共 50 条
Environmental Analysis of Gas Chromatography-Mass Spectrometry Determination of Pyrethroids in Paris Polyphylla Samples Using Dispersive Liquid-Liquid Micro Extraction Coupled to Magnetic Nanoparticles
被引:0
|作者:
Tu, Yujiao
[1
]
Zhou, Yifang
[2
]
Yang, Yaling
[3
]
机构:
[1] Kunming Univ Sci & Technol, Fac Environm Sci & Engn, Kunming 650500, Yunnan, Peoples R China
[2] Kunming Univ, Dept Chem Sci & Technol, Kunming 650214, Yunnan, Peoples R China
[3] Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Yunnan, Peoples R China
来源:
关键词:
environmental analysis;
pollutants;
Paris polyphylla samples;
dispersive liquid-liquid microextraction;
hydrophobic magnetic nanoparticles;
gas chromatography-mass spectrometry;
SOLID-PHASE EXTRACTION;
PESTICIDE-RESIDUES;
WATER;
MICROEXTRACTION;
D O I:
暂无
中图分类号:
Q14 [生态学(生物生态学)];
学科分类号:
071012 ;
0713 ;
摘要:
Nowadays, gas chromatography (GC) continues to play an important role in the identification and quantification of ubiquitous pollutants in the environment A novel, rapid low-density solvent based dispersive liquid-liquid microextraction combined with magnetic nanoparticles has been developed for environmental analysis and pre-concentration of pyrethroids in parispolyphyllaprior to various classes of persistent organic contaminants in air, water, soils, sediments and biota. In this study, parispolyphylla samples were first treated with acetonitrile/water (80:20, v/v) which was then utilized as disperser solvent in the dispersive liquid-liquid microextraction process along with using 1-octanol as extractant in environment. In magnetic solid phase extraction approach, hydrophobic magnetic nanoparticles were used to retrieve and separate the 1-octanol in the dispersive liquid-liquid microextraction step. In fact the target of ecological solid phase extraction was the 1-octanol rather than the pyrethroids directly. Under the optimized conditions, the recoveries obtained for each pesticide ranged from 89.4 to 105.1% with relative standard deviations lower than 7.8%. Limit of detection ranged from 0.05 to 0.15 mu g kg(-1). The proposed ecological method was successfully used for the efficient determination of pyrethroids in real parispolyphylla samples in ecosystem.
引用
收藏
页码:1259 / 1269
页数:11