Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry

被引:128
|
作者
Daubeney, PEF [1 ]
Pilkington, SN [1 ]
Janke, E [1 ]
Charlton, GA [1 ]
Smith, DC [1 ]
Webber, SA [1 ]
机构
[1] SOUTHAMPTON GEN HOSP,WESSEX CARDIOTHORAC CTR,SOUTHAMPTON SO9 4XY,HANTS,ENGLAND
来源
ANNALS OF THORACIC SURGERY | 1996年 / 61卷 / 03期
关键词
D O I
10.1016/0003-4975(95)01186-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Near-infrared spectroscopy is a potential tool for measuring adequacy of cerebral oxygenation during cardiac operations. The cerebral microcirculation is predominantly venous (by volume) and therefore regional cerebral oxygenation measured by near-infrared spectroscopy should reflect jugular bulb venous saturations. Methods. We compared simultaneous regional cerebral oxygenation and jugular bulb venous saturation measurements in 40 children (median age, 4.5 years; range, 2 weeks to 14.5 years) in the cardiac catheter laboratory (n = 29) and during cardiac operations (n = 11). Results. For all patients combined the correlation between regional cerebral oxygenation and jugular bulb venous saturation was 0.69 (p < 0.0001) and was similar for the two groups. For individual children undergoing cardiac operations excellent correlations were obtained (r = 0.78 to 0.96; median, 0.91). However, at low values of jugular bulb venous saturation, regional cerebral oxygenation tended to run high, whereas the converse was true for high values of jugular bulb venous saturation. Conclusions. These findings suggest that near-infrared spectroscopy may be a useful tool for assessing intravascular cerebral oxygenation during pediatric cardiac operations. Prospective studies of neurologic outcome will be required to establish the value of this technique for assessing the adequacy of cerebral protection.
引用
收藏
页码:930 / 934
页数:5
相关论文
共 50 条
  • [41] COMPARISON OF JUGULAR VENOUS O-2 SATURATION AND CEREBRAL O-2 SATURATION MEASURED BY NEAR-INFRARED SPECTROSCOPY
    AMORY, D
    CHEN, B
    BONNI, P
    CROUGHWELL, N
    LOWRY, E
    NEWMAN, M
    ANESTHESIOLOGY, 1995, 83 (3A) : A474 - A474
  • [42] Comparison of two commercially available near-infrared spectroscopy instruments for cerebral oximetry - Technical note
    Cho, H
    Nemoto, EM
    Sanders, M
    Fernandez, K
    Yonas, H
    JOURNAL OF NEUROSURGERY, 2000, 93 (02) : 351 - 354
  • [43] Evaluation of Cerebral Oxygenation in Neonates with Sepsis with Near-Infrared Spectroscopy
    Rallis, Dimitrios
    Karagianni, Paraskevi
    Milona, Eleni
    Pratsiou, Paraskevi
    Nikolaidis, Nikolaos
    Tsakalidis, Christos
    AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (05) : 419 - 427
  • [44] Near-infrared spectroscopy underestimates cerebral oxygenation in hemodialysis patients
    Shino Matsukawa
    Shinichi Kai
    Toshiyuki Mizota
    Journal of Anesthesia, 2019, 33 : 478 - 481
  • [45] Near-infrared spectroscopy (NIRS) measurements of cerebral oximetry in the neurovascular ICU
    Armonda, RA
    McGee, B
    Veznadaraglu, E
    Rosenwasser, RH
    Jefferson, RH
    CRITICAL CARE MEDICINE, 1999, 27 (12) : A72 - A72
  • [46] Near-infrared spectroscopy in the assessment of cerebral oxygenation at high altitude
    Imray, CHE
    Barnett, NJ
    Walsh, S
    Clarke, T
    Morgan, J
    Hale, D
    Hoar, H
    Mole, D
    Chesner, I
    Wright, AD
    WILDERNESS & ENVIRONMENTAL MEDICINE, 1998, 9 (04) : 198 - 203
  • [47] Near-infrared spectroscopy underestimates cerebral oxygenation in hemodialysis patients
    Matsukawa, Shino
    Kai, Shinichi
    Mizota, Toshiyuki
    JOURNAL OF ANESTHESIA, 2019, 33 (03) : 478 - 481
  • [48] The Accuracy of a Near-Infrared Spectroscopy Cerebral Oximetry Device and Its Potential Value for Estimating Jugular Venous Oxygen Saturation
    Ikeda, Keita
    MacLeod, David B.
    Grocott, Hilary P.
    Moretti, Eugene W.
    Ames, Warwick
    Vacchiano, Charles
    ANESTHESIA AND ANALGESIA, 2014, 119 (06): : 1381 - 1392
  • [49] Cerebral oxygenation measured by near-infrared spectroscopy correlates with arterial oxygenation only poorly in preterm infants - a strength of that technology?
    Urlesberger, Berndt
    Pichler, Gerhard
    ACTA PAEDIATRICA, 2018, 107 (01) : 174 - 174
  • [50] Changes in tissue oxygenation of the porcine liver measured by near-infrared spectroscopy
    El-Desoky, AEH
    Seifalian, A
    Cope, M
    Delpy, D
    Davidson, B
    LIVER TRANSPLANTATION AND SURGERY, 1999, 5 (03): : 219 - 226