Statistical limitations in proton imaging

被引:15
|
作者
Collins-Fekete, Charles-Antoine [1 ,2 ]
Dikaios, Nikolaos [3 ]
Royle, Gary [1 ]
Evans, Philip M. [2 ,3 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Gower St, London, England
[2] Natl Phys Lab, Chem Med & Environm Sci, Hampton Rd, Teddington, Middx, England
[3] Univ Surrey, Ctr Vis Speech & Signal Proc, Guildford, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 08期
基金
英国工程与自然科学研究理事会; 加拿大自然科学与工程研究理事会;
关键词
proton imaging; proton radiography; proton CT; noise; dose; spatial resolution; COMPUTED-TOMOGRAPHY; MONTE-CARLO; STOPPING-POWER; X-RAY; RANGE UNCERTAINTIES; SPATIAL-RESOLUTION; MULTIPLE COULOMB; PATH FORMALISM; LIKELY PATH; LUNG-TUMORS;
D O I
10.1088/1361-6560/ab7972
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Proton imaging is a promising technology for proton radiotherapy as it can be used for: (1) direct sampling of the tissue stopping power, (2) input information for multi-modality RSP reconstruction, (3) gold-standard calibration against concurrent techniques, (4) tracking motion and (5) pre-treatment positioning. However, no end-to-end characterization of the image quality (signal-to-noise ratio and spatial resolution, blurring uncertainty) against the dose has been done. This work aims to establish a model relating these characteristics and to describe their relationship with proton energy and object size. The imaging noise originates from two processes: the Coulomb scattering with the nucleus, producing a path deviation, and the energy loss straggling with electrons. The noise is found to increases with thickness crossed and, independently, decreases with decreasing energy. The scattering noise is dominant around high-gradient edge whereas the straggling noise is maximal in homogeneous regions. Image quality metrics are found to behave oppositely against energy: lower energy minimizes both the noise and the spatial resolution, with the optimal energy choice depending on the application and location in the imaged object. In conclusion, the model presented will help define an optimal usage of proton imaging to reach the promised application of this technology and establish a fair comparison with other imaging techniques.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Limitations of PET for imaging lymphoma
    Barrington, Sally F.
    O'Doherty, Michael J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (Suppl 1) : S117 - S127
  • [22] MEDICAL IMAGING - POSSIBILITIES AND LIMITATIONS
    BRENNECKE, R
    BIOMEDIZINISCHE TECHNIK, 1984, 29 (10): : 242 - 245
  • [23] The limitations of imaging response criteria
    Mehta, V. Ankit I.
    Sampson, John H.
    LANCET ONCOLOGY, 2012, 13 (11): : 1064 - 1065
  • [24] Limitations of PET for imaging lymphoma
    Sally F. Barrington
    Michael J. O'Doherty
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : S117 - S127
  • [25] LIMITATIONS OF IONOSPHERIC IMAGING BY TOMOGRAPHY
    YEH, KC
    RAYMUND, TD
    RADIO SCIENCE, 1991, 26 (06) : 1361 - 1380
  • [26] POTENTIAL AND LIMITATIONS OF PENUMBRAL IMAGING
    NUGENT, KA
    LUTHERDAVIES, B
    APPLIED OPTICS, 1986, 25 (06): : 1008 - 1014
  • [27] POSSIBILITIES AND LIMITATIONS OF INTRAVITAL IMAGING
    Hassan, Reham
    EXCLI JOURNAL, 2016, 15 : 872 - 874
  • [28] THEORETICAL LIMITATIONS OF TUMOR IMAGING
    GOODENOUGH, DJ
    ATKINS, FB
    NUCLEAR MEDICINE AND BIOLOGY, 1986, 13 (06): : 672 - 672
  • [29] Methods and Limitations of Subwavelength Imaging
    Neice, Andrew
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 163, 2010, 163 : 117 - 140
  • [30] ADVANTAGES AND LIMITATIONS OF DIGITAL IMAGING
    KOSTER, WG
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (692): : 813 - 813