RELIABILITY OF TIMBER STRUCTURES EXPOSED TO FIRE

被引:0
|
作者
Stepinac, Mislav [1 ]
Rajcic, Vlatka [1 ]
机构
[1] Univ Zagreb, Fac Civil Engn, Zagreb, Croatia
关键词
fire design; reliability; Eurocode; 5; timber structure; glulam beam;
D O I
10.14311/asfe.2015.045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Until recently, the fire resistance of buildings was based on the ISO standard curve. ISO standard curve used by the current norm is too simple, unrealistic and lead to uneconomic situations with no guarantee of security proportional to the invested money. Unlike the fire design of the steel, concrete or composite structures, methods for fire design of timber structures have been greatly simplified. Generally, it is not necessary to check the reduction of strength in the residual section because each increase of temperature is considered small and it is ignored. Global fire safety concept of timber structures is presented according to the recommendations from Eurocode norms. Special attention was given to natural fire design with two different methods of parametric exposure which are given in EN1995-1-2. This paper presents reliability analysis of a glulam beam in a case of fire. The limit-state functions for maximum bending stress of glulam beam in fire conditions are formed. Reliability indexes are obtained from the limit state of the beam exposed to 30 min fire. Reliability index in the Eurocodes (reliability class RC2) compared to the calculated reliability indexes obtained by the methods of reduced strength and effective section were described.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Stainless steel structures exposed to fire
    Ala-Outinen, Tiina
    Myllymäki, Jukka
    Baroudi, Djebar
    Oksanen, Tuuli
    2001, VTT Information Service, Vuorimiehentie 5, P.O.Box 1000, 02044, Finland
  • [32] Reliability Analysis of RC Beams Exposed to Fire
    Eamon, Christopher D.
    Jensen, Elin
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (02) : 212 - 220
  • [33] Timber encasement of steel structures as an alternative fire insulation
    Bihina, Gisèle
    Durif, Sébastien
    Bouchaïr, Abdelhamid
    Saulnier, Véronique
    Zhao, Bin
    ce/papers, 2021, 4 (2-4): : 1289 - 1296
  • [34] Strength and reliability of LVL timber composite in the conditions of fire temperatures
    Bednarek, Zoja
    Kamocka-Bronisz, Renata
    Ogrodnik, Pawel
    POZARNI OCHRANA 2010, 2010, : 31 - 34
  • [35] FIRE PROTECTION OF TIMBER STRUCTURES STRENGTHENED WITH FRP MATERIALS
    Zigler, Radek
    Pokorny, Marek
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2015, 24 (04):
  • [36] Fire Performance of Epoxied Connections in Heavy Timber Structures
    Gerard, R. B.
    Carradine, D. M.
    Moss, P. J.
    Buchanan, A. H.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 544 - +
  • [37] DESIGN OF FIRE RESISTANCE OF TIMBER STRUCTURES ACCORDING TO EUROCODE
    Baric, Ivana
    Stefic, Tihomir
    Takac, Stjepan
    ELECTRONIC JOURNAL OF THE FACULTY OF CIVIL ENGINEERING OSIJEK-E-GFOS, 2011, 3 : 14 - 22
  • [38] Reliability of steel structures in case of fire
    Boko, Ivica
    Peros, Bernardin
    Toric, Neno
    GRADEVINAR, 2010, 62 (05): : 389 - 400
  • [39] The influence of the fire source location on the load-bearing capacity of timber beam exposed to fire
    Kmiecik, Kamil
    FIRE AND ENVIRONMENTAL SAFETY ENGINEERING 2018 (FESE 2018), 2018, 247
  • [40] Analysis of the load-bearing capacity of timber members exposed to fire
    Kmiecik, Kamil
    Domanski, Tomasz
    FIRE AND ENVIRONMENTAL SAFETY ENGINEERING 2018 (FESE 2018), 2018, 247