Surface dose measurement for helical tomotherapy

被引:8
|
作者
Snir, Jonatan A. [1 ]
Mosalaei, Homeira [1 ]
Jordan, Kevin [1 ,2 ,3 ]
Yartsev, Slav [1 ,2 ,3 ]
机构
[1] London Hlth Sci Ctr, London Reg Canc Program, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Oncol, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 3K7, Canada
关键词
helical tomotherapy; OSL dosimeter; MOSFET dosimeter; skin dose; MOSFET; HEAD;
D O I
10.1118/1.3592021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the surface dose measurements made by different dosimeters for the helical tomotherapy (HT) plan in the case of the target close to the surface. Methods: Surface dose measurements in different points for the HT plan to deliver 2 Gy to the planning target volume (PTV) at 5 mm below the surface of the cylindrical phantom were performed by radiochromic films, single use metal oxide semiconductor field-effect transistor (MOSFET) dosimeters, silicon IVD QED diode, and optically stimulated luminescence (OSL) dosimeters. Results: The measured doses by all dosimeters were within 12 +/- 8% difference of each other. Conclusions: Radiochromic films, EBT, and EBT(2), provide high spatial resolution, although it is difficult to get accurate measurements of dose. Both the OSL and QED measured similar dose to that of the MOSFET detectors. The QED dosimeter is promising as a reusable on-line wireless dosimeter, while the OSL dosimeters are easier to use, require minimum setup time and are very precise. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3592021]
引用
收藏
页码:3104 / 3107
页数:4
相关论文
共 50 条
  • [1] Surface Dose in the Treatment of Breast Cancer with Helical Tomotherapy
    Zibold, Felix
    Sterzing, Florian
    Sroka-Perez, Gabriele
    Schubert, Kai
    Wagenknecht, Katja
    Major, Gerald
    Debus, Juergen
    Herfarth, Klaus
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (09) : 574 - 581
  • [2] Measurement-guided volumetric dose reconstruction for helical tomotherapy
    Stambaugh, Cassandra
    Nelms, Benjamin
    Wolf, Theresa
    Mueller, Richard
    Geurts, Mark
    Opp, Daniel
    Zhang, Geoffrey
    Moros, Eduardo
    Feygelman, Vladimir
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 302 - 321
  • [3] Cancer treatment with helical tomotherapy - Analysis of dose distributions, surface dose and toxicity
    Sterzing, F.
    Zibold, F.
    Sroka-Perez, G.
    Debus, J.
    Schubert, K.
    Herfarth, K. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S513 - S514
  • [4] Investigations of peripheral dose for helical tomotherapy
    Lissner, Steffen
    Schubert, Kai
    Wiezorek, Tilo
    Sterzing, Florian
    Herfarth, Klaus
    Sroka-Perez, Gabriele
    Debus, Juergen
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (04): : 324 - 331
  • [5] Helical tomotherapy superficial dose measurements
    Ramsey, Chester R.
    Seibert, Rebecca M.
    Robison, Benjamin
    Mitchell, Martha
    MEDICAL PHYSICS, 2007, 34 (08) : 3286 - 3293
  • [6] Measurement of shielding requirements for helical tomotherapy
    Seibert, R
    Mahan, S
    Ramsey, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2163 - 2163
  • [7] Target Change Effect on Surface Dose of Treatment and Imaging Helical Tomotherapy Beams
    Ehler, E.
    Gerbi, B.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Helical tomotherapy for moving objects - Analysis of the surface dose for the radiotherapy of the Mamma Carcinoma
    Zibold, F.
    Sterzing, F.
    Sroka-Perez, G.
    Schubert, K.
    Wagenknecht, K.
    Debus, J.
    Herfarth, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 99 - 99
  • [9] Dose reconstruction quality assurance for helical tomotherapy
    Chase, D.
    Ramsey, C.
    Seibert, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2256 - 2256
  • [10] Whole-body dose for helical tomotherapy
    Goddu, S.
    Mutic, S.
    Grigsby, J.
    Santanam, L.
    Low, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2150 - 2150