A framework for automated contour quality assurance in radiation therapy including adaptive techniques

被引:56
|
作者
Altman, M. B. [1 ]
Kavanaugh, J. A. [1 ]
Wooten, H. O. [1 ]
Green, O. L. [1 ]
DeWees, T. A. [1 ]
Gay, H. [1 ]
Thorstad, W. L. [1 ]
Li, H. [1 ]
Mutic, S. [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 13期
关键词
contouring; quality assurance; adaptive radiation therapy; treatment planning; CANCER RADIOTHERAPY; GEOMETRIC CHANGES; ATLAS SELECTION; LUNG-CANCER; SEGMENTATION; DELINEATION; VOLUME; MULTICENTER; VARIABILITY; VALIDATION;
D O I
10.1088/0031-9155/60/13/5199
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contouring of targets and normal tissues is one of the largest sources of variability in radiation therapy treatment plans. Contours thus require a time intensive and error-prone quality assurance (QA) evaluation, limitations which also impair the facilitation of adaptive radiotherapy (ART). Here, an automated system for contour QA is developed using historical data (the 'knowledge base'). A pilot study was performed with a knowledge base derived from 9 contours each from 29 head-and-neck treatment plans. Size, shape, relative position, and other clinically-relevant metrics and heuristically derived rules are determined. Metrics are extracted from input patient data and compared against rules determined from the knowledge base; a computer-learning component allows metrics to evolve with more input data, including patient specific data for ART. Nine additional plans containing 42 unique contouring errors were analyzed. 40/42 errors were detected as were 9 false positives. The results of this study imply knowledge-based contour QA could potentially enhance the safety and effectiveness of RT treatment plans as well as increase the efficiency of the treatment planning process, reducing labor and the cost of therapy for patients.
引用
收藏
页码:5199 / 5209
页数:11
相关论文
共 50 条
  • [1] A quality assurance phantom for motion adaptive radiation therapy
    Gallagher, C.
    Van Dyk, J.
    Lechtman, E.
    Black, S.
    Gaede, S.
    Kron, T.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S50 - S50
  • [2] A Framework of Automatic Contour Quality Validation for MRI-Guided Online Adaptive Radiation Therapy
    Zhang, Y.
    Ceballos, F.
    Ahunbay, E.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E500 - E500
  • [3] Automated Quality Assurance for Image-Guided Radiation Therapy
    Schreibmann, Eduard
    Elder, Eric
    Fox, Tim
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 71 - 79
  • [4] Toward automated quality assurance for intensity-modulated radiation therapy
    Low, DA
    Dempsey, JF
    Markman, J
    Mutic, S
    Klein, EE
    Sohn, JW
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02): : 443 - 452
  • [5] Automated delivery and quality assurance of a modulated electron radiation therapy plan
    Connell, T.
    Alexander, A.
    Papaconstadopoulos, P.
    Serban, M.
    Devic, S.
    Seuntjens, J.
    MEDICAL PHYSICS, 2014, 41 (08) : 5 - 6
  • [6] Automated delivery and quality assurance of modulated electron radiation therapy for breast
    Connell, T.
    Papaconstadopoulos, P.
    Alexander, A.
    Serban, M.
    Devic, S.
    Seuntjens, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S284 - S284
  • [7] Implementation of a Machine Learning-Based Automatic Contour Quality Assurance Tool for Online Adaptive Radiation Therapy of Prostate Cancer
    Zhang, J.
    Ates, O.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E668 - E668
  • [8] Towards automated quality assurance for intensity modulated radiation therapy: Film densitometry
    Low, DA
    Markman, J
    Dempsey, JF
    Mutic, S
    Klein, EE
    Grigereit, TE
    Purdy, JA
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 184 - 187
  • [9] Automated Processing of Sensitometry Data for Radiation Therapy Treatment Planner and Quality Assurance
    Healy, A.
    Levy, J.
    Fredriksson, J.
    Olafsdottir, H.
    Kristinsson, S.
    Dalbow, G.
    Pawlicki, T.
    Goodenough, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Automated Plan Quality Ranking for Online Adaptive Radiation Therapy
    Ceballos, F.
    Lim, S.
    Wang, Z.
    Zhang, J.
    Nasief, H.
    Ahunbay, E.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E422 - E422