Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential

被引:8
|
作者
McCollough, Cynthia H. [1 ]
McCollough, Shannon L. [1 ]
Schneider, Justine J. [1 ]
Moen, Taylor R. [1 ]
Weaver, Jayse M. [1 ]
Vrieze, Thomas J. [1 ]
Yu, Lifeng [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
ATTENUATION-BASED ESTIMATION; IMAGE QUALITY; PATIENT SIZE; PURPOSE;
D O I
10.1148/radiol.210860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The size-specific dose estimate (SSDE) is a patient-focused CT dose metric. However, published size-dependent conversion factors (f(size)) used to calculate SSDE were determined primarily by using phantoms; only eight to 15 patient data sets were used, all at 120 kV. Purpose: To determine the effect of different tube potentials on the water-equivalent diameter (WED) and SSDE for patient CT scans of the head, chest, and abdomen. Materials and Methods: This retrospective study used 250 noncontrast CT scans acquired between March 2013 and June 2017. Bony structures were segmented, and their CT numbers were modified to reflect bone attenuation at 70, 90, 110, 130, and 150 kV. Soft-tissue CT numbers were unchanged because of negligible energy dependence. f(size) was measured in anthropomorphic phantoms for each tube potential and fit to an exponential function. WED and SSDE were determined for each patient at all tube potentials, regression analysis was performed relative to the WED and SSDE at 120 kV, and mean differences relative to 120 kV were calculated. Results: In 250 patients (median age, 21.5 years; interquartile range, 44 years; 130 women), WED for all tube potentials was linearly related to the WED at 120 kV in all body regions (R-2 = 0.995-1.000). The effect of tube potential on WED was negligible for torso examinations (Cohen d < 0.05). In the head, a medium effect size was observed at 70 kV; however, the mean absolute difference in WED was small (-0.49 cm +/- 0.08 [standard deviation]; P< .001). For commonly used combinations of tube potential and patient size, the mean differences in SSDE at alternative tube potentials relative to SSDE at 120 kV were less than 5%. Conclusion: At noncontrast CT, published size-dependent conversion factors accurately determined size-specific dose estimates on 250 patient scans at five tube potentials other than 120 kV. (C) RSNA, 2022
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent Diameter
    Leng, Shuai
    Shiung, Maria
    Duan, Xinhui
    Yu, Lifeng
    Zhang, Yi
    McCollough, Cynthia H.
    RADIOLOGY, 2015, 276 (01) : 184 - 190
  • [2] Size-Specific Dose Estimates Based on Water-Equivalent Diameter and Effective Diameter in Computed Tomography Coronary Angiography
    Xu, Jian
    Wang, Xiangquan
    Xiao, Huawei
    Xu, Jianguo
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9299 - 9305
  • [3] Determination of water-equivalent diameter (Dw) and size-specific dose estimates (SSDE) for adult patients in abdominal CT examinations
    El Mansouri, M'hamed
    Tahiri, Zakaria
    Talbi, Mohammed
    Nhila, Oussama
    Sekkat, Hamza
    Choukri, Abdelmajid
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024, 179 (5-6): : 634 - 641
  • [4] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397
  • [5] An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT
    Anam, Choirul
    Mahdani, Fahmi Rosydiansyah
    Dewi, Winda Kusuma
    Sutanto, Heri
    Triadyaksa, Pandji
    Haryanto, Freddy
    Dougherty, Geoff
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 313 - 323
  • [6] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548
  • [7] A SIMPLE METHOD FOR CALIBRATING PIXEL VALUES OF THE CT LOCALIZER RADIOGRAPH FOR CALCULATING WATER-EQUIVALENT DIAMETER AND SIZE-SPECIFIC DOSE ESTIMATE
    Anam, Choirul
    Fujibuchi, Toshioh
    Toyoda, Takatoshi
    Sato, Naoki
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (02) : 158 - 168
  • [8] Variability of Water-Equivalent Diameter (Dw) with Tube Potential of CT Scans
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent Diameter309 (vol 276, pg 184, 2015)
    Leng, Shuai
    Shiung, Maria
    Duan, Xinhui
    Yu, Lifeng
    Zhang, Yi
    McCollough, Cynthia H.
    RADIOLOGY, 2015, 277 (01) : 308 - 309
  • [10] A simple manual method to estimate water-equivalent diameter for calculating size-specific dose estimate in chest computed tomography
    Mihailidis, Dimitris
    Tsapaki, Virginia
    Tomara, Pelagia
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1117):