Gustafsson, Magnus
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [37] Quality Assurance for Image-Guided Radiation Therapy
    Bissonnette, J. P.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [38] A method for evaluating quality assurance needs in radiation therapy
    Huq, M. Saiful
    Fraass, Benedick A.
    Dunscombe, Peter B.
    Gibbons, John P., Jr.
    Ibbott, Geoffrey S.
    Medin, Paul M.
    Mundt, Arno
    Mutic, Sassa
    Palta, Jatinder R.
    Thomadsen, Bruce R.
    Williamson, Jeffrey F.
    Yorke, Ellen D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S170 - S173
  • [39] Radiation therapy port films: a quality assurance study
    Morgan, Thomas L.
    Banks, Dorothy A.
    Kagan, A. Robert
    International Journal of Radiation Oncology, Biology, Physics, 42 (01): : 223 - 227
  • [40] Stability Test for MRI Quality Assurance in Radiation Therapy
    McClain, B.
    Curcuru, A.
    Green, O.
    Mutic, S.
    Gach, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 3077 - 3077