Normothermic ex vivo perfusion of the limb allograft depletes donor leukocytes prior to transplantation

被引:10
|
作者
Amin, K. R. [2 ,4 ]
Stone, J. P. [1 ,2 ,3 ]
Kerr, J. C. [1 ,2 ]
Wong, J. K. [4 ,5 ]
Fildes, J. E. [1 ,2 ,3 ]
机构
[1] 3F66,Block 3,Alderley Park, Nether Alderley SK10 4TG, Cheshire, England
[2] Univ Manchester, Fac Biol Med & Hlth, Manchester Acad Hlth Sci Ctr,Ex Vivo Lab, Sch Biol Sci,Div Cell Matrix Biol & Regenerat Med, Manchester M13 9NT, Lancs, England
[3] Manchester Univ NHS Fdn Trust, Transplant Ctr, Manchester M23 9LT, Lancs, England
[4] Univ Manchester, Fac Biol Med & Hlth, Sch Biol Sci,Manchester Acad Hlth Sci Ctr, Div Cell Matrix Biol & Regenerat Med,Blond Mclndo, Manchester, Lancs, England
[5] Manchester Univ NHS Fdn Trust, Wythenshawe Hosp, Dept Plast Surg & Burns, Manchester, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Vascularised composite allograft; Ex vivo normothermic perfusion; Passenger leukocytes; Acute rejection; COMPOSITE TISSUE ALLOGRAFT; ALLORECOGNITION; REJECTION; SURVIVAL; PATHWAYS; REMOVAL; SYSTEM; MUSCLE; CELLS;
D O I
10.1016/j.bjps.2021.03.071
中图分类号
R61 [外科手术学];
学科分类号
摘要
kinetics of donor leucocyte extravasation, cytokine secretion and cell-free DNA was charac-terised in the circulating perfusate. Results: Flow cytometry revealed increasing populations of viable leukocytes over time, reach-ing 49 billion leukocytes by 6 h. T (3.0 x 10 9 cells) and B cells (3.1 x 10 8 cells) lymphocytes, monocytes (2.7 x 10 9 cells), granulocytes (8.1 x 10 9 cells), NK (6.3 x 10 8 ) and gamma delta (8.1 x 10 8 ) cells were all identified. Regulatory T cells comprised a minor population (1.6 x 10 7 cells). There was a cumulative increase in pro-inflammatory cytokines suggesting that the donor limb has the capacity to elicit significant inflammatory responses that could contribute to leucocyte activation and diapedesis. Conclusion: EVNP not only acts as a preservation tool, but could also be utilized to immun-odeplete the VCA allograft prior to transplantation. This has clinical implications to mitigate acute rejection and prevent graft dysfunction and supports the future application of machine perfusion in graft preservation and immune modulation. (c) 2021 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by El-sevier Ltd. All rights reserved.
引用
收藏
页码:2969 / 2976
页数:8
相关论文
共 50 条
  • [21] The first clinical series of ex-vivo normothermic perfusion (EVNP) in marginal donor kidney transplantation
    Hosgood, S. A.
    Crotty, C.
    Nicholson, M. L.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 32 - 32
  • [22] Normothermic ex vivo perfusion of deceased donor kidneys and its clinical potential in kidney transplantation outcomes
    Unes, Meghan
    Kurashima, Kento
    Caliskan, Yasar
    Portz, Edward
    Jain, Ajay
    Nazzal, Mustafa
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2023, 46 (12): : 618 - 628
  • [23] Comment on "Ex-vivo flush of the limb allograft reduces inflammatory burden prior to transplantation"
    Wilks, Daniel
    Baker, Richard
    Kay, Simon
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2018, 71 (02): : 147 - 148
  • [24] Metabolomic Profiling During Ex-Vivo Normothermic Perfusion Prior to Heart Transplantation Defines Patterns of Substrate Utilization and Correlates with Markers of Allograft Injury
    Truby, L. K.
    Bowles, D.
    Casalinova, S.
    Kwee, L. C.
    Ilkayeva, O.
    Muehlbauer, M.
    Huebner, J.
    Holley, C.
    DeVore, A. D.
    Patel, C.
    Kang, L.
    Pla, M. Mendiola
    Gross, R.
    McGarrah, R. W.
    Schroder, J.
    Milano, C.
    Shah, S. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S77 - S77
  • [25] First in Man Renal Transplantation After Ex Vivo Normothermic Perfusion
    Hosgood, Sarah A.
    Nicholson, Michael L.
    TRANSPLANTATION, 2011, 92 (07) : 735 - 738
  • [26] Normothermic and subnormothermic ex-vivo liver perfusion in liver transplantation
    Goldaracena, Nicolas
    Barbas, Andrew S.
    Selzner, Markus
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 315 - 321
  • [27] Assessment of Graft Metabolism and Function During Normothermic ex vivo Liver Perfusion - Objective Assessment Prior to Transplantation
    Echeverri, J.
    Cleland, S.
    Kaths, M.
    Linares, I.
    Rosales, R.
    Goldaracena, N.
    Kollmann, D.
    Hamar, M.
    Urbanelis, P.
    Ganesh, S.
    Adeyi, O.
    Grant, D.
    Selzner, N.
    Wasowicz, M.
    Selzner, M.
    TRANSPLANTATION, 2017, 101 (05) : 30 - 31
  • [28] Normothermic mechanical ex vivo perfusion of donor lungs Use of the Organ Care System Lung in preservation for transplantation
    Warnecke, Gregor
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2021, 35 (04): : 242 - 247
  • [29] Results after transplantation of normothermic ex vivo perfused donor hearts
    Schibilsky, D.
    Siepe, M.
    Beyersdorf, F.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2019, 33 (03): : 199 - 203
  • [30] Normothermic Human Ex Vivo Lung Perfusion (EVLP) for Improved Assessment of Extended Criteria Donor Lungs for Transplantation
    Cypel, M.
    Yeung, J.
    Liu, M.
    Chen, F.
    Karolak, W.
    Yasufuku, K.
    DePerrot, M.
    Pierre, A.
    Waddell, T.
    Chow, C-W
    Hutcheon, M.
    Chaparro, C.
    Singer, L. G.
    Keshavjee, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S126 - S126