Steady state performance of a single phase natural circulation loop with end heat exchangers

被引:4
|
作者
Rao, N. M. [1 ]
Maiti, B. [2 ]
Das, P. K. [2 ]
机构
[1] Rolta India Ltd, MIDC, Mumbai 400093, Maharashtra, India
[2] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
来源
关键词
steady state; natural circulation loop; end heat exchangers; overall effectiveness; optimum allocation;
D O I
10.1115/1.2928015
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present investigation, the steady state performance of a rectangular single phase natural circulation loop (NCL) with end heat exchangers is studied. One-dimensional governing equations are considered in developing the mathematical model. Analytical expressions are derived for the circulation rate and temperature profile. However, the individual performance parameters are to be computed iteratively as the equations are strongly coupled. A suitable iterative procedure is given to evaluate the important loop parameters such as steady state flow rate, and riser and downcomer temperatures. Few special cases are discussed where analytical expressions for circulation rate and temperature distribution can be obtained directly without any iterative procedure. It is also shown that both the hot and cold end heat exchangers should have equal conductance (UA) for maximization of circulation rate. This feature of NCL is identical with heat power cycle and can be explained in light of equipartition principle.
引用
收藏
页数:4
相关论文