Quality assurance of individual radon measurements

被引:0
|
作者
Beck, TR [1 ]
Schwedt, J [1 ]
Hamel, P [1 ]
机构
[1] Fed Off Radiat Protect BfS, D-10318 Berlin, Germany
来源
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The 96/29/EURATOM guideline and its national transformations demand the application of radiation protection measures if the presence of radon and radon decay products leads to a significant increase in exposure of workers. The requirements of the aforementioned EURATOM guideline were met by the amendment to the German Radiation Protection Ordinance in 2001. Presently, a national guideline for the transformation of the legal rules into practice is being implemented to guarantee an effective but appropriate protection against natural radiation. The guideline regulates the responsibilities of the authorities as well as the setting-up of appropriate means and measures to be taken by the employers. Additionally, it will demand from the laboratories carrying out measurement tasks a program for quality assurance and the participation in measurement inter-comparisons. For the evaluation of laboratory inter-comparisons and for the authorization of personnel radon monitors, uniform accuracy criteria have been developed. Around the relevant limit of the measured potential alpha-energy exposure of 14 mJ h m(-3), an over- and under-estimation of the true value by a factor of 1.8 is accepted. Monitors for exposure to radon can be applied at workplaces with equilibrium factors within a range from 0.2 up to 0.7. Measurement uncertainty around the relevant limit of 6000 kBq h m(-3) is 20%.
引用
收藏
页码:731 / 739
页数:9
相关论文
共 50 条
  • [21] EPA QUALITY ASSURANCE GUIDANCE FOR METEOROLOGICAL MEASUREMENTS
    LOCKHART, TJ
    SIXTH JOINT CONFERENCE ON APPLICATIONS OF AIR POLLUTION METEOROLOGY, 1989, : 80 - 81
  • [22] Quality assurance audit of sonographic cervical measurements
    Shroth, L
    Zaidi, F
    Kelly, T
    Moore, T
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : S181 - S181
  • [23] QUALITY ASSURANCE FOR GAS-FLOW MEASUREMENTS
    ARNBERG, BT
    HILLBRAT.HS
    MECHANICAL ENGINEERING, 1974, 96 (05) : 76 - 76
  • [24] Dataset of quality assurance measurements of rhythmic movements
    Ziegelman, Liran
    Kosuri, Tanvi
    Hakim, Husain
    Zhao, Luqi
    Elshourbagy, Abdelwahab
    Mills, Kelly Alexander
    Harrigan, Timothy Patrick
    Hernandez, Manuel Enrique
    Brasi, James Robert
    DATA IN BRIEF, 2023, 50
  • [25] QUALITY-CONTROL OF MEASUREMENTS - MEASUREMENT ASSURANCE
    JUDISH, RM
    PROCEEDINGS OF THE IEEE, 1986, 74 (01) : 23 - 25
  • [26] Quality assurance of measurements in small product on firms
    Kulderknup, E
    Laaneots, R
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE INDUSTRIAL ENGINEERING - NEW CHALLENGES TO SME, 2002, : 104 - 107
  • [27] Raw wool measurements: Specification or quality assurance?
    Baxter, P
    WOOL TECHNOLOGY AND SHEEP BREEDING, 1996, 44 (01): : 29 - 38
  • [28] Quality assurance for the measurements and monitoring of radioactivity in the environment
    Betti, M
    de las Heras, LA
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2004, 72 (1-2) : 233 - 243
  • [29] Quality assurance and the evaluation of uncertainties in environmental measurements
    Gonzalez, LR
    CURRENT TRENDS IN RADIATION PROTECTION, 2004, : 127 - 138
  • [30] Quality assurance for a TLD based individual monitoring service
    Julius, HW
    van Dijk, JWE
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 1 - 6