Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential

被引:8
|
作者
McCollough, Cynthia H. [1 ]
McCollough, Shannon L. [1 ]
Schneider, Justine J. [1 ]
Moen, Taylor R. [1 ]
Weaver, Jayse M. [1 ]
Vrieze, Thomas J. [1 ]
Yu, Lifeng [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
ATTENUATION-BASED ESTIMATION; IMAGE QUALITY; PATIENT SIZE; PURPOSE;
D O I
10.1148/radiol.210860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The size-specific dose estimate (SSDE) is a patient-focused CT dose metric. However, published size-dependent conversion factors (f(size)) used to calculate SSDE were determined primarily by using phantoms; only eight to 15 patient data sets were used, all at 120 kV. Purpose: To determine the effect of different tube potentials on the water-equivalent diameter (WED) and SSDE for patient CT scans of the head, chest, and abdomen. Materials and Methods: This retrospective study used 250 noncontrast CT scans acquired between March 2013 and June 2017. Bony structures were segmented, and their CT numbers were modified to reflect bone attenuation at 70, 90, 110, 130, and 150 kV. Soft-tissue CT numbers were unchanged because of negligible energy dependence. f(size) was measured in anthropomorphic phantoms for each tube potential and fit to an exponential function. WED and SSDE were determined for each patient at all tube potentials, regression analysis was performed relative to the WED and SSDE at 120 kV, and mean differences relative to 120 kV were calculated. Results: In 250 patients (median age, 21.5 years; interquartile range, 44 years; 130 women), WED for all tube potentials was linearly related to the WED at 120 kV in all body regions (R-2 = 0.995-1.000). The effect of tube potential on WED was negligible for torso examinations (Cohen d < 0.05). In the head, a medium effect size was observed at 70 kV; however, the mean absolute difference in WED was small (-0.49 cm +/- 0.08 [standard deviation]; P< .001). For commonly used combinations of tube potential and patient size, the mean differences in SSDE at alternative tube potentials relative to SSDE at 120 kV were less than 5%. Conclusion: At noncontrast CT, published size-dependent conversion factors accurately determined size-specific dose estimates on 250 patient scans at five tube potentials other than 120 kV. (C) RSNA, 2022
引用
收藏
页数:8
相关论文
共 50 条
  • [31] An Investigation of Using a Single CT Image to Assess Size-Specific Dose Estimates (SSDE)
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E514 - E514
  • [32] Size-Specific Dose Estimates in Fetal Computed Tomography
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Minami, Kazuyuki
    Asada, Yasuki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 339 - 348
  • [33] Size-specific dose estimates in chest, abdomen, and pelvis CT examinations of pediatric patients
    Ozsoykal, Ismail
    Yurt, Aysegul
    Akgungor, Kadir
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2018, 24 (04): : 243 - 248
  • [34] Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan
    Tsai, H.
    Hwang, Y.
    Hu, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3643 - 3643
  • [35] LOCAL DRLS FOR PAEDIATRIC CT EXAMINATIONS BASED ON SIZE-SPECIFIC DOSE ESTIMATES IN KERMANSHAH, IRAN
    Mohammadbeigi, Ahmad
    Khoshgard, Karim
    Haghparast, Abbas
    Eivazi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (04) : 496 - 506
  • [36] Size-Specific Dose Estimates Correction in Adult and Pediatric Abdomen and Chest CT: A Retrospective Study
    Souza, G.
    Real, J.
    Froner, A.
    Thomaz, R.
    Marques da Silva, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 3072 - 3072
  • [37] Size-specific dose estimates (SSDE) for a prototype orthopeadic cone-beam CT system
    Richard, Samuel
    Packard, Nathan
    Yorkston, John
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [38] A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Dougherty, G.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [39] Patient size matters: Effect of tube current modulation on size-specific dose estimates (SSDE) and image quality in low-dose lung cancer screening CT
    Barreto, Izabella
    Verma, Nupur
    Quails, Nathan
    Olguin, Catherine
    Correa, Nathalie
    Mohammed, Tan-Lucien
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (04): : 87 - 94
  • [40] Estimating Water-Equivalent Diameter from CT Localizers and Applying It to Patient Data
    Burton, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E532 - E532